zeiss_lsm_880

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
zeiss_lsm_880 [2025/01/06 00:19]
bioimaging
zeiss_lsm_880 [2025/07/29 16:55] (current)
bioimaging [Booking Rules]
Line 37: Line 37:
 </​html>​ </​html>​
  
-{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.+{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the GIMM server using the desktop link. 
  
-===== Booking Rules ===== 
-  - **Users** can book at maximum **8 hours per week** 
-  - This usage restriction does not apply for **weekends** and for working days **before 9:00** and **after 21:00** 
-  - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**. 
  
 ===== System components ===== ===== System components =====
Line 80: Line 77:
 The system should be always on, you only need to: The system should be always on, you only need to:
   * Turn on the HXP lamp   * Turn on the HXP lamp
-  * Turn on the computer+  * Turn on the computer ​(if needed)
   * Log into Windows with your Agendo credentials   * Log into Windows with your Agendo credentials
   * Start **ZEN**   * Start **ZEN**
Line 91: Line 88:
   * Leave all other used lasers and HXP lamp on   * Leave all other used lasers and HXP lamp on
   * Log off the computer   * Log off the computer
-  * Clean up immersion objectives+  * Clean up immersion objectives ​(gently wipe with optic cleaning paper and EtOH embedded paper)
 Else: Else:
   * Turn off the lasers on **ZEN**   * Turn off the lasers on **ZEN**
   * Turn off the HXP lamp   * Turn off the HXP lamp
-  * Clean up immersion objectives+  * Clean up immersion objectives ​(gently wipe with optic cleaning paper and EtOH embedded paper)
   * Exit the ZEN software   * Exit the ZEN software
-  * Shutdown ​the computer+  * Log off the computer
  
 ===== Microscope Turn On Procedure (after complete shutdown) ===== ===== Microscope Turn On Procedure (after complete shutdown) =====
Line 113: Line 110:
 ===== Microscope Turn Off Procedure (for complete shutdown) ===== ===== Microscope Turn Off Procedure (for complete shutdown) =====
  
-Please only shutdown the system if instructed to do so by the Bioimaging ​Unit.+Please only shutdown the system if instructed to do so by the Bioimaging ​Staff.
  
   * Turn off the lasers on **ZEN**   * Turn off the lasers on **ZEN**
zeiss_lsm_880.1736119160.txt.gz · Last modified: 2025/01/06 00:19 by bioimaging