bd_lsr_fortessa_2 [2024/01/19 15:13] flowcytometry [System overview] |
bd_lsr_fortessa_2 [2025/02/14 19:29] (current) flowcytometry |
||
---|---|---|---|
Line 1: | Line 1: | ||
<html> | <html> | ||
- | <img src="/facility/flowcytometry/lib/exe/fetch.php?media=fortessa_2_name_wiki.png"> | + | <img src="/facility/flowcytometry/lib/exe/fetch.php?media=fortessa_name_wiki_gimm.png"> |
<table style="border:0px solid white;"> | <table style="border:0px solid white;"> | ||
<tr style="border:0px solid white;"> | <tr style="border:0px solid white;"> | ||
<td style="border:0px solid white;"> | <td style="border:0px solid white;"> | ||
- | <a href="/facility/flowcytometry/lib/exe/fetch.php?media=fortessa_2_wiki_2.jpg"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=fortessa_2_wiki_2.jpg" width=300></a> | + | <img src="/facility/flowcytometry/lib/exe/fetch.php?media=fortessa_2_wiki.png"WIDTH=300> |
<td style="border:0px solid white;"> <p style="line-height:1.8"> | <td style="border:0px solid white;"> <p style="line-height:1.8"> | ||
- | <b>Location</b>: <a href="/facility/flowcytometry/lib/exe/fetch.php?media=flow_cytometry_map.jpg">Room P2-A-49</a> (<img src="/facility/flowcytometry/lib/exe/fetch.php?media=telephone_icon.gif" width=15> 47224) <br> | + | <b>Location</b>: Lisbon Site, Room P2-A-49</a> (<img src="/facility/flowcytometry/lib/exe/fetch.php?media=telephone_icon.gif" width=15> 47224) <br> |
<b>Manufacturer</b>: <a href="http://www.bdbiosciences.com/eu/home" target="_blank">BD Biosciences</a><br> | <b>Manufacturer</b>: <a href="http://www.bdbiosciences.com/eu/home" target="_blank">BD Biosciences</a><br> | ||
<b>Model</b>: <a href="https://www.bdbiosciences.com/en-us/products/instruments/flow-cytometers/research-cell-analyzers/bd-lsrfortessa" target="_blank">LSRFortessa</a><br> | <b>Model</b>: <a href="https://www.bdbiosciences.com/en-us/products/instruments/flow-cytometers/research-cell-analyzers/bd-lsrfortessa" target="_blank">LSRFortessa</a><br> | ||
- | <b>Nickname</b>: "Fortessa 2"<br> | + | <b>Nickname</b>: "Fortessa"<br> |
<b>Software</b>: FACSDiva 6.2<br> | <b>Software</b>: FACSDiva 6.2<br> | ||
<b>Year</b>: 2010 <br> | <b>Year</b>: 2010 <br> | ||
Line 16: | Line 16: | ||
  <br> |   <br> | ||
  <br> |   <br> | ||
- | → <a href="https://my.agendoscience.com/calendar/?id=NDFjYWxlbmRhcnM=" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=booking.png"> BD LSRFortessa 2 Booking</a> | + | → <a href="https://europe.agendoscience.com/calendar/?id=NDFjYWxlbmRhcnM=" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=booking.png"> BD LSRFortessa Booking</a> |
<br> | <br> | ||
- | → <a href="/facility/flowcytometry/doku.php?id=bd_lsrfortessa_2_usage"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=statistics.png"> BD LSRFortessa 2 Usage Statistics</a> | + | → <a href="/facility/flowcytometry/doku.php?id=bd_lsrfortessa_2_usage"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=statistics.png"> BD LSRFortessa Usage Statistics</a> |
<br> | <br> | ||
- | → <a href="https://imm.medicina.ulisboa.pt/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_brochure.pdf" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=brochure.png"> BD LSRFortessa 2 Brochure</a> | + | → <a href="https://imm.medicina.ulisboa.pt/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_brochure.pdf" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=brochure.png"> BD LSRFortessa Brochure</a> |
  </p> |   </p> | ||
</td> | </td> | ||
Line 26: | Line 26: | ||
</table> | </table> | ||
</html> | </html> | ||
- | {{:info.gif|}} **Next Scheduled Maintenances**: 22 June and 14 December | + | {{:info.gif|}} **Next Scheduled Maintenances**: 26 June and 11 December |
===== System overview ===== | ===== System overview ===== | ||
- | {{ :flow_cell_sit_sample.png?0x300|}} The BD LSRFortessa 2 //cell analyzer// is a benchtop digital flow cytometer equipped with a fixed-alignment flow cell that is gel-coupled to the collection optics. It has four spatially separated lasers - 405 nm, 488 nm, 561 nm and 640 nm. Its primary function is to characterize complex populations of cells. Individual cells pass single file through a stream, which is interrogated by the three lasers with the emitted light being detected by photomultiplier (PMT) tubes. The system electronics calculates the time it takes a single cell to pass through each laser intercept and assigns the signal of each PMT to the appropriate cell. Besides fluorescence, the physical properties of the cell are also analyzed with side scatter (SSC), which reflects the internal complexity of a cell and forward scatter (FSC), which is roughly proportional to cell size. The sample flow rate can be set to low, medium and high values, which correspond approximately to 12, 35 and 60 μl/minute, respectively. | + | {{ :flow_cell_sit_sample.png?0x300|}} The BD LSRFortessa //cell analyzer// is a benchtop digital flow cytometer equipped with a fixed-alignment flow cell that is gel-coupled to the collection optics. It has four spatially separated lasers - 405 nm, 488 nm, 561 nm and 640 nm. Its primary function is to characterize complex populations of cells. Individual cells pass single file through a stream, which is interrogated by the three lasers with the emitted light being detected by photomultiplier (PMT) tubes. The system electronics calculates the time it takes a single cell to pass through each laser intercept and assigns the signal of each PMT to the appropriate cell. Besides fluorescence, the physical properties of the cell are also analyzed with side scatter (SSC), which reflects the internal complexity of a cell and forward scatter (FSC), which is roughly proportional to cell size. The sample flow rate can be set to low, medium and high values, which correspond approximately to 12, 35 and 60 μl/minute, respectively. |
- | The LSRFortessa 2 is equipped with a **High Throughput Sampler (HTS)**, which allows the automated acquisition of samples from 96 and 384 well plates. | + | The LSRFortessa is equipped with a **High Throughput Sampler (HTS)**, which allows the automated acquisition of samples from 96 and 384 well plates. |
Line 38: | Line 38: | ||
* Multicolor analysis of up to 13 parameters | * Multicolor analysis of up to 13 parameters | ||
- | **If you need multicolor analysis of more than 13 parameters, check the [[bd_lsr_fortessa_x20|BD LSRFortessa X-20]], the [[bd_facs_symphony_a5_se|BD FACSymphony A5 SE]] or the [[cytek_aurora|CYTEK Aurora]].** | + | If you need multicolor analysis of more than 13 parameters, check the [[bd_lsr_fortessa_x20|BD LSRFortessa X20]], the [[bd_facs_symphony_a5_se|BD FACSymphony A5 SE]] or the [[cytek_aurora|CYTEK Aurora]] in <html><span style="color:blueviolet;font-size:100%;">Lisbon site</span></html> and the [[cytek_aurora_oeiras|CYTEK Aurora]] in <html><span style="color:yellowgreen;font-size:100%;">Oeiras site</span></html>. |
- | + | ||
- | **If you only need to analyse 4 parameters, check also the [[bd_accuri_c6|BD Accuri C6 Plus]].** | + | |
- | + | ||
===== Configuration ===== | ===== Configuration ===== | ||
- | {{:bd_lsrfortessa_2_configuration_(new).png?900|}} | + | <html><img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_2_configuration_(new).png"WIDTH=900></html> |
===== Fluorophores Compatibility ===== | ===== Fluorophores Compatibility ===== | ||
- | {{:bd_lsrfortessa_2_fluorophores_wiki_new.png?900|}} | + | <html><img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_2_fluorophores_wiki_new.png"WIDTH=900><br><br> |
- | \\ | + | <img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_2_additional_filters.png"WIDTH=360><br><br> |
- | {{::bd_lsrfortessa_2_additional_filters.png?360|}} | + | <img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_2_405.png"WIDTH=700><br> |
- | \\ | + | <img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_x-20_488.png"WIDTH=700><br> |
- | \\ | + | <img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_x-20_561.png"WIDTH=700><br> |
- | {{::bd_lsrfortessa_2_405.png?700|}} | + | <img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_lsrfortessa_2_640.png"WIDTH=700> |
- | \\ | + | </html> |
- | {{::bd_lsrfortessa_x-20_488.png?700|}} | + | |
- | \\ | + | |
- | {{::bd_lsrfortessa_x-20_561.png?700|}} | + | |
- | \\ | + | |
- | {{::bd_lsrfortessa_2_640.png?700|}} | + | |
===== Useful Links when Preparing your Experiment ===== | ===== Useful Links when Preparing your Experiment ===== | ||
- | * [[prepare_samples|{{how_to_prepare_samples_for_flow_cytometry.png}}]] | + | * <html><a href="https://imm.medicina.ulisboa.pt/facility/flowcytometry/lib/exe/fetch.php?media=sop.ucf.005_-_how_to_prepare_samples_for_flow_cytometry.pdf" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=how_to_prepare_samples_for_flow_cytometry.png" WIDTH=400></a></html> |
* <html><a href="http://www.bdbiosciences.com/en-us/applications/research-applications/multicolor-flow-cytometry/product-selection-tools/spectrum-viewer" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_spectrum_viewer.png" WIDTH=300></a></html> | * <html><a href="http://www.bdbiosciences.com/en-us/applications/research-applications/multicolor-flow-cytometry/product-selection-tools/spectrum-viewer" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_spectrum_viewer.png" WIDTH=300></a></html> | ||
* <html><a href="http://www.bdbiosciences.com/en-us/applications/research-applications/multicolor-flow-cytometry/product-selection-tools/spectrum-viewer" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_research_cloud.png" WIDTH=300></a></html> | * <html><a href="http://www.bdbiosciences.com/en-us/applications/research-applications/multicolor-flow-cytometry/product-selection-tools/spectrum-viewer" target="_blank"><img src="/facility/flowcytometry/lib/exe/fetch.php?media=bd_research_cloud.png" WIDTH=300></a></html> | ||
Line 81: | Line 72: | ||
Available 7 days a week, 24 hours a day for trained researchers. | Available 7 days a week, 24 hours a day for trained researchers. | ||
- | Please check the {{ ::sop.ucf.004_-_ucf_imm_user_guidelines.pdf |User Guidelines}} for detailed information. | + | Please check the <html><a href="https://imm.medicina.ulisboa.pt/facility/flowcytometry/lib/exe/fetch.php?media=sop.ucf.004_-_ucf_imm_user_guidelines_.pdf" target="_blank"> User Guidelines</a></html> for detailed information. |
---- | ---- | ||