This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
bd_facs_symphony_a5_se [2024/08/28 16:34] flowcytometry [System overview] |
bd_facs_symphony_a5_se [2025/04/15 17:20] (current) flowcytometry |
||
---|---|---|---|
Line 25: | Line 25: | ||
</table> | </table> | ||
</html> | </html> | ||
- | {{:info.gif|}} **Next Scheduled Maintenances**: | + | {{:info.gif|}} **Next Scheduled Maintenances**:14 April |
===== System overview ===== | ===== System overview ===== | ||
{{ :flow_cell_sit_sample.png?0x300|}} | {{ :flow_cell_sit_sample.png?0x300|}} | ||
{{ :facsymphony_detectors.png?0x200|}} The BD FACSymphony™ A5 SE allows for high-parameter spectral flow cytometry. It enables you to gain full visible spectrum coverage to collect all light emitted without the need for filter changes, increasing dye flexibility and number of simultaneous colors. It also allows for autofluorescence unmixing, that may enable the resolution of difficult cells and populations. | {{ :facsymphony_detectors.png?0x200|}} The BD FACSymphony™ A5 SE allows for high-parameter spectral flow cytometry. It enables you to gain full visible spectrum coverage to collect all light emitted without the need for filter changes, increasing dye flexibility and number of simultaneous colors. It also allows for autofluorescence unmixing, that may enable the resolution of difficult cells and populations. | ||
+ | \\ | ||
\\ | \\ | ||
\\ | \\ | ||
Line 35: | Line 36: | ||
* Five lasers with ultra-violet (349nm), violet (405 nm), blue (488 nm), yellow-green (561 nm) and red (640 nm) | * Five lasers with ultra-violet (349nm), violet (405 nm), blue (488 nm), yellow-green (561 nm) and red (640 nm) | ||
* Enables both spectral unmixing and compensation workflows | * Enables both spectral unmixing and compensation workflows | ||
+ | \\ | ||
\\ | \\ | ||
If you need high parameter cell analysis and a high-throughput sampler, check also the [[cytek_aurora|CYTEK Aurora]] in <html><span style="color:blueviolet;font-size:100%;">Lisbon site</span></html> and the [[cytek_aurora_oeiras|CYTEK Aurora]] in <html><span style="color:yellowgreen;font-size:100%;">Oeiras site</span></html>. | If you need high parameter cell analysis and a high-throughput sampler, check also the [[cytek_aurora|CYTEK Aurora]] in <html><span style="color:blueviolet;font-size:100%;">Lisbon site</span></html> and the [[cytek_aurora_oeiras|CYTEK Aurora]] in <html><span style="color:yellowgreen;font-size:100%;">Oeiras site</span></html>. |