User Tools

Site Tools


zeiss_lsm_900

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
zeiss_lsm_900 [2025/12/08 18:05]
bioimaging
zeiss_lsm_900 [2025/12/12 14:56] (current)
bioimaging [Filtersets (for eyepieces)]
Line 6: Line 6:
 <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lsm_900.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lsm_900.jpg"​ width=300></​a>​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lsm_900.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lsm_900.jpg"​ width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ [Oeiras] Room 0B03<​br> ​+<​b>​Location</​b>: ​<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=bartolomeu_dias_wing_2025_-_zeiss_lsm_900.png">​[Oeiras] Room 0B03</a><​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​
 <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​confocal-microscopes/​lsm-900-with-airyscan-2.html">​LSM 900 with Airyscan 2</​a><​br>​ <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​confocal-microscopes/​lsm-900-with-airyscan-2.html">​LSM 900 with Airyscan 2</​a><​br>​
Line 51: Line 51:
  
 ^  LASER  ^  Wavelength ​ ^  Maximum Power  ^ ^  LASER  ^  Wavelength ​ ^  Maximum Power  ^
-|  <fc #8200c8>​405 ​(violet)</​fc> ​ ​| ​ 405 nm  ​| ​ 15 mW  | +|  Violet  ​|  <fc #a600ff>​405 ​nm</​fc> ​ |  15 mW  | 
-|  <fc #​00f7ff>​488 ​(blue)</​fc> ​ |  ​488 nm  |  13 mW  | +|  Blue  ​|  <fc #​00f7ff>​488 ​nm</​fc> ​ |  ​13 mW  | 
-|  <fc #c6ff00>561 (yellow-green)</​fc> ​ |  ​561 nm  |  ​13 mW  | +|  Yellow-Green ​ |  <fc #​c6ff00>​561 ​nm</​fc> ​ ​| ​ 13 mW  | 
-|  <fc #ff2600>640 (red)</​fc> ​ |  640 nm  |  ​10 mW  |+|  Red  ​|  <fc #ff2600>640 nm</​fc> ​ |  10 mW  | 
 + 
 +==== LEDs (for eyepieces==== 
 + 
 +^  Line  ^  Wavelength ​ ^ 
 +|  UV  |  <fc #​be00cc>​385 nm</​fc>  ​
 +|  ​B  |  <fc #​00c0ff>​475 ​nm</​fc> ​ 
 +|  ​G  |  <fc #​b3ff00>​555 nm</​fc> ​ | 
 +|  R  ​|  <fc #ff4f00>630 nm</​fc> ​ | 
 + 
 +==== Filtersets ​(for eyepieces==== 
 + 
 +^  Filterset ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^  Reference ​ ^ 
 +|  Green  |  450-490 nm  |  493 nm  |  <fc #​4aff00>​500-550 nm</​fc> ​ |  ​[[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​filterAssistant/​filtersets/​000000-1031-346|FS38]] ​ | 
 +|  Orange-Red ​ |  533-558 nm  |  570 nm  |  <fc #​ffad00>​570-640 nm</​fc> ​ ​|  ​[[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1114-101&​o=|FS43]] ​ | 
 +|  Blue  |  370-410 nm  |  420 nm  |  <fc #​0046ff>​430-470 nm</​fc> ​ |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​filterAssistant/​filtersets/​489096-9100-000|FS96HE]] ​ | 
  
 ==== Objectives ==== ==== Objectives ====
 +
 ^  Magnification ​  ​^ ​ Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ ^  Magnification ​  ​^ ​ Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
-|  <fc #e94543>​5x</​fc> ​ |  EC Plan-Neofluar ​ |  Air  |  0.16  |  18.5  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ |+|  <fc #df2b37>​5x</​fc> ​ |  EC Plan-Neofluar ​ |  Air  |  0.16  |  18.5  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ |
 |  <fc #​fef042>​10x</​fc> ​ |  Plan-Apochromat ​ |  Air  |  0.45  |  2  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​420640-9900-000/​Objective-Plan-Apochromat-10x-0.45-M27|420640-9900-000]] ​ | |  <fc #​fef042>​10x</​fc> ​ |  Plan-Apochromat ​ |  Air  |  0.45  |  2  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​420640-9900-000/​Objective-Plan-Apochromat-10x-0.45-M27|420640-9900-000]] ​ |
 |  <fc #​0aa05c>​20x</​fc> ​ |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​420650-9903-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9903-000]] ​ | |  <fc #​0aa05c>​20x</​fc> ​ |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​420650-9903-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9903-000]] ​ |
Line 64: Line 81:
 |  <fc #​2c80c0>​63x</​fc> ​ |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ | |  <fc #​2c80c0>​63x</​fc> ​ |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ |
  
-==== LEDs (Ocular) ​====+===== How to start your session =====
  
-^  Line  ^  Wavelength ​ ^ +If you are the **first user** of the day:
-|  <fc #​6f0077>​UV</​fc> ​ |  385 nm  | +
-|  <fc #​00c0ff>​B</​fc> ​ |  475 nm  | +
-|  <fc #​b3ff00>​G</​fc> ​ |  555 nm  | +
-|  <fc #​ff4f00>​R</​fc> ​ |  630 nm  |+
  
-==== Emission Filters ==== +  * Turn off the power bar 
- +{{::Oeiras_LSM900_powerbar.png?200|}} 
-^  Filter name  ^  Transmission(nm) ​ ^  Reference ​ ^ +  ​* Turn off Components 
-|  BFP  |  450/​40 ​ | [[https://​www.fpbase.org/​spectra/?​s=2666,​2668,​2667,​2055&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength|96 HE]] | +  ​* Turn off Systems 
-|  GFP  |  425/​50 ​ | [[https://www.fpbase.org/​spectra/​?s=1484,​1495,​1485,​2057&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength|38 HE]] +  ​* Turn on the computer 
- Alexa 546  |  LP590  | [[https://​www.fpbase.org/​spectra/?​s=1530,​1533,​1536,​2059&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength|15]] | +  ​* Turn on Systems 
- Cy5  |  690/​50 ​ | [[https://​www.fpbase.org/​spectra/?​s=1547,​1550,​1543,​2068&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength|50]] | +  ​* Turn on Components 
- DIC  |  <​800 ​ | - | +  * Turn on the incubation ​module ​(if needed - turn on 30 mins before acquiring) 
- mPlum  |  629/​62 ​ | [[https://​www.fpbase.org/​spectra/?​s=2620,​2618,​2619,​2069&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength|64 HE]] | +{{::Oeiras_LSM900_incubation.png?200|}} 
- Quad  |  425/​514/​592/​709 ​ | [[https://​www.fpbase.org/​spectra/?​s=2657,​2601,​2602,​2658,​2577&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength|90 HE]] | +  * Turn on the power bar
- +
-===== How to start your session ===== +
- +
-The system should be always ​on, you only need to: +
-  * If incubation ​is needed ​(turn on 30 mins before acquiring)+
-    * Turn the powerbar off +
-{{::Oeiras_LSM900_powerbar.png?300|}} +
-    * Turn the incubation controller ​on +
-{{::​Oeiras_LSM900_incubation.png?​300|}} +
-    * Turn the powerbar on+
   * Log into Windows with your Agendo credentials   * Log into Windows with your Agendo credentials
   * Start **ZEN**   * Start **ZEN**
- 
-===== How to end your session ===== 
- 
-If there is another user for this microscope in the __next hour__: 
-  * Exit ZEN, leave the lasers on 
-  * Log off the computer 
-  * Clean up immersion objectives (gently wipe with optic cleaning paper and EtOH embedded paper) 
 Else: Else:
-  * Turn off the lasers in **ZEN** 
-  * Clean up immersion objectives (gently wipe with optic cleaning paper and EtOH embedded paper) 
-  * Exit ZEN 
-  * Log off the computer 
- 
-===== Microscope Turn On Procedure (after complete shutdown) ===== 
- 
-If the system is completely off, please follow this procedure: 
- 
-  * Turn the Laser key 
-{{::​oeiras_900_turningon1.jpg?​300|}} 
-  * Turn on the ''​SYSTEM''​ and ''​COMPONENTS''​ switches 
-{{::​oeiras_900_turningon2.jpg?​300|}} 
-  * Turn on the ''​Power bar''​ (on the back right-hand side of the microscope) 
-{{::​oeiras_lsm900_powerbar.png?​300|}} 
-  * Turn on the computer 
   * Log into Windows with your Agendo credentials   * Log into Windows with your Agendo credentials
-  * Start the **ZEN** ​software+  * Start **ZEN**
  
-===== Microscope Turn Off Procedure (for complete shutdown) ​===== +===== How to end your session ​=====
- +
-Please only shutdown the system if instructed to do so by the Bioimaging staff.+
  
-  * Turn off the lasers in **ZEN*+If there is another user: 
-  * Exit ZEN +  ​Clean up immersion objectives ​ 
-  * Shutdown ​the computer +  * Exit the ZEN software ​ 
-  * Turn off the ''​Power Bar'' ​(on the back right-hand side of the microscope) +  * Log off the computer  
-  * Turn off the ''​SYSTEM''​ and ''​COMPONENTS''​ switches +  * Turn off incubation module ​(if used)  
-  * Turn off the Laser key+If you are the **last user** ​of the day:  
 +  * Clean up immersion objectives  
 +  * Exit the ZEN software ​ 
 +  * Turn off the computer ​ 
 +  * Turn off incubation module (if used) 
  
 ---- ----
  
 [[resources|Back to the Equipment page]] [[resources|Back to the Equipment page]]
zeiss_lsm_900.1765213525.txt.gz · Last modified: 2025/12/08 18:05 by bioimaging