User Tools

Site Tools


zeiss_celldiscoverer_7

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
zeiss_celldiscoverer_7 [2026/02/14 13:28]
bioimaging
zeiss_celldiscoverer_7 [2026/04/17 01:14] (current)
bioimaging
Line 10: Line 10:
 <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​imaging-systems/​celldiscoverer-7.html">​Celldiscoverer 7 with LSM 900</​a><​br>​ <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​imaging-systems/​celldiscoverer-7.html">​Celldiscoverer 7 with LSM 900</​a><​br>​
 <​b>​Nickname</​b>:​ "​CD7"<​br>​ <​b>​Nickname</​b>:​ "​CD7"<​br>​
-<​b>​Software</​b>:​ ZEN 3.12 (ZEN celldiscoverer)<​br>​+<​b>​Software</​b>:​ ZEN 3.13 (ZEN celldiscoverer)<​br>​
 <​b>​Year</​b>:​ 2022 <br> <​b>​Year</​b>:​ 2022 <br>
 <​b>​SN</​b>:​ 4648000055<​br>​ <​b>​SN</​b>:​ 4648000055<​br>​
Line 88: Line 88:
  
 ^  Position ​ ^  Filterset ​ ^  Dichroic ​ ^  Emission ​ ^  Reference ​ ^ ^  Position ​ ^  Filterset ​ ^  Dichroic ​ ^  Emission ​ ^  Reference ​ ^
-|  1  |  RQBS  |  405 nm  |  <fc #​5400ff>​410-440 nm</​fc> ​ |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​filterAssistant/​filtersets/​489090-9100-000|FS90HE]] ​ |+|  1  |  RQBS  |  405 nm  |  <fc #​5400ff>​410-440 nm</​fc> ​ |  [[https://​www.micro-shop.zeiss.com/​en/​us/​fluorescenceAssistant/​filtersets/​489090-9110-000|FS90HE]] ​ |
 |  :::  |  :::  |  493 nm  |  <fc #​1fff00>​499-529 nm</​fc> ​ |  :::  | |  :::  |  :::  |  493 nm  |  <fc #​1fff00>​499-529 nm</​fc> ​ |  :::  |
 |  :::  |  :::  |  575 nm  |  <fc #​ffd900>​580-605 nm</​fc> ​ |  :::  | |  :::  |  :::  |  575 nm  |  <fc #​ffd900>​580-605 nm</​fc> ​ |  :::  |
 |  :::  |  :::  |  653 nm  |  <fc #​ef0000>​659-759 nm</​fc> ​ |  :::  | |  :::  |  :::  |  653 nm  |  <fc #​ef0000>​659-759 nm</​fc> ​ |  :::  |
-|  2  |  RTBS  |  450 nm  |  <fc #​009cff>​455-479 nm</​fc> ​ |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​filterAssistant/​filtersets/​489091-9110-000|FS91HE]] ​ |+|  2  |  RTBS  |  450 nm  |  <fc #​009cff>​455-479 nm</​fc> ​ |  [[https://​www.micro-shop.zeiss.com/​en/​us/​fluorescenceAssistant/​filtersets/​489091-9110-000|FS91HE]] ​ |
 |  :::  |  :::  |  538 nm  |  <fc #​b3ff00>​543-568 nm</​fc> ​ |  :::  | |  :::  |  :::  |  538 nm  |  <fc #​b3ff00>​543-568 nm</​fc> ​ |  :::  |
 |  :::  |  :::  |  610 nm  |  <fc #​ff0000>​615-760 nm</​fc> ​ |  :::  | |  :::  |  :::  |  610 nm  |  <fc #​ff0000>​615-760 nm</​fc> ​ |  :::  |
-|  3  |  RTBS  |  405 nm  |  <fc #​5400ff>​410-440 nm</​fc> ​ |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​filterAssistant/​filtersets/​489092-9110-000|FS92HE]] ​ |+|  3  |  RTBS  |  405 nm  |  <fc #​5400ff>​410-440 nm</​fc> ​ |  [[https://​www.micro-shop.zeiss.com/​en/​us/​fluorescenceAssistant/​filtersets/​489092-9110-000|FS92HE]] ​ |
 |  :::  |  :::  |  493 nm  |  <fc #​46ff00>​499-549 nm</​fc> ​ |  :::  | |  :::  |  :::  |  493 nm  |  <fc #​46ff00>​499-549 nm</​fc> ​ |  :::  |
 |  :::  |  :::  |  610 nm  |  <fc #​ff0000>​616-761 nm</​fc> ​ |  :::  | |  :::  |  :::  |  610 nm  |  <fc #​ff0000>​616-761 nm</​fc> ​ |  :::  |
zeiss_celldiscoverer_7.1771072137.txt.gz ยท Last modified: 2026/02/14 13:28 by bioimaging