<b>Model</b>: <a href="https://www.zeiss.com/microscopy/en/products/imaging-systems/celldiscoverer-7.html">Celldiscoverer 7 with LSM 900</a><br> | <b>Model</b>: <a href="https://www.zeiss.com/microscopy/en/products/imaging-systems/celldiscoverer-7.html">Celldiscoverer 7 with LSM 900</a><br> | ||
<b>Nickname</b>: "CD7"<br> | <b>Nickname</b>: "CD7"<br> | ||
- | <b>Software</b>: ZEN 3.8 (ZEN celldiscoverer)<br> | + | <b>Software</b>: ZEN 3.12 (ZEN celldiscoverer)<br> |
<b>Year</b>: 2022 <br> | <b>Year</b>: 2022 <br> | ||
<b>SN</b>: 4648000055<br> | <b>SN</b>: 4648000055<br> | ||
Line 40: | Line 40: | ||
* [[https://www.zeiss.com/microscopy/en/resources/insights-hub/life-sciences/the-smart-microscope-for-automated-workflows-celldiscoverer-7-with-lsm-900.html|ZEISS Webinar: LSM 980 Airyscan 2 Multiplex mode]] | * [[https://www.zeiss.com/microscopy/en/resources/insights-hub/life-sciences/the-smart-microscope-for-automated-workflows-celldiscoverer-7-with-lsm-900.html|ZEISS Webinar: LSM 980 Airyscan 2 Multiplex mode]] | ||
- | {{:warning.png?25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. | + | {{:warning.png?25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the GIMM server using the desktop link. |
- | ===== Booking Rules ===== | ||
- | - **Users** can book at maximum **8 hours per week** | ||
- | - This usage restriction does not apply for **weekends** and for working days **before 9:00** and **after 21:00** | ||
- | - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**. | ||
===== System components ===== | ===== System components ===== | ||
Line 106: | Line 103: | ||
* Activate the CD7 by pressing the "Standby" button (to the left of the touch panel) | * Activate the CD7 by pressing the "Standby" button (to the left of the touch panel) | ||
{{::cd7_standby.png?250|}} | {{::cd7_standby.png?250|}} | ||
- | * Turn on the computer | + | * Turn on the computer (if needed) |
* Log into Windows with your Agendo credentials | * Log into Windows with your Agendo credentials | ||
* Start **ZEN** | * Start **ZEN** | ||
Line 121: | Line 118: | ||
* Turn off the lasers on **ZEN** | * Turn off the lasers on **ZEN** | ||
* Exit the ZEN software | * Exit the ZEN software | ||
- | * Shutdown the computer | + | * Log off the computer |
* Press the "Standby" button (to the left of the touch panel). | * Press the "Standby" button (to the left of the touch panel). | ||
Line 138: | Line 135: | ||
===== Microscope Turn Off Procedure (for complete shutdown) ===== | ===== Microscope Turn Off Procedure (for complete shutdown) ===== | ||
- | Please only shutdown the system if instructed to do so by the Bioimaging Unit. | + | Please only shutdown the system if instructed to do so by the Bioimaging Staff. |
* Close the main valve of the CO2 tank (if used) | * Close the main valve of the CO2 tank (if used) |