User Tools

Site Tools


zeiss_cell_observer

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
zeiss_cell_observer [2024/01/28 12:31]
bioimaging [Microscope overview]
zeiss_cell_observer [2025/01/14 16:34] (current)
bioimaging [Microscope overview]
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_name_new.png">​+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lisbon_zeiss_cell_observer_name_gimm_2024.png">​
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wiki_2022.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wiki_2022.png" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wiki_2024.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wiki_2024.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_map_new_p2a24.png">​Room P2-A-24</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) <​br> ​+<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_map_new_p2a24.png">​[Lisbon] ​Room P2-A-24</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​
 <​b>​Model</​b>:​ Axio Observer<​br>​ <​b>​Model</​b>:​ Axio Observer<​br>​
Line 15: Line 15:
 &nbsp <br> &nbsp <br>
 Data will be deleted after: <b>15 days</​b>​ Data will be deleted after: <b>15 days</​b>​
-&nbsp <br> 
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
Line 30: Line 29:
 {{  :​widefield_lightpath.png?​0x300}}The Zeiss Cell Observer is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging with fast acquisition speeds. It is equipped with a large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. The stage is furthermore equipped with a piezo for fast Z displacement. You can choose between a HXP metal halide lamp or fast-switching LEDs for illumination. Its cooled [[https://​asset-downloads.zeiss.com/​catalogs/​download/​mic/​a8e5b4d7-25f6-4069-8f03-c6713d044c87/​EN_product-info_Axiocam-506_mono.pdf|Axiocam 506m]] camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. It is also equipped with a high sensitivity [[https://​www.photometrics.com/​products/​prime-family/​primebsiexpress|Photometrics Prime BSI Express]] sCMOS camera for high resolution imaging with maximized signal detection. {{  :​widefield_lightpath.png?​0x300}}The Zeiss Cell Observer is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging with fast acquisition speeds. It is equipped with a large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. The stage is furthermore equipped with a piezo for fast Z displacement. You can choose between a HXP metal halide lamp or fast-switching LEDs for illumination. Its cooled [[https://​asset-downloads.zeiss.com/​catalogs/​download/​mic/​a8e5b4d7-25f6-4069-8f03-c6713d044c87/​EN_product-info_Axiocam-506_mono.pdf|Axiocam 506m]] camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. It is also equipped with a high sensitivity [[https://​www.photometrics.com/​products/​prime-family/​primebsiexpress|Photometrics Prime BSI Express]] sCMOS camera for high resolution imaging with maximized signal detection.
  
-  * **Microscope**:​ Zeiss Axio Observer+  * **Microscope**: ​[[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research.html|Zeiss Axio Observer]]
   * **LED Illumination**:​ [[https://​www.zeiss.com/​microscopy/​en/​products/​accessories/​colibri.html|Zeiss Colibri 7]]   * **LED Illumination**:​ [[https://​www.zeiss.com/​microscopy/​en/​products/​accessories/​colibri.html|Zeiss Colibri 7]]
   * **Camera** (left port): [[https://​asset-downloads.zeiss.com/​catalogs/​download/​mic/​a8e5b4d7-25f6-4069-8f03-c6713d044c87/​EN_product-info_Axiocam-506_mono.pdf|Axiocam 506 mono CCD]]   * **Camera** (left port): [[https://​asset-downloads.zeiss.com/​catalogs/​download/​mic/​a8e5b4d7-25f6-4069-8f03-c6713d044c87/​EN_product-info_Axiocam-506_mono.pdf|Axiocam 506 mono CCD]]
   * **Camera** (right port): [[https://​www.photometrics.com/​products/​prime-family/​primebsiexpress|Photometrics Prime BSI Express sCMOS]]   * **Camera** (right port): [[https://​www.photometrics.com/​products/​prime-family/​primebsiexpress|Photometrics Prime BSI Express sCMOS]]
  
-{{:​warning.png?​25|}} Data files older than **15 days** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.+{{::​phenocycler.png?​260 ​ |}}This system is also set up to work together with the [[https://​www.youtube.com/​watch?​v=OQGJX45Wsgw|AKOYA PhenoCycler]] fluidics instrument for automated iterative imaging cycles of whole slide tissues for [[https://​www.akoyabio.com/​why-spatial-biology/​|Spatial Biology]] applications,​ such as image-based quantification of biomarkers to predict immunotherapy response, or quantification of cells by lineage and variant with single-cell resolution in the context of an intact tissue sample. 
 + 
 +  * [[https://​www.youtube.com/​watch?​v=OQGJX45Wsgw|Understanding the PhenoCycler Technology]]  
 +  * [[https://​www.akoyabio.com/​webinar/​a-beginners-guide-to-codex/​|A Beginner’s Guide to CODEX]] 
 +  * [[https://​www.akoyabio.com/​webinar/​spatial-phenotyping-a-revolutionary-approach-to-biomarker-discovery-for-cancer-immunotherapy/​|Spatial Phenotyping:​ A Revolutionary Approach to Biomarker Discovery for Cancer Immunotherapy]] 
 + 
 +{{:​warning.png?​25|}} Data files older than **15 days** will be automatically deleted on this system, please copy your data to the GIMM server using the desktop link.
  
 ===== Booking Rules ===== ===== Booking Rules =====
Line 94: Line 99:
   * Turn on the temperature and CO2 controller - white power strip (if you need them).   * Turn on the temperature and CO2 controller - white power strip (if you need them).
   * If you need CO2, open the Cell Observer CO2 valve   * If you need CO2, open the Cell Observer CO2 valve
-  * Turn on the motorized stage controller (**A** on remote control)+  * Turn on the motorized stage controller (**1** on remote control)
 {{zeiss_axio_observer_a.jpg?​height=150|}} {{zeiss_axio_observer_a.jpg?​height=150|}}
-  * Turn on the microscope power supply (**B** on remote control)+  * Turn on the microscope power supply (**2** on remote control)
 {{zeiss_axio_observer_b.jpg?​height=150|}} {{zeiss_axio_observer_b.jpg?​height=150|}}
   * Turn on the computer   * Turn on the computer
Line 104: Line 109:
 {{::​workspace_selection.png?​250|}} {{::​workspace_selection.png?​250|}}
  
-===== Microscope ​Turn Off procedures =====+===== System ​Turn Off procedures =====
 If there is another user for this microscope is the __next hour__: If there is another user for this microscope is the __next hour__:
   * Leave the fluorescent light source on   * Leave the fluorescent light source on
Line 111: Line 116:
   * Exit the ZEN software   * Exit the ZEN software
   * Turn off the computer (not the UPS!)   * Turn off the computer (not the UPS!)
-{{:​cell_observer_pc_vs_ups.png?​250|}} 
   * Clean up immersion objectives   * Clean up immersion objectives
-  * Turn off the microscope power supply (**B** on remote control) +  * Turn off the microscope power supply (**2** on remote control) 
-  * Turn off the motorized stage controller (**A** on remote control)+  * Turn off the motorized stage controller (**1** on remote control)
   * Turn off the Temperature and CO2 controller - white power strip (if used)   * Turn off the Temperature and CO2 controller - white power strip (if used)
   * Close the Cell Observer CO2 valve (if used)   * Close the Cell Observer CO2 valve (if used)
zeiss_cell_observer.1706441481.txt.gz · Last modified: 2024/01/28 12:31 by bioimaging