zeiss_cell_observer [2024/01/28 12:13] bioimaging |
zeiss_cell_observer [2025/01/14 16:34] (current) bioimaging [Microscope overview] |
||
---|---|---|---|
Line 1: | Line 1: | ||
<html> | <html> | ||
- | <img src="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_cell_observer_name_new.png"> | + | <img src="/facility/bioimaging/lib/exe/fetch.php?media=lisbon_zeiss_cell_observer_name_gimm_2024.png"> |
<table style="border:0px solid white;"> | <table style="border:0px solid white;"> | ||
<tr style="border:0px solid white;"> | <tr style="border:0px solid white;"> | ||
<td style="border:0px solid white;"> | <td style="border:0px solid white;"> | ||
- | <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_cell_observer_wiki_2022.png"><img src="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_cell_observer_wiki_2022.png" width=300></a> | + | <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_cell_observer_wiki_2024.png"><img src="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_cell_observer_wiki_2024.png" width=300></a> |
<td style="border:0px solid white;"> <p style="line-height:1.8"> | <td style="border:0px solid white;"> <p style="line-height:1.8"> | ||
- | <b>Location</b>: <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_cell_observer_map_new_p2a24.png">Room P2-A-24</a> (<img src="/facility/bioimaging/lib/exe/fetch.php?media=phone_neg.png" width=15> 47219) <br> | + | <b>Location</b>: <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_cell_observer_map_new_p2a24.png">[Lisbon] Room P2-A-24</a> (<img src="/facility/bioimaging/lib/exe/fetch.php?media=phone_neg.png" width=15> 47219) <br> |
<b>Manufacturer</b>: <a href="http://www.zeiss.de/micro" target="_blank">ZEISS Microscopy</a><br> | <b>Manufacturer</b>: <a href="http://www.zeiss.de/micro" target="_blank">ZEISS Microscopy</a><br> | ||
<b>Model</b>: Axio Observer<br> | <b>Model</b>: Axio Observer<br> | ||
Line 15: | Line 15: | ||
  <br> |   <br> | ||
Data will be deleted after: <b>15 days</b> | Data will be deleted after: <b>15 days</b> | ||
- |   <br> | ||
  <br> |   <br> | ||
  <br> |   <br> | ||
Line 28: | Line 27: | ||
===== Microscope overview ===== | ===== Microscope overview ===== | ||
- | {{ :widefield_lightpath.png?0x300}}The Zeiss Cell Observer is a fully motorized inverted //widefield fluorescence microscope// ideal for live-cell imaging with fast acquisition speeds. It is equipped with a large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. The stage is furthermore equipped with a piezo for fast Z displacement. You can choose between a HXP metal halide lamp or fast-switching LEDs for illumination. Its sensitive cooled Axiocam 506m camera allows you to capture weak fluorescent signals and minimize photobleaching/photodamage in light sensitive samples. | + | {{ :widefield_lightpath.png?0x300}}The Zeiss Cell Observer is a fully motorized inverted //widefield fluorescence microscope// ideal for live-cell imaging with fast acquisition speeds. It is equipped with a large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. The stage is furthermore equipped with a piezo for fast Z displacement. You can choose between a HXP metal halide lamp or fast-switching LEDs for illumination. Its cooled [[https://asset-downloads.zeiss.com/catalogs/download/mic/a8e5b4d7-25f6-4069-8f03-c6713d044c87/EN_product-info_Axiocam-506_mono.pdf|Axiocam 506m]] camera allows you to capture weak fluorescent signals and minimize photobleaching/photodamage in light sensitive samples. It is also equipped with a high sensitivity [[https://www.photometrics.com/products/prime-family/primebsiexpress|Photometrics Prime BSI Express]] sCMOS camera for high resolution imaging with maximized signal detection. |
+ | |||
+ | * **Microscope**: [[https://www.zeiss.com/microscopy/en/products/light-microscopes/widefield-microscopes/axio-observer-for-life-science-research.html|Zeiss Axio Observer]] | ||
+ | * **LED Illumination**: [[https://www.zeiss.com/microscopy/en/products/accessories/colibri.html|Zeiss Colibri 7]] | ||
+ | * **Camera** (left port): [[https://asset-downloads.zeiss.com/catalogs/download/mic/a8e5b4d7-25f6-4069-8f03-c6713d044c87/EN_product-info_Axiocam-506_mono.pdf|Axiocam 506 mono CCD]] | ||
+ | * **Camera** (right port): [[https://www.photometrics.com/products/prime-family/primebsiexpress|Photometrics Prime BSI Express sCMOS]] | ||
+ | |||
+ | {{::phenocycler.png?260 |}}This system is also set up to work together with the [[https://www.youtube.com/watch?v=OQGJX45Wsgw|AKOYA PhenoCycler]] fluidics instrument for automated iterative imaging cycles of whole slide tissues for [[https://www.akoyabio.com/why-spatial-biology/|Spatial Biology]] applications, such as image-based quantification of biomarkers to predict immunotherapy response, or quantification of cells by lineage and variant with single-cell resolution in the context of an intact tissue sample. | ||
- | * **Microscope**: [[http://www.zeiss.com/microscopy/en_de/products/light-microscopes/axio-observer-for-biology.html|Zeiss Axio Observer]] | + | * [[https://www.youtube.com/watch?v=OQGJX45Wsgw|Understanding the PhenoCycler Technology]] |
- | * **LED Illumination**: [[https://www.zeiss.com/microscopy/int/products/microscope-components/lightsources/colibri-7.html?vaURL=www.zeiss.de/colibri|Zeiss Colibri 7]] | + | * [[https://www.akoyabio.com/webinar/a-beginners-guide-to-codex/|A Beginner’s Guide to CODEX]] |
- | * **Camera**: [[https://www.zeiss.com/microscopy/int/products/microscope-cameras/axiocam-506-mono.html|Axiocam 506 mono CCD]] | + | * [[https://www.akoyabio.com/webinar/spatial-phenotyping-a-revolutionary-approach-to-biomarker-discovery-for-cancer-immunotherapy/|Spatial Phenotyping: A Revolutionary Approach to Biomarker Discovery for Cancer Immunotherapy]] |
- | {{:warning.png?25|}} Data files older than **15 days** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. | + | {{:warning.png?25|}} Data files older than **15 days** will be automatically deleted on this system, please copy your data to the GIMM server using the desktop link. |
===== Booking Rules ===== | ===== Booking Rules ===== | ||
Line 93: | Line 99: | ||
* Turn on the temperature and CO2 controller - white power strip (if you need them). | * Turn on the temperature and CO2 controller - white power strip (if you need them). | ||
* If you need CO2, open the Cell Observer CO2 valve | * If you need CO2, open the Cell Observer CO2 valve | ||
- | * Turn on the motorized stage controller (**A** on remote control) | + | * Turn on the motorized stage controller (**1** on remote control) |
{{zeiss_axio_observer_a.jpg?height=150|}} | {{zeiss_axio_observer_a.jpg?height=150|}} | ||
- | * Turn on the microscope power supply (**B** on remote control) | + | * Turn on the microscope power supply (**2** on remote control) |
{{zeiss_axio_observer_b.jpg?height=150|}} | {{zeiss_axio_observer_b.jpg?height=150|}} | ||
* Turn on the computer | * Turn on the computer | ||
Line 103: | Line 109: | ||
{{::workspace_selection.png?250|}} | {{::workspace_selection.png?250|}} | ||
- | ===== Microscope Turn Off procedures ===== | + | ===== System Turn Off procedures ===== |
If there is another user for this microscope is the __next hour__: | If there is another user for this microscope is the __next hour__: | ||
* Leave the fluorescent light source on | * Leave the fluorescent light source on | ||
Line 110: | Line 116: | ||
* Exit the ZEN software | * Exit the ZEN software | ||
* Turn off the computer (not the UPS!) | * Turn off the computer (not the UPS!) | ||
- | {{:cell_observer_pc_vs_ups.png?250|}} | ||
* Clean up immersion objectives | * Clean up immersion objectives | ||
- | * Turn off the microscope power supply (**B** on remote control) | + | * Turn off the microscope power supply (**2** on remote control) |
- | * Turn off the motorized stage controller (**A** on remote control) | + | * Turn off the motorized stage controller (**1** on remote control) |
* Turn off the Temperature and CO2 controller - white power strip (if used) | * Turn off the Temperature and CO2 controller - white power strip (if used) | ||
* Close the Cell Observer CO2 valve (if used) | * Close the Cell Observer CO2 valve (if used) |