User Tools

Site Tools


zeiss_axiovert_200m

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
zeiss_axiovert_200m [2025/07/19 21:31]
bioimaging [Microscope Turn Off procedures]
zeiss_axiovert_200m [2025/12/12 11:57] (current)
bioimaging
Line 28: Line 28:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-{{  :​widefield_lightpath.png?​0x300}}The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera ([[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics CoolSNAP HQ CCD]]) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. It is also equipped with a color camera ([[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]]) for acquisition of histological stains with tile and stitching imaging.+The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera ([[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics CoolSNAP HQ CCD]]) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. It is also equipped with a color camera ([[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]]) for acquisition of histological stains with tile and stitching imaging.
  
   * **Microscope**:​ Zeiss Axiovert 200   * **Microscope**:​ Zeiss Axiovert 200
Line 40: Line 40:
 ==== Filtersets ==== ==== Filtersets ====
  
-^  Position ​ ^  Filterset ​ ​^ ​ Reference ​ ​^ ​ Excitation ​ ^  Dichroic ​ ^  Emission ​ ^ +^  Position ​ ^  Filterset ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ​^ ​ Reference ​ ^ 
-|  1  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488001-9901-000&​o=|FS01]] ​ |  ​359-371 nm  ​|  ​395 nm  ​|  ​> 397 nm  ​+|  1  |  Blue  ​| ​ 359-371 nm  |  395 nm  |  <fc #​be00cc>>​ 397 nm</​fc> ​ ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488001-9901-000&​o=|FS01]]  ​
-|  ​ ​|  ​Green BP  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488010-9901-000&​o=|FS10]] ​ |  ​450-490 nm  ​|  ​510 nm  ​|  ​515-565 nm  ​+|  ​ ​|  ​Green BP  ​|  ​450-490 ​nm  |  ​510 nm  ​|  ​<fc #​81ff00>​515-565 nm</​fc> ​ ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488010-9901-000&​o=|FS10]]  ​
-|  ​ ​|  ​Red  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488020-9901-000&​o=|FS20]] ​ |  ​540-552 nm  ​|  ​560 nm  ​|  ​575-640 nm  ​+|  ​ ​|  ​Red  ​|  ​540-552 nm  |  ​560 nm  ​|  ​<fc #​ffa600>​575-640 nm</​fc> ​ ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488020-9901-000&​o=|FS20]]  ​
-|  ​ ​|  ​Far Red  ​| ​ [[http://​www.semrock.com/​SetDetails.aspx?​id=2983|Cy5-4040C-000]] ​ ​| ​ 608-648 nm  |  660 nm  |  672-712 nm  | +|  ​ ​|  ​Far Red  ​|  ​608-648 nm  |  ​660 nm  ​|  ​<fc #​ff0000>​672-712 nm</​fc> ​ ​| ​ [[http://​www.semrock.com/​SetDetails.aspx?​id=2983|Cy5-4040C-000]] ​ | 
-|  5  |  ​ ​| ​ ​none  ​||||+|  5  |  ​none  |||||
  
 **Upon request:** **Upon request:**
  
 ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^ ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^
-|  2  |  Green LP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488009-9901-000&​o=|FS09]] ​ ​| ​ 450-490 nm  |  510 nm  |  > 515 nm  |+|  2  |  Green LP  ​| ​ 450-490 nm  |  510 nm  |  <fc #​1fff00>>​ 515 nm</​fc> ​ ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488009-9901-000&​o=|FS09]] ​ |
  
 ==== Objectives ==== ==== Objectives ====
 ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color) ​ 10 μm =  ^  Reference ​ ^ ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color) ​ 10 μm =  ^  Reference ​ ^
-|  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9900-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9900-000]] ​ | +|  ​<fc #fef042>10x</​fc> ​ ​| ​ EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9900-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9900-000]] ​ | 
-|  20x  |  EC Plan-Neofluar ​ |  Air  |  0.50  |  2.00  |  0.48  |  21 pixels ​ |  46.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440340-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5|440340-9904-000]] ​ | +|  ​<fc #0aa05c>20x</​fc> ​ ​| ​ EC Plan-Neofluar ​ |  Air  |  0.50  |  2.00  |  0.48  |  21 pixels ​ |  46.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440340-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5|440340-9904-000]] ​ | 
-|  40x  |  EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440350-9903-000/​Objective-EC-Plan-Neofluar-40x-0.75|440350-9903-000]] ​ | +|  ​<fc #01b3f5>40x</​fc> ​ ​| ​ EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440350-9903-000/​Objective-EC-Plan-Neofluar-40x-0.75|440350-9903-000]] ​ | 
-|  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |+|  ​<fc #2c80c0>63x</​fc> ​ ​| ​ Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |
 |  100x  |  α Plan-Apochromat DIC  |  Oil  |  1.46  |  0.11  |  0.09  |  105 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420792-9800-000/​Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27|420792-9800-000]] ​ | |  100x  |  α Plan-Apochromat DIC  |  Oil  |  1.46  |  0.11  |  0.09  |  105 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420792-9800-000/​Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27|420792-9800-000]] ​ |
  
Line 63: Line 63:
 **Upon request:** **Upon request:**
 ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^  Reference ​ ^ ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^  Reference ​ ^
-|  1.25x  |  EC Epiplan-Neofluar ​ |  Air  |  0.035  |  4  |  7.58  |  1.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​422310-9900-000/​Objective-EC-Epiplan-Neofluar-1.25x-0.03-M27|422310-9900-000]] ​ | +|  ​<fc #88888a>1.25x</​fc> ​ ​| ​ EC Epiplan-Neofluar ​ |  Air  |  0.035  |  4  |  7.58  |  1.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​422310-9900-000/​Objective-EC-Epiplan-Neofluar-1.25x-0.03-M27|422310-9900-000]] ​ | 
-|  5x  |  EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.5  |  2.00  |  5 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ | +|  ​<fc #df2b37>5x</​fc> ​ ​| ​ EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.5  |  2.00  |  5 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ | 
-|  40x  |  Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  0.24  |  41 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ | +|  ​<fc #01b3f5>40x</​fc> ​ ​| ​ Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  0.24  |  41 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ | 
-|  63x  |  Plan-Apochromat Ph3  |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420781-9910-000/​Objective-Plan-Apochromat-63-1.4-Oil-Ph3-M27|420781-9910-000]] ​ |+|  ​<fc #2c80c0>63x</​fc> ​ ​| ​ Plan-Apochromat Ph3  |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420781-9910-000/​Objective-Plan-Apochromat-63-1.4-Oil-Ph3-M27|420781-9910-000]] ​ |
  
 *** pixel sizes for binning = 1** *** pixel sizes for binning = 1**
Line 80: Line 80:
 Y = -8995 μm Y = -8995 μm
  
-===== System ​Turn On Procedures ​=====+===== Turn ON Procedure ​=====
   * Turn on the fluorescent light power source (if used)   * Turn on the fluorescent light power source (if used)
 {{halide_710.jpg?​80|}} {{halide_710.jpg?​80|}}
Line 93: Line 93:
   * Start the Metamorph software   * Start the Metamorph software
   * If the software doesn'​t detect the camera, power cycle the camera and try again   * If the software doesn'​t detect the camera, power cycle the camera and try again
-===== Microscope ​Turn Off procedures ​=====+  *  
 +===== Turn OFF procedure ​=====
  
 If there is another user for this microscope in the __next hour__: If there is another user for this microscope in the __next hour__:
zeiss_axiovert_200m.1752953491.txt.gz · Last modified: 2025/07/19 21:31 by bioimaging