Previous revision
oeiras_zeiss_lightsheet_z1 [2025/01/06 00:53]
bioimaging
oeiras_zeiss_lightsheet_z1 [2026/02/17 17:46] (current)
bioimaging [Filtersets]
Line 4: Line 4:
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lightsheet_z1_wiki_2024.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=oeiras_zeiss_lightsheet_z1_wiki_2024.png" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lightsheet.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lightsheet.jpg" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ [Oeiras] Room 0B03<​br> ​+<​b>​Location</​b>: ​<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=bartolomeu_dias_wing_2025_-_z1.png">​[Oeiras] Room 0B03</a><​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​
 <​b>​Model</​b>:​ <a href="​https://​www.youtube.com/​watch?​v=vKHQudCKVGc"​ target="​_blank">​Lightsheet Z.1</​a>​ (click for Zeiss webinar)<​br>​ <​b>​Model</​b>:​ <a href="​https://​www.youtube.com/​watch?​v=vKHQudCKVGc"​ target="​_blank">​Lightsheet Z.1</​a>​ (click for Zeiss webinar)<​br>​
 <​b>​Nickname</​b>:​ "​Lightsheet"<​br>​ <​b>​Nickname</​b>:​ "​Lightsheet"<​br>​
-<​b>​Software</​b>:​ ZEN 2014 SP1 v9.0.0.0 <br>+<​b>​Software</​b>:​ ZEN 3.1 LS (HF 16)<br>
 <​b>​Year</​b>:​ 2020 <br> <​b>​Year</​b>:​ 2020 <br>
 <​b>​SN</​b>:​ 2583000325 <br> <​b>​SN</​b>:​ 2583000325 <br>
Line 18: Line 18:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lightsheet_z1_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​Zeiss Lightsheet Z.1 Usage Statistics</​a>​+&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=oeiras_lightsheet_z1_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ZEISS Lightsheet Z.1 Usage Statistics</​a>​
  </​p>​  </​p>​
 </td> </td>
Line 57: Line 57:
  
 ==== LASERs ==== ==== LASERs ====
-^  ​Laser Unit  ​^ ​ Wavelength ​ ^  Maximum Power  ^ + 
-|  ​Solid State 445|  445 nm  |  20 mW  | +^  ​LASER  ​^ ​ Wavelength ​ ^  Maximum Power  ^ 
-|  ​Solid State 488  ​| ​ 488 nm  |  50 mW  | +|  ​Blue-Violet  ​|  ​<fc #0028ff>445 nm</​fc> ​ ​| ​ 20 mW  | 
-|  ​Solid State 561 |  561 nm  |  50 mW  | +|  ​Blue  ​|  ​<fc #00f7ff>488 nm</​fc> ​ ​| ​ 50 mW  | 
-|  ​Solid State 638  ​| ​ 638 nm  |  75 mW  |+|  ​Yellow-Green  ​|  ​<fc #c6ff00>561 nm</​fc> ​ ​| ​ 50 mW  | 
 +|  ​Red  ​|  ​<fc #ff2600>638 nm</​fc> ​ ​| ​ 75 mW  |
  
 ==== Objectives (Illumination) ==== ==== Objectives (Illumination) ====
  
 ^  Magnification ​ ^  Model  ^  NA  ^ ^  Magnification ​ ^  Model  ^  NA  ^
-|  10x  |  Lightsheet Z.1 10x  |  0.20  |+|  ​<fc #fef042>10x</​fc> ​ ​| ​ Lightsheet Z.1 10x  |  0.20  |
  
 ==== Objectives (Detection) ==== ==== Objectives (Detection) ====
  
 ^  Magnification ​  ​^ ​ Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ ^  Magnification ​  ​^ ​ Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
-|  20x  |  W Plan-Apochromat DIC 75mm  |  Water  |  1.00  |  2.4  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421452-9700-000/​Objective-W-Plan-Apochromat-20x-1.0-DIC-M27-75mm#​|421452-9700-000]] ​ | +|  ​<fc #0aa05c>20x</​fc> ​ ​| ​ W Plan-Apochromat DIC 75mm  |  Water  |  1.00  |  2.4  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421452-9700-000/​Objective-W-Plan-Apochromat-20x-1.0-DIC-M27-75mm#​|421452-9700-000]] ​ | 
-|  40x  |  W Plan-Apochromat DIC M27  |  Water  |  1.00  |  2.5  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​421462-9900-799/​Objective-W-Plan-Apochromat-40x-1.0-DIC-M27| 421462-9900-799]] ​ |+|  ​<fc #01b3f5>40x</​fc> ​ ​| ​ W Plan-Apochromat DIC M27  |  Water  |  1.00  |  2.5  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​objectives/​421462-9900-799/​Objective-W-Plan-Apochromat-40x-1.0-DIC-M27| 421462-9900-799]] ​ |
  
 ==== Filtersets ==== ==== Filtersets ====
  
-In each experiment you can only use Filter Turret A (installed by default) or B. Please let the facility staff know that you want to use filter turret B so that they can install and configure it in advance.+In each experiment you can only use Filter Turret A (installed by default) or B. Please let us know that you want to use filter turret B so that we can install and configure it in advance. 
 + 
 +=== Filter Turret A (default) ===
  
-The list of fluorophores presented in both tables is meant to be representative. Use [[https://www.thermofisher.com/order/fluorescence-spectraviewer/|Spectra Viewer]] or [[https://www.fpbase.org|FPBase]] to determine which set of lasers and emission filters you want to optimize the system to the specific fluorophores you have in your sample.+^  Select Label  ^  Camera #1 Filter ​ ^  Camera #2 Filter ​ ^  Fluorophores (Cam #1 Cam #2)  ^ 
 +|  LP 510  |  <fc #​00d5ff>​460-500 nm</fc> ​ |  <fc #​ffef00>>​ 585 nm</fc> ​ |  CFP, mCherry : RFP  | 
 +|  LP 560  |  <fc #​4aff00>​505-545 nm</fc> ​ |  <fc #​ffef00>​565-615 nm</fc> ​ |  GFP, mCherry : RFP  | 
 +|  LP 560 (2)  |  <fc #​4aff00>​505-545 nm</fc>  ​ <​fc #​ffef00>>​ 585 nm</​fc> ​ |  GFP, mCherry ​RFP  | 
 +|  LP 560 (3)  |  <fc #​4aff00>​505-545 nm</fc> ​ |  <fc #​ff0000>>​ 660 nm</fc> ​ |  GFP, mPlum : mStrawberry,​ tdTomato  ​|
  
-^ Select Label ^ Camera #1 Filter ^ Camera #2 Filter ^ Fluorophores (Cam #1 : Cam #2)        ^ Filter Turret ​+=== Filter Turret ​B ===
-| LP 510       | BP 460-500 ​      | LP 585           | CFP, mCherry : RFP                    | A             | +
-| LP 560       | BP 505-545 ​      | BP 565-615 ​      | GFP, mCherry : RFP                    | A             | +
-| LP 560 (2)   | BP 505-545 ​      | LP 585           | GFP, mCherry : RFP                    | A             | +
-| LP 560 (3)   | BP 505-545 ​      | LP 660           | GFP, mPlum : mStrawberry,​ tdTomato ​  | A             |+
  
-^ Select Label ^ Camera #1 Filter ^ Camera #2 Filter ^ Fluorophores (Cam #1 : Cam #2)        ^ Filter Turret ​+ Select Label   Camera #1 Filter ​  Camera #2 Filter ​  Fluorophores (Cam #1 : Cam #2)  
-| LP 510       ​BP 460-500 ​      ​LP 660           ​| CFP, YFP : Cy5                       | B             + LP 510   <​fc #00d5ff>460-500 ​nm</​fc>  ​ <​fc #​ff0000>> ​660 nm</​fc>  ​ CFP, YFP : Cy5  
-| LP 580       ​BP 525-565 ​      ​LP 585           ​| YFP, mCherry : mPlum                  | B             |+ LP 580   <​fc #92ff00>525-565 ​nm</​fc>  ​ <​fc #​ffef00>> ​585 nm</​fc>  ​ YFP, mCherry : mPlum  |
  
  
Line 97: Line 100:
   * If the computer is already turned on, restart it. Start the system and incubator if you are using either CO2, humidity or/and Peltier modules. Check the humidifier bottle, and replace water if necessary.   * If the computer is already turned on, restart it. Start the system and incubator if you are using either CO2, humidity or/and Peltier modules. Check the humidifier bottle, and replace water if necessary.
  
-  * Start the Zen Black software (icon in Windows desktop), select the “start system” with the “boot status” option on, and confirm that no errors show up.+  * Start the **ZEN** ​software (icon in Windows desktop), select the “start system” with the “boot status” option on, and confirm that no errors show up.
  
 If you do not start the incubator system, you may receive errors relating to the absence of these systems in ZEN software; however the system should be working as expected. If this is not the case, please contact the facility staff. If you do not start the incubator system, you may receive errors relating to the absence of these systems in ZEN software; however the system should be working as expected. If this is not the case, please contact the facility staff.
oeiras_zeiss_lightsheet_z1.1736121206.txt.gz · Last modified: 2025/01/06 00:53 by bioimaging