User Tools

Site Tools


oeiras_zeiss_lightsheet_z1

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
oeiras_zeiss_lightsheet_z1 [2026/11/16 17:20] – external edit 127.0.0.1oeiras_zeiss_lightsheet_z1 [2026/11/17 10:19] (current) – bioimaging
Line 28: Line 28:
  
 {{  :lightsheet_z.jpg?0x380|}} The Zeiss Lightsheet Z.1 is a //light sheet fluorescence microscope// able to image optical sections of large samples at subcellular resolution and very fast rates, with almost no phototoxicity or bleaching. [[https://www.zeiss.com/content/dam/Microscopy/Products/imaging-systems/lattice-lightsheet/lattice-lightsheet-7/zeiss-lattice-lightsheet-7-beam-splitting.svg|It splits fluorescence excitation and detection into two separate light paths]], with the axis of illumination being perpendicular to the detection axis.  {{  :lightsheet_z.jpg?0x380|}} The Zeiss Lightsheet Z.1 is a //light sheet fluorescence microscope// able to image optical sections of large samples at subcellular resolution and very fast rates, with almost no phototoxicity or bleaching. [[https://www.zeiss.com/content/dam/Microscopy/Products/imaging-systems/lattice-lightsheet/lattice-lightsheet-7/zeiss-lattice-lightsheet-7-beam-splitting.svg|It splits fluorescence excitation and detection into two separate light paths]], with the axis of illumination being perpendicular to the detection axis. 
-{{:lightsheet_illumination.jpg|Since only a single thin section of the sample is illuminated by the light sheet}}, optical sectioning is achieved without a pinhole or image processing deconvolution. Light from the in-focus plane is collected by a sCMOS camera rather than pixel by pixel as in a point scanning laser confocal. This allows you to collect images faster and with less excitation light than you would with many other optical-sectioning microscopy techniques. This system features two objectives with fields of view around 1 mm or 500 µm and resolutions between 0.15 µm and 0.3 µm, equipped with lasers spanning blue to far-red wavelengths (445 nm, 488 nm, 561 nm, and 638 nm) and appropriate fluorescence emission filters. Designed for live imaging, samples are embedded in agarose and preferably loaded into glass or plastic capillaries that provide heating and cooling to maintain physiological conditions, making the system ideal for observing live cells, embryos, Drosophila, and zebrafish. It is important to note that this Z.1 is optimized for live samples and does not include a kit for cleared samples; for such applications, other microscopes are recommended. Users should consult with facility staff to determine the best technique for their specific research needs. +[[https://imm.medicina.ulisboa.pt/facility/bioimaging/lib/exe/fetch.php?media=lightsheet_illumination.jpg|Since only a single thin section of the sample is illuminated by the light sheet]], optical sectioning is achieved without a pinhole or image processing deconvolution. Light from the in-focus plane is collected by a sCMOS camera rather than pixel by pixel as in a point scanning laser confocal. This allows you to collect images faster and with less excitation light than you would with many other optical-sectioning microscopy techniques. This system features two objectives with fields of view around 1 mm or 500 µm and resolutions between 0.15 µm and 0.3 µm, equipped with lasers spanning blue to far-red wavelengths (445 nm, 488 nm, 561 nm, and 638 nm) and appropriate fluorescence emission filters. Designed for live imaging, samples are embedded in agarose and preferably loaded into glass or plastic capillaries that provide heating and cooling to maintain physiological conditions, making the system ideal for observing live cells, embryos, Drosophila, and zebrafish. It is important to note that this Z.1 is optimized for live samples and does not include a kit for cleared samples; for such applications, other microscopes are recommended. Users should consult with facility staff to determine the best technique for their specific research needs. 
  
 {{:info.png?25|}} Click on the image on the right to see the system beam path in higher detail {{:info.png?25|}} Click on the image on the right to see the system beam path in higher detail
Line 58: Line 58:
 ==== LASERs ==== ==== LASERs ====
  
-^  LASER  ^  Wavelength  ^  Maximum Power  ^ +<html> 
-|  Blue-Violet  |  <fc #0028ff>445 nm</fc>  |  20 mW  | + 
-|  Blue  |  <fc #00f7ff>488 nm</fc>  |  50 mW  | +<style> 
-|  Yellow-Green  |  <fc #c6ff00>561 nm</fc>  |  50 mW  | +  table.centered th, 
-|  Red  |  <fc #ff2600>638 nm</fc>  |  75 mW  |+  table.centered td { text-align: center; vertical-align: middle; } 
 +</style> 
 + 
 +<table class="centered"> 
 +  <thead> 
 +    <tr> 
 +      <th>LASER</th> 
 +      <th>Wavelength</th> 
 +      <th>Maximum Power</th> 
 +    </tr> 
 +  </thead> 
 +  <tbody> 
 +    <tr> 
 +      <td>Blue-Violet</td> 
 +      <td><span style="color:#0028ff">445 nm</span></td> 
 +      <td>20 mW</td> 
 +    </tr> 
 +    <tr> 
 +      <td>Blue</td> 
 +      <td><span style="color:#00f7ff">488 nm</span></td> 
 +      <td>50 mW</td> 
 +    </tr> 
 +    <tr> 
 +      <td>Yellow-Green</td> 
 +      <td><span style="color:#c6ff00">561 nm</span></td> 
 +      <td>50 mW</td> 
 +    </tr> 
 +    <tr> 
 +      <td>Red</td> 
 +      <td><span style="color:#ff2600">638 nm</span></td> 
 +      <td>75 mW</td> 
 +    </tr> 
 +  </tbody> 
 +</table> 
 +</html>
  
 ==== Objectives (Illumination) ==== ==== Objectives (Illumination) ====
  
-^  Magnification  ^  Model  ^  NA  ^ +<html> 
-|  <fc #fef042>10x</fc>  |  Lightsheet Z.1 10x  |  0.20  |+<table class="centered"> 
 +  <thead> 
 +    <tr> 
 +      <th>Magnification</th> 
 +      <th>Model</th> 
 +      <th>NA</th> 
 +    </tr> 
 +  </thead> 
 +  <tbody> 
 +    <tr> 
 +      <td><span style="color:#fef042">10x</span></td> 
 +      <td>Lightsheet Z.1 10x</td> 
 +      <td>0.20</td> 
 +    </tr> 
 +  </tbody> 
 +</table> 
 +</html>
  
 ==== Objectives (Detection) ==== ==== Objectives (Detection) ====
  
-^  Magnification   ^  Model  ^  Immersion  ^  NA  ^  WD (mm)  ^  Reference  ^ +<html> 
-|  <fc #0aa05c>20x</fc>  |  W Plan-Apochromat DIC 75mm  |  Water  |  1.00  |  2.4  |  [[https://www.micro-shop.zeiss.com/en/de/shop/objectives/421452-9700-000/Objective-W-Plan-Apochromat-20x-1.0-DIC-M27-75mm#|421452-9700-000]]  | +<table class="centered"> 
-|  <fc #01b3f5>40x</fc>  |  W Plan-Apochromat DIC M27  |  Water  |  1.00  |  2.5  |  [[https://www.micro-shop.zeiss.com/en/us/shop/objectives/421462-9900-799/Objective-W-Plan-Apochromat-40x-1.0-DIC-M27| 421462-9900-799]]  |+  <thead> 
 +    <tr> 
 +      <th>Magnification</th> 
 +      <th>Model</th> 
 +      <th>Immersion</th> 
 +      <th>NA</th> 
 +      <th>WD (mm)</th> 
 +      <th>Reference</th> 
 +    </tr> 
 +  </thead> 
 +  <tbody> 
 +    <tr> 
 +      <td><span style="color:#0aa05c">20x</span></td> 
 +      <td>W Plan-Apochromat DIC 75mm</td> 
 +      <td>Water</td> 
 +      <td>1.00</td> 
 +      <td>2.4</td> 
 +      <td><a href="https://www.micro-shop.zeiss.com/en/de/shop/objectives/421452-9700-000/Objective-W-Plan-Apochromat-20x-1.0-DIC-M27-75mm#">421452-9700-000</a></td> 
 +    </tr> 
 +    <tr> 
 +      <td><span style="color:#01b3f5">40x</span></td> 
 +      <td>W Plan-Apochromat DIC M27</td> 
 +      <td>Water</td> 
 +      <td>1.00</td> 
 +      <td>2.5</td> 
 +      <td><a href="https://www.micro-shop.zeiss.com/en/us/shop/objectives/421462-9900-799/Objective-W-Plan-Apochromat-40x-1.0-DIC-M27">421462-9900-799</a></td> 
 +    </tr> 
 +  </tbody> 
 +</table> 
 +</html>
  
 ==== Filtersets ==== ==== Filtersets ====
Line 81: Line 160:
 === Filter Turret A (default) === === Filter Turret A (default) ===
  
-^  Select Label  ^  Camera #1 Filter  ^  Camera #2 Filter  ^  Fluorophores (Cam #1 : Cam #2)  ^ +<html> 
-|  LP 510  |  <fc #00d5ff>460-500 nm</fc>  |  <fc #ffef00>> 585 nm</fc>  |  CFP, mCherry : RFP  | +<table class="centered"> 
-|  LP 560  |  <fc #4aff00>505-545 nm</fc>  |  <fc #ffef00>565-615 nm</fc>  |  GFP, mCherry : RFP  | +  <thead> 
-|  LP 560 (2)  |  <fc #4aff00>505-545 nm</fc>  |  <fc #ffef00>> 585 nm</fc>  |  GFP, mCherry : RFP  | +    <tr> 
-|  LP 560 (3)  |  <fc #4aff00>505-545 nm</fc>  |  <fc #ff0000>> 660 nm</fc>  |  GFP, mPlum : mStrawberry, tdTomato  |+      <th>Select Label</th> 
 +      <th>Camera #1 Filter</th> 
 +      <th>Camera #2 Filter</th> 
 +      <th>Fluorophores (Cam #1 : Cam #2)</th> 
 +    </tr> 
 +  </thead> 
 +  <tbody> 
 +    <tr> 
 +      <td>LP 510</td> 
 +      <td><span style="color:#00d5ff">460-500 nm</span></td> 
 +      <td><span style="color:#ffef00">&gt; 585 nm</span></td> 
 +      <td>CFP, mCherry : RFP</td> 
 +    </tr> 
 +    <tr> 
 +      <td>LP 560</td> 
 +      <td><span style="color:#4aff00">505-545 nm</span></td> 
 +      <td><span style="color:#ffef00">565-615 nm</span></td> 
 +      <td>GFP, mCherry : RFP</td> 
 +    </tr> 
 +    <tr> 
 +      <td>LP 560 (2)</td> 
 +      <td><span style="color:#4aff00">505-545 nm</span></td> 
 +      <td><span style="color:#ffef00">&gt; 585 nm</span></td> 
 +      <td>GFP, mCherry : RFP</td> 
 +    </tr> 
 +    <tr> 
 +      <td>LP 560 (3)</td> 
 +      <td><span style="color:#4aff00">505-545 nm</span></td> 
 +      <td><span style="color:#ff0000">&gt; 660 nm</span></td> 
 +      <td>GFP, mPlum : mStrawberry, tdTomato</td> 
 +    </tr> 
 +  </tbody> 
 +</table> 
 +</html>
  
 === Filter Turret B === === Filter Turret B ===
  
-^  Select Label  ^  Camera #1 Filter  ^  Camera #2 Filter  ^  Fluorophores (Cam #1 : Cam #2)  ^ +<html> 
-|  LP 510  |  <fc #00d5ff>460-500 nm</fc>  |  <fc #ff0000>> 660 nm</fc>  |  CFP, YFP : Cy5  | +<table class="centered"> 
-|  LP 580  |  <fc #92ff00>525-565 nm</fc>  |  <fc #ffef00>> 585 nm</fc>  |  YFP, mCherry : mPlum  | +  <thead> 
 +    <tr> 
 +      <th>Select Label</th> 
 +      <th>Camera #1 Filter</th> 
 +      <th>Camera #2 Filter</th> 
 +      <th>Fluorophores (Cam #1 : Cam #2)</th> 
 +    </tr> 
 +  </thead> 
 +  <tbody> 
 +    <tr> 
 +      <td>LP 510</td> 
 +      <td><span style="color:#00d5ff">460-500 nm</span></td> 
 +      <td><span style="color:#ff0000">&gt; 660 nm</span></td> 
 +      <td>CFP, YFP : Cy5</td> 
 +    </tr> 
 +    <tr> 
 +      <td>LP 580</td> 
 +      <td><span style="color:#92ff00">525-565 nm</span></td> 
 +      <td><span style="color:#ffef00">&gt; 585 nm</span></td> 
 +      <td>YFP, mCherry : mPlum</td> 
 +    </tr> 
 +  </tbody> 
 +</table> 
 +</html>
  
 ===== Turn On Procedures ===== ===== Turn On Procedures =====
oeiras_zeiss_lightsheet_z1.txt · Last modified: by bioimaging

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki