User Tools

Site Tools


nikon_eclipse_ti

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
nikon_eclipse_ti [2025/12/12 01:15]
bioimaging
nikon_eclipse_ti [2025/12/12 01:27] (current)
bioimaging [Objectives]
Line 39: Line 39:
 ==== Filtersets ==== ==== Filtersets ====
  
-^  Position ​ ^  Filterset ​ ​^ ​ Reference ​ ​^ ​ Excitation ​ ^  Dichroic ​ ^  Emission ​ ^+^  Position ​ ^  Filterset ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ​^ ​ Reference ​ ^
 |  1  |  Empty  ||||| |  1  |  Empty  |||||
-|  2  |  ​DAPI  |  MBE41300 ​ ​| ​ 340-380 nm  |  400 nm  |  435-485 nm  | +|  2  |  ​Blue  ​| ​ 340-380 nm  |  400 nm  |  ​<fc #007bff>435-485 nm</​fc> ​ |  MBE41300 ​ | 
-|  3  |  ​FITC  |  MBE44720 ​ ​| ​ 465-495 nm  |  505 nm  |  515-555 nm  | +|  3  |  ​Green  ​| ​ 465-495 nm  |  505 nm  |  ​<fc #70ff00>515-555 nm</​fc> ​ |  MBE44720 ​ | 
-|  4  |  ​TRITC  |  MBE45600 ​ ​| ​ 528-553 nm  |  565 nm  |  590-650 nm  | +|  4  |  ​Orange ​ ​| ​ 528-553 nm  |  565 nm  |  ​<fc #ff7700>590-650 nm</​fc> ​ |  MBE45600 ​ | 
-|  5  |  ​Cy5  |  2SK4CY50 ​ ​| ​ 608-648 nm  |  660 nm  |  672-712 nm  |+|  5  |  ​Red  ​| ​ 608-648 nm  |  660 nm  |  ​<fc #ff0000>672-712 nm</​fc> ​ |  2SK4CY50 ​ |
 |  6  |  Empty  ||||| |  6  |  Empty  |||||
  
 ==== Objectives ==== ==== Objectives ====
 ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
-|  10x  |  CFI Plan Fluor DLL Ph1  |  Air  |  0.30  |  16.00  |   ​[[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1835|MRH10101]] ​ | +|  ​<fc #fef042>10x</​fc> ​ ​| ​ CFI Plan Fluor DLL Ph1  |  Air  |  0.30  |  16.00  |   ​[[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1835|MRH10101]] ​ | 
-|  20x  |  CFI S Plan Fluor ELWD ADM Ph1  |  Air  |  0.45  |  6.90 - 8.20  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1813|MRH48230]] ​ | +|  ​<fc #0aa05c>20x</​fc> ​ ​| ​ CFI S Plan Fluor ELWD ADM Ph1  |  Air  |  0.45  |  6.90 - 8.20  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1813|MRH48230]] ​ | 
-|  40x  |  CFI CFI Plan Apochromat Lambda D  |  Air  |  0.95  |  0.21  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-179806|MRH70470]] ​ | +|  ​<fc #01b3f5>40x</​fc> ​ ​| ​ CFI CFI Plan Apochromat Lambda D  |  Air  |  0.95  |  0.21  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-179806|MRH70470]] ​ | 
-|  40x  |  CFI S Plan Fluor ELWD ADM Ph2  |  Air  |  0.60  |  2.80 - 3.60  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1814|MRH48430]] ​ | +|  ​<fc #01b3f5>40x</​fc> ​ ​| ​ CFI S Plan Fluor ELWD ADM Ph2  |  Air  |  0.60  |  2.80 - 3.60  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1814|MRH48430]] ​ | 
-|  60x  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  |+|  ​<fc #2c80c0>60x</​fc> ​  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  |
 |  100x  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  | |  100x  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  |
  
nikon_eclipse_ti.1765498520.txt.gz · Last modified: 2025/12/12 01:15 by bioimaging