User Tools

Site Tools


nikon_eclipse_ti

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
nikon_eclipse_ti [2023/02/22 02:04]
bioimaging [Filtersets Turret 2 (bottom)]
nikon_eclipse_ti [2025/12/12 01:27] (current)
bioimaging [Objectives]
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_name_new.png">​+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lisbon_nikon_eclipse_ti_name_GIMM_2024.png">​
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_wiki_2022.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_wiki_2022.png" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_wiki_2024.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_wiki_2024.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_map_new_p2a24.png">​Room P2-A-24</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) <​br> ​+<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_map_new_p2a24.png">​[Lisbon] ​Room P2-A-24</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​https://​www.microscope.healthcare.nikon.com/​en_EU/"​ target="​_blank">​Nikon Instruments</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​https://​www.microscope.healthcare.nikon.com/​en_EU/"​ target="​_blank">​Nikon Instruments</​a><​br>​
 <​b>​Model</​b>:​ Eclipse Ti<​br>​ <​b>​Model</​b>:​ Eclipse Ti<​br>​
 <​b>​Nickname</​b>:​ "​006"<​br>​ <​b>​Nickname</​b>:​ "​006"<​br>​
-<​b>​Software</​b>:​ NIS-Elements AR 5.11.01<br>+<​b>​Software</​b>:​ NIS-Elements AR 5.42.05<br>
 <​b>​Year</​b>:​ 2010 <br> <​b>​Year</​b>:​ 2010 <br>
 <​b>​SN</​b>:​ 602805 <br> <​b>​SN</​b>:​ 602805 <br>
 &nbsp <br> &nbsp <br>
-&​nbsp ​<br>+Data will be deleted after: ​<b>3 months</​b>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
Line 27: Line 27:
  
 ===== Microscope overview ===== ===== Microscope overview =====
-{{  :​widefield_lightpath.png?​0x300}}The Nikon Eclipse Ti is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply and with Perfect Focus System for hardware focus control during long time-lapse acquisitions. Using either Metamorph or Nikon Elements software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. It is equipped with Andor Neo 5.5 monochrome cooled sCMOS camera ​ideal for time-lapse and tile-and-stitch microscopy. You can perform Z-stack acquisition and use [[https://​huygens.i3s.up.pt/​login.php|PPBI Huygens RM]] [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server to significantly improve image resolution even in thick samples. If don't want to use deconvolution,​ check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[colossus|Colossus]].+ 
 +The Nikon Eclipse Ti is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supplyand with Perfect Focus System for hardware focus control during long time-lapse acquisitions. Using NIS-Elements software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. It is equipped with an Andor Neo 5.5 monochrome cooled sCMOS camera. ​
  
   * **Microscope**:​ [[https://​www.microscope.healthcare.nikon.com/​en_EU/​products/​inverted-microscopes/​eclipse-ti-series|Nikon Eclipse Ti]]   * **Microscope**:​ [[https://​www.microscope.healthcare.nikon.com/​en_EU/​products/​inverted-microscopes/​eclipse-ti-series|Nikon Eclipse Ti]]
   * **Camera**: [[https://​andor.oxinst.com/​products/​scmos-camera-series/​neo-5-5-scmos|Andor Neo 5.5 sCMOS]]   * **Camera**: [[https://​andor.oxinst.com/​products/​scmos-camera-series/​neo-5-5-scmos|Andor Neo 5.5 sCMOS]]
  
-{{:​warning.png?​25|}} Data files older than **3 months** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.+{{:​warning.png?​25|}} Data files older than **3 months** will be automatically deleted on this system, please copy your data to the GIMM server using the desktop link.
  
 ===== System components ===== ===== System components =====
  
-==== Filtersets ​Turret 1 (top) ====+==== Filtersets ====
  
-^  Position ​ ^  Filterset ​ ​^ ​ Reference ​ ​^ ​ Excitation ​ ^  Dichroic ​ ^  Emission ​ ^+^  Position ​ ^  Filterset ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ​^ ​ Reference ​ ^
 |  1  |  Empty  ||||| |  1  |  Empty  |||||
-|  2  |  ​DAPI  |  MBE41300 ​ ​| ​ 340-380 nm  |  400 nm  |  435-485 nm  | +|  2  |  ​Blue  ​| ​ 340-380 nm  |  400 nm  |  ​<fc #007bff>435-485 nm</​fc> ​ |  MBE41300 ​ | 
-|  3  |  ​FITC  |  MBE44720 ​ ​| ​ 465-495 nm  |  505 nm  |  515-555 nm  | +|  3  |  ​Green  ​| ​ 465-495 nm  |  505 nm  |  ​<fc #70ff00>515-555 nm</​fc> ​ |  MBE44720 ​ | 
-|  4  |  ​TRITC  |  MBE45600 ​ ​| ​ 528-553 nm  |  565 nm  |  590-650 nm  | +|  4  |  ​Orange ​ ​| ​ 528-553 nm  |  565 nm  |  ​<fc #ff7700>590-650 nm</​fc> ​ |  MBE45600 ​ | 
-|  5  |  ​Cy5  |  2SK4CY50 ​ ​| ​ 608-648 nm  |  660 nm  |  672-712 nm  |+|  5  |  ​Red  ​| ​ 608-648 nm  |  660 nm  |  ​<fc #ff0000>672-712 nm</​fc> ​ |  2SK4CY50 ​ |
 |  6  |  Empty  ||||| |  6  |  Empty  |||||
- 
-==== Filtersets Turret 2 (bottom) ==== 
- 
-^  Position ​ ^  Filterset ​ ^ 
-|  1  |  Empty  | 
-|  2  |  Empty  | 
-|  3  |  Empty  | 
-|  4  |  Empty  | 
-|  5  |  Empty  | 
-|  6  |  Fura-2 ​ | 
  
 ==== Objectives ==== ==== Objectives ====
 ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
-|  10x  |  CFI Plan Fluor DLL Ph1  |  Air  |  0.30  |  16.00  |   ​[[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1835|MRH10101]] ​ | +|  ​<fc #fef042>10x</​fc> ​ ​| ​ CFI Plan Fluor DLL Ph1  |  Air  |  0.30  |  16.00  |   ​[[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1835|MRH10101]] ​ | 
-|  20x  |  CFI S Plan Fluor ELWD ADM Ph1  |  Air  |  0.45  |  6.90 - 8.20  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1813|MRH48230]] ​ | +|  ​<fc #0aa05c>20x</​fc> ​ ​| ​ CFI S Plan Fluor ELWD ADM Ph1  |  Air  |  0.45  |  6.90 - 8.20  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1813|MRH48230]] ​ | 
-|  40x  |  CFI CFI Plan Apochromat Lambda D  |  Air  |  0.95  |  0.21  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-179806|MRH70470]] ​ | +|  ​<fc #01b3f5>40x</​fc> ​ ​| ​ CFI CFI Plan Apochromat Lambda D  |  Air  |  0.95  |  0.21  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-179806|MRH70470]] ​ | 
-|  40x  |  CFI S Plan Fluor ELWD ADM Ph2  |  Air  |  0.60  |  2.80 - 3.60  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1814|MRH48430]] ​ | +|  ​<fc #01b3f5>40x</​fc> ​ ​| ​ CFI S Plan Fluor ELWD ADM Ph2  |  Air  |  0.60  |  2.80 - 3.60  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1814|MRH48430]] ​ | 
-|  60x  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  |+|  ​<fc #2c80c0>60x</​fc> ​  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  |
 |  100x  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  | |  100x  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  |
  