Previous revision
dragonfly [2025/01/14 11:46]
bioimaging [Microscope overview]
dragonfly [2025/01/14 16:07] (current)
bioimaging
Line 7: Line 7:
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
 <​b>​Location</​b>:​ [Oeiras] Room 0B05<​br> ​ <​b>​Location</​b>:​ [Oeiras] Room 0B05<​br> ​
-<​b>​Manufacturer</​b>:​ <​br>​ +<​b>​Manufacturer</​b>: ​<a href="​https://​andor.oxinst.com/"​ target="​_blank">​Oxford Institutes - Andor</​a> ​<​br>​ 
-<​b>​Model</​b>:​ <​br>​ +<​b>​Model</​b>: ​<a href="​https://​andor.oxinst.com/​products/​dragonfly-confocal-microscope-system"​ target="​_blank">​Andor Dragonfly 200</​a> ​<​br>​ 
-<​b>​Nickname</​b>:​ <​br>​ +<​b>​Nickname</​b>: ​Dragonfly ​<​br>​ 
-<​b>​Software</​b>:​ <​br>​ +<​b>​Software</​b>: ​Fusion ​<​br>​ 
-<​b>​Year</​b>: ​ <br>+<​b>​Year</​b>: ​2021 <br>
 <​b>​SN</​b>: ​ <br> <​b>​SN</​b>: ​ <br>
 &nbsp <br> &nbsp <br>
Line 35: Line 35:
 ===== System components ===== ===== System components =====
  
-^  ​Position ​ ​^  ​Filterset ​ ​^  ​Reference ​ ​^  ​Excitation ​ ​^  ​Dichroic ​ ​^  ​Emission ​ ^ +==== Lasers ==== 
-      |  |  |  |  |+ 
 + 
 +^  ​Laser  lines  ​^  ​Maximum power  ​^  ​Measured at objective @100% (mW)  ^ 
 + 405 nm  |  100 mW  |  7  | 
 +|  488 nm  |  100 mW  |  17  | 
 +|  561 nm  |  100 mW  |  20  | 
 +|  640 nm  |  100 mW  |  17  | 
 + 
 + 
 +==== Emission Filterwheel Spinning Disk ==== 
 +  
 + 
 +|  Filter “Name” ​ ​^  ​Transmission (nm)  ​^  ​Description (use for):  ^  CSU dichroic ​ ^ 
 + Quad (pos0)  ​ ​445/​521/​594/​698  ​ ​(faster switching) ​ ​| ​ ​405/​488/​561/​640 ​ 
 + 405 (pos1) ​ ​| ​ ​445/​46 nm  |  DAPI, Hoechst ​ |  405/​488/​561/​640 ​ | 
 +|  488 (pos2) ​ |  521/38 nm  |  GFP, FITC, Alexa488 ​ |  405/​488/​561/​640 ​ | 
 +|  561 (pos3) ​ |  594/43 nm  |  A568  |  405/​488/​561/​640 ​ | 
 +|  637 (pos4) ​ |  698/77 nm  |  Cy5, A633, A647  |  405/​488/​561/​640 ​ | 
 +|  561 extra (pos8) ​ |  606/64 nm  |  mCherry ​ |  405/​488/​561/​640 ​ | 
 +|  Pol (pos5) ​ |  All (50%)  |  TR-POLR-DIC-FWL ​ |  N/A-  |
  
  
 ==== Objectives ==== ==== Objectives ====
-^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ 
-|   ​| ​   |    |    |    |    
  
-==== Camera ​====+^  Objectives ​ ^  NA  ^  Imm.  ^  WD (mm)  ^  Max FoV (1600x1350px) ​ ^  ideal CSU pinhole ​ ^  Theor. Resol. um  ^ Pixel size in μm (1x / 2x zoom)  ^  PFS Compatible ​ ^ 
 +|  [[https://​www.microscope.healthcare.nikon.com/​pt_AMS/​products/​optics/​selector/​comparison/​-1825|10x]] ​ |  0.3  |  Dry  |  16  |  1.3mm  |  25um  |  1.07/​0.43 ​ |  1.020 / 0.510  |  Yes  | 
 +|  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-179802|20x]] ​ |  0.8  |  Dry  |  0.8  |  0.68mm ​ |  40um  |  0.40/​0.16 ​ |  0.510 / 0.255  |  Yes  | 
 +|  [[https://​www.microscope.healthcare.nikon.com/​pt_AMS/​products/​optics/​selector/​comparison/​-179806|40x]] ​ |  0.95  |  Dry  |  0.25-0.17 ​ |  0.34mm ​ |  40um  |  0.34/​0.13 ​ |  0.255 / 0.108* ​ |  Yes  | 
 +|  [[https://​www.microscope.healthcare.nikon.com/​pt_AMS/​products/​optics/​selector/​comparison/​-1855|60x]] ​ |  1.2  |  Water or Sil  |  0.31-0.28 ​ |  0.23mm ​ |  40um  |  0.27/​0.11 ​ |  0.170 / 0.085* ​ |  Yes  | 
 +|  [[https://​www.microscope.healthcare.nikon.com/​pt_AMS/​products/​optics/​selector/​comparison/​-1827|20x]]* ​ |  0.75  |  Multi  |  0.51-0.33 ​ |  0.68mm ​ |  25um  |  0.43/​0.17 ​ |  0.510 / 0.255  |  No  | 
 +|  [[https://​www.microscope.healthcare.nikon.com/​pt_AMS/​products/​optics/​selector/​comparison/​-5994|40x]]* ​ |  1.15  |  Water/​Sil ​ |  0.59-0.61 ​ |  0.34mm ​ |  40um  |  0.28/​0.11 ​ |  0.255 / 0.108* ​ |  Yes  | 
 +|  [[https://​www.microscope.healthcare.nikon.com/​pt_AMS/​products/​optics/​selector/​comparison/​-179810|100x]]* ​ |  1.45  |  Oil  |  0.13  |  0.13mm ​ |  40um  |  0.22/​0.09 ​ |  0.102 / 0.050* ​ |  Yes  | 
 + 
 +*Optional  
 + 
 +===== Turn On Procedure ​===== 
 + 
 +1. Turn on the Computer 
 + 
 +2. Turn on power bar #1 and then power bar #2. These power bars are behind the microscope table, on a rail just above the floor. 
 + 
 +3. Turn on laser key 
 + 
 +4. (Optional) Turn on incubator powerbar if you are planning to use the incubator and/or the CO2 
 + 
 +5. (Optional) Turn on the valves for CO2 and Nitrogen mixture, if you planning to use CO2 on your experiment 
 + 
 +6. Login in Agendo and open the Fusion software. 
 + 
 +7. Please ask assistance in advance, if you are going to use either the micropump system or/and the incubation setup. 
 + 
 + 
 +===== Turn Off Procedure ===== 
 + 
 +1.Close the software and save all your files to the “files1” server (shortcut in desktop). DO NOT CONNECT external disks/USB flash drives to the workstation! Check if you are the last user in Agendo and if you’re not, proceed to step 5. 
 + 
 +2. Turn the laser key to the Off position 
 + 
 +3. Turn off both the power bars in the back of the microscope table 
 + 
 +4. Clean any immersion objectives used. Use ONLY lens paper provided by staff, NEVER use other types of paper (eg lab towels) or cotton swabs. Apply a few drops of cleaning solution (EtOH) to the lens paper and gently swipe the tip of the objective in a linear motion without pressure (no circular motion). Repeat with a different part of the paper to remove all oil residue. 
 + 
 +5. Take your belongings (slides, pipettes, etc...); there'​s a glass disposal bin in the lab!
  
 +6. Log off your computer session.
  
 ---- ----