User Tools

Site Tools


andor_w1

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
andor_w1 [2025/01/15 15:05]
bioimaging [Objectives]
andor_w1 [2025/01/15 15:06] (current)
bioimaging [CSU Dichroics]
Line 45: Line 45:
 ^  Mag.  ^  Model  ^  Imm. ^  NA  ^  WD (mm)  ^  PFS?  ^  DIC?  ^  PhC?  ^  Reference ​ ^ ^  Mag.  ^  Model  ^  Imm. ^  NA  ^  WD (mm)  ^  PFS?  ^  DIC?  ^  PhC?  ^  Reference ​ ^
 |   ​4x ​ |  Nikon Plan DL   ​| ​ -  |  0.13  |  16.5  |  N  |  N/A  |  Ph1  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1834|MRH20045]] ​ |    |   ​4x ​ |  Nikon Plan DL   ​| ​ -  |  0.13  |  16.5  |  N  |  N/A  |  Ph1  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1834|MRH20045]] ​ |   
-|  10x  |  Nikon Plan DL  |  -  |  0.25  |  10.5  |  Yes  |  ​Not recommended ​ ​| ​ Ph1  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1701|MRL20102]] ​ |    +|  10x  |  Nikon Plan DL  |  -  |  0.25  |  10.5  |  Yes  |  ​No  ​| ​ Ph1  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1701|MRL20102]] ​ |    
-|  20x  |  Nikon Plan Fluor  |  -  |  0.5  |  2.1  |  Yes  |  ​Not recommended ​ ​| ​ Ph1  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1837|MRH10205]] ​ |   +|  20x  |  Nikon Plan Fluor  |  -  |  0.5  |  2.1  |  Yes  |  ​No  ​| ​ Ph1  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1837|MRH10205]] ​ |   
 |  20x  |  Nikon Plan Fluor  |  MImm  |  0.75  |  0.35  |  No  |  Yes (N1)  |  No  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1827|MRH07241]] ​ |    |  20x  |  Nikon Plan Fluor  |  MImm  |  0.75  |  0.35  |  No  |  Yes (N1)  |  No  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1827|MRH07241]] ​ |   
 |  40x  |  Plan Fluor  |  Oil  |  1.3  |  0.24  |  Yes  |  Yes (N2)  |  No  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​products/​optics/​selector/​comparison/​-1829|MRH01401]] ​ |    |  40x  |  Plan Fluor  |  Oil  |  1.3  |  0.24  |  Yes  |  Yes (N2)  |  No  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​products/​optics/​selector/​comparison/​-1829|MRH01401]] ​ |   
 |  63x  |  Nikon Plan APO VC  |  W  |  1.20  |  0.175  |  No  |  No  |  No  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1855|MRD07602]] ​ |    |  63x  |  Nikon Plan APO VC  |  W  |  1.20  |  0.175  |  No  |  No  |  No  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-1855|MRD07602]] ​ |   
- 
-* Not fabricated anymore ; * * LWD - Long Working Distance  ​ 
  
 ==== CSU Dichroics ==== ==== CSU Dichroics ====
Line 58: Line 56:
 |  1  |  [[https://​www.idex-hs.com/​store/​product-detail/​ff685_di02_25x36/​fl-007099|IR mirror]] ​ |  685LP  | |  1  |  [[https://​www.idex-hs.com/​store/​product-detail/​ff685_di02_25x36/​fl-007099|IR mirror]] ​ |  685LP  |
 |  2  |  [[https://​www.idex-hs.com/​store/​product-detail/​di01_t405_488_568_647_13x15x0_5/​fl-006984|LD 405/​488/​561/​640]] ​ |  Quad mirror 80-85% transmission| |  2  |  [[https://​www.idex-hs.com/​store/​product-detail/​di01_t405_488_568_647_13x15x0_5/​fl-006984|LD 405/​488/​561/​640]] ​ |  Quad mirror 80-85% transmission|
-|  3  |  [[https://​www.chroma.com/​products/​parts/​zt405-488-561-640rpc|ZT 405/​488/​561/​640]] ​ |  Quad mirror >95% transmission |+|  3  |  [[https://​www.chroma.com/​products/​parts/​zt405-488-561-640rpc|ZT 405/​488/​561/​640]] ​ |  Quad mirror >95% transmission ​"​HE" ​|
  
  
andor_w1.1736949951.txt.gz · Last modified: 2025/01/15 15:05 by bioimaging