User Tools

Site Tools


about

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
about [2025/08/04 12:32]
bioimaging
about [2026/01/05 19:26] (current)
bioimaging
Line 46: Line 46:
 <​html>​ <​html>​
 <img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=bioimaging_systems_2025.gif"​ width=340 align=left>​ <img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=bioimaging_systems_2025.gif"​ width=340 align=left>​
-</​html>​The ​facility ​houses 29 microscopy systems, including five inverted laser point scanning confocal microscopes with motorized stage, piezo and super-resolution detector prepared for live cell imaging [3x [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​confocal-microscopes/​lsm-980-with-airyscan-2.html|ZEISS LSM 980 with Airyscan 2]] (one of them with a 32-channel spectral detector), [[zeiss_lsm_900|ZEISS LSM 900 with Airyscan 2]], [[zeiss_lsm_880|ZEISS LSM 880 with Airyscan]]),​ and one fully automated inverted widefield and point scanning confocal microscope optimized for high-throughput live imaging in well-plates ([[zeiss_celldiscoverer_7|ZEISS Celldiscoverer 7 with LSM 900]])], six inverted spinning disk confocal microscopes with motorized stage, piezo and EM-CCD/​sCMOS cameras prepared for live cell imaging [3x [[https://​www.intelligent-imaging.com/​marianas|3i Marianas SDC]] (one of them with TIRF and in a BSL2 room), [[https://​andor.oxinst.com/​products/​dragonfly-confocal-microscope-system|Andor Dragonfly SDC]], [[leica_sdc|Leica Spinning Disk Confocal]], and [[zeiss_cell_observer_sd|ZEISS Cell Observer SD]]], three light sheet microscopes prepared for water and clearing media immersion imaging (2x ZEISS Lightsheet Z.1, and [[blaze|Miltenyi UltraMicroscope Blaze]]), one multi-photon microscope ([[prairie|Prairie Multiphoton]]),​ seven fully motorized inverted widefield microscopes with cooled CCD/CMOS cameras ([[https://​www.agilent.com/​en/​product/​cell-analysis/​cell-imaging-microscopy/​cell-imaging-multimode-readers/​biotek-cytation-5-cell-imaging-multimode-reader-1623202|Agilent Cytation 5]] multimode reader with incubation, [[deltavision|Deltavision OMX-SIM]] super-resolution with incubation and SIM-TIRF, [[nikon_eclipse_ti|Nikon Eclipse Ti]] with stage top incubation ​and a Ionoptix calcium and contractility measurement system, [[nikon_htm-hcs|Nikon HTM-HCS]] with incubation, [[zeiss_cell_observer|ZEISS Cell Observer]] with a large cage incubator and an Akoya PhenoCycler for spatial phenotyping,​ [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-imager-2-for-life-science-research.html|ZEISS Imager with Apotome 2]] with 8 slide carrier, and ZEISS Axiovert 200M), one automated slide scanner for fluorescence and brightfield scanning up to 100 slides ([[https://​www.zeiss.com/​microscopy/​en/​products/​imaging-systems/​axioscan-for-biology.html|ZEISS Axioscan 7]]), two fluorescence stereo microscopes with CCD/CMOS cameras ([[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​stereo-and-zoom-microscopes/​axio-zoom-v16-for-biology.html|ZEISS Axio Zoom.V16]], and [[oeiras_zeiss_lumar_v12|ZEISS Stereo Lumar.V12]]) and other imaging resources such as a brightfield microscope ([[leica_dm2500|Leica DM2500]]) and a bioluminescence/​fluorescence imaging system ([[ivis_lumina|IVIS Lumina]]). There are also high spec workstations for image analysis and processing ([[amira|Amira]],​ [[chronos|Chronos]],​ [[huygens|Huygens]],​ [[imaris|Imaris]],​ [[z2_workstation|Z2]],​ [[z3_workstation|Z3]],​ and ZEISS LSM 980-32 Workstations). ​+</​html>​The ​Platform ​houses 29 microscopy systems, including five inverted laser point scanning confocal microscopes with motorized stage, piezo and super-resolution detector prepared for live cell imaging [3x [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​confocal-microscopes/​lsm-980-with-airyscan-2.html|ZEISS LSM 980 with Airyscan 2]] (one of them with a 32-channel spectral detector), [[zeiss_lsm_900|ZEISS LSM 900 with Airyscan 2]], [[zeiss_lsm_880|ZEISS LSM 880 with Airyscan]]),​ and one fully automated inverted widefield and point scanning confocal microscope optimized for high-throughput live imaging in well-plates ​that integrates with an advanced robotic loader, automated liquid handler, and incubator to enable high-throughput,​ fully automated workflows for live-cell imaging ​([[zeiss_celldiscoverer_7|ZEISS Celldiscoverer 7 with LSM 900]])], six inverted spinning disk confocal microscopes with motorized stage, piezo and EM-CCD/​sCMOS cameras prepared for live cell imaging [3x [[https://​www.intelligent-imaging.com/​marianas|3i Marianas SDC]] (one of them with TIRF and in a BSL2 room), [[https://​andor.oxinst.com/​products/​dragonfly-confocal-microscope-system|Andor Dragonfly SDC]], [[leica_sdc|Leica Spinning Disk Confocal]], and [[zeiss_cell_observer_sd|ZEISS Cell Observer SD]]], three light sheet microscopes prepared for water and clearing media immersion imaging (2x ZEISS Lightsheet Z.1, and [[blaze|Miltenyi UltraMicroscope Blaze]]), one multi-photon microscope ([[prairie|Prairie Multiphoton]]),​ seven fully motorized inverted widefield microscopes with cooled CCD/CMOS cameras ([[https://​www.agilent.com/​en/​product/​cell-analysis/​cell-imaging-microscopy/​cell-imaging-multimode-readers/​biotek-cytation-5-cell-imaging-multimode-reader-1623202|Agilent Cytation 5]] multimode reader with incubation, [[deltavision|Deltavision OMX-SIM]] super-resolution with incubation and SIM-TIRF, [[nikon_eclipse_ti|Nikon Eclipse Ti]] with stage top incubation, [[nikon_htm-hcs|Nikon HTM-HCS]] with incubation ​and a Ionoptix calcium and contractility measurement system, [[zeiss_cell_observer|ZEISS Cell Observer]] with a large cage incubator and an Akoya PhenoCycler for spatial phenotyping,​ [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-imager-2-for-life-science-research.html|ZEISS Imager with Apotome 2]] with 8 slide carrier, and ZEISS Axiovert 200M), one automated slide scanner for fluorescence and brightfield scanning up to 100 slides ([[https://​www.zeiss.com/​microscopy/​en/​products/​imaging-systems/​axioscan-for-biology.html|ZEISS Axioscan 7]]), two fluorescence stereo microscopes with CCD/CMOS cameras ([[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​stereo-and-zoom-microscopes/​axio-zoom-v16-for-biology.html|ZEISS Axio Zoom.V16]], and [[oeiras_zeiss_lumar_v12|ZEISS Stereo Lumar.V12]]) and other imaging resources such as a brightfield microscope ([[leica_dm2500|Leica DM2500]]) and a bioluminescence/​fluorescence imaging system ([[ivis_lumina|IVIS Lumina]]). There are also high spec workstations for image analysis and processing ([[amira|Amira]],​ [[chronos|Chronos]],​ [[huygens|Huygens]],​ [[imaris|Imaris]],​ [[z2_workstation|Z2]],​ [[z3_workstation|Z3]],​ and ZEISS LSM 980-32 Workstations). ​
  
 The Bioimaging systems are available on the [[https://​gimm.agendoscience.com|online booking system]] for trained researchers 7 days a week and 24 hours per day. User training in each particular system is mandatory, even for researchers with previous microscopy experience. The Bioimaging systems are available on the [[https://​gimm.agendoscience.com|online booking system]] for trained researchers 7 days a week and 24 hours per day. User training in each particular system is mandatory, even for researchers with previous microscopy experience.
about.1754303550.txt.gz ยท Last modified: 2025/08/04 12:32 by bioimaging