 <​b>​Year</​b>:​ 2016 <br> <​b>​Year</​b>:​ 2016 <br>
 <​b>​SN</​b>:​ 2811000267 <br> <​b>​SN</​b>:​ 2811000267 <br>
 +&nbsp <br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
Line 20: Line 21:
  <​br>​  <​br>​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss LSM 880 Usage Statistics</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss LSM 880 Usage Statistics</​a>​
-&nbsp </br> 
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_repair"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=repair-icon.gif"​ width=16>​ Zeiss LSM 880 Repair History</​a>​ 
  </​p>​  </​p>​
 </td> </td>
Line 30: Line 29:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-The Zeiss LSM 880 with Airyscan is a //confocal point-scanning microscope//​ able to generate high-resolution three-dimensional images of thick specimens with high sensitivity and low photodamage. It is an inverted microscope specially suitable for live cell imaging and photobleaching experiments,​ equipped with a large size incubator for temperature control and CO2 supply. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan]] 32 channel area detector is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (140 nm laterally and 400 nm axially, at 488 nm). Its scanning unit further includes two PMT detectors (one of them cooled) as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional PMT).  It is equipped with lasers from violet to far red (405, 458, 488, 514, 561, 594 and 633 nm excitation wavelengths). With this system you can perform optical sectioning of fluorescent samples which are too thick for a widefield system such as the [[zeiss_cell_observer_wf|Zeiss Cell Observer WF]] or the [[zeiss_axiovert_200m|Zeiss Axiovert 200M]]. Image resolution with Airyscan is higher than the [[zeiss_lsm_710|Zeiss LSM 710]] and detection sensitivity is also higher than faster confocal systems such as the spinning disk [[3i_marianas_sdc|3i Marianas SDC]] or the //line scanning// [[zeiss_lsm_7_live|Zeiss LSM 7 Live]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]].+{{  :​airyscan.jpg?​0x380}} ​The Zeiss LSM 880 with Airyscan is a //confocal point-scanning microscope//​ able to generate high-resolution three-dimensional images of thick specimens with high sensitivity and low photodamage. It is an inverted microscope specially suitable for live cell imaging and photobleaching experiments,​ equipped with a large size incubator for temperature control and CO2 supply ​and with Definite Focus for hardware focus control during long time-lapse acquisitions. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan]] 32 channel area detector is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (140 nm laterally and 400 nm axially, at 488 nm). Its scanning unit further includes two PMT detectors (one of them cooled) as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional PMT).  It is equipped with lasers from violet to far red (405, 458, 488, 514, 561, 594 and 633 nm excitation wavelengths). With this system you can perform optical sectioning of fluorescent samples which are too thick for a widefield system such as the [[zeiss_cell_observer_wf|Zeiss Cell Observer WF]] or the [[zeiss_axiovert_200m|Zeiss Axiovert 200M]]. Image resolution with Airyscan is higher than the [[zeiss_lsm_710|Zeiss LSM 710]] and detection sensitivity is also higher than faster confocal systems such as the spinning disk [[3i_marianas_sdc|3i Marianas SDC]] or the //line scanning// [[zeiss_lsm_7_live|Zeiss LSM 7 Live]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. 
 + 
 +{{info.gif?​|}} Click on the image on the left to see the light path in higher detail
  
 ===== Booking Rules ===== ===== Booking Rules =====
Line 90: Line 91:
   * **Make sure that there really is another user going to use the microscope.**   * **Make sure that there really is another user going to use the microscope.**
 Else: Else:
-  * Turn off the lasers on ''​ZEN''​+  * Turn off the lasers on **ZEN**
   * Clean up any objective were you used immersion oil.   * Clean up any objective were you used immersion oil.
   * Exit the software, shut down the computer.   * Exit the software, shut down the computer.