User Tools

Site Tools


zeiss_lsm_880

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
zeiss_lsm_880 [2016/04/05 00:32]
bioimaging [LASERs]
zeiss_lsm_880 [2020/02/28 00:35]
bioimaging [Microscope Turn On Procedure]
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_name.jpg">+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_name_new.png">
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki.jpg" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_new.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_new.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_map.jpg">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif" width=15>​ 47217) <​br> ​+<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_map_new.png">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png" width=15>​ 47217) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​
-<​b>​Model</​b>: ​<a href="​http://​www.zeiss.com/​microscopy/​en_de/​products/​confocal-microscopes/​lsm-880-with-airyscan-.html"​ target="​_blank">​LSM 880 with Airyscan</​a><​br>​+<​b>​Model</​b>:​ LSM 880 with Airyscan<​br>​ 
 +<​b>​Nickname</b>: "​880"​<br>
 <​b>​Software</​b>:​ ZEN 2.1 (black) <br> <​b>​Software</​b>:​ ZEN 2.1 (black) <br>
 <​b>​Year</​b>:​ 2016 <br> <​b>​Year</​b>:​ 2016 <br>
Line 15: Line 16:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=ZEISSLSM8&​rid=128"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss LSM 880 Booking</​a>​+&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​128"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss LSM 880 Booking</​a>​
  <​br> ​  <​br> ​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss LSM 880 Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss LSM 880 Quality Control</​a>​
  <​br>​  <​br>​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss LSM 880 Usage Statistics</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss LSM 880 Usage Statistics</​a>​
-&nbsp </br> 
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_repair"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=repair-icon.gif"​ width=16>​ Zeiss LSM 880 Repair History</​a>​ 
  </​p>​  </​p>​
 </td> </td>
Line 30: Line 29:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-The Zeiss LSM 880 with Airyscan is a //confocal point-scanning microscope//​ able to generate high-resolution three-dimensional images of thick specimens with high sensitivity and low photodamage. It is an inverted microscope ​specially ​suitable for live cell imaging and photobleaching experiments,​ equipped with a large size incubator for temperature control and CO2 supply. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan]] 32 channel area detector is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (140 nm laterally and 400 nm axially, at 488 nm). Its scanning unit further includes two PMT detectors (one of them cooled) as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional PMT).  It is equipped with lasers from violet to far red (405, 458, 488, 514, 561, 594 and 633 nm excitation wavelengths). With this system you can perform optical sectioning of fluorescent samples which are too thick for a widefield system such as the [[zeiss_cell_observer_wf|Zeiss Cell Observer ​WF]] or the [[zeiss_axiovert_200m|Zeiss Axiovert 200M]]. Image resolution with Airyscan is higher than the [[zeiss_lsm_710|Zeiss LSM 710]] and detection sensitivity is also higher than faster confocal systems such as the spinning ​disk [[3i_marianas_sdc|3i Marianas SDC]] or the //line scanning// ​[[zeiss_lsm_7_live|Zeiss ​LSM 7 Live]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]].+{{  :​airyscan_beampath.png?​400}} ​The Zeiss LSM 880 with Airyscan is a //confocal point-scanning microscope//​ able to generate high-resolution three-dimensional images of thick specimens with high sensitivity, high speed and low photodamage. It is an inverted microscope ​especially ​suitable for live cell imaging and photobleaching experiments,​ equipped with a large size incubator for temperature control and CO2 supply ​and with Definite Focus for hardware focus control during long time-lapse acquisitions. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan]] 32 channel area detector is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (140 nm laterally and 400 nm axially, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=ln6VUmLzLLc|Fast Mode]], which enables parallel excitation and detection of four image pixels. The result is a speed improvement by a factor of four, while maintaining the sensitivity of Airyscan and 1.5x resolution improvement. Its scanning unit further includes two PMT detectors (one of them cooled) as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional PMT). It is equipped with lasers from violet to far red (405, 458, 488, 514, 561, 594 and 633 nm excitation wavelengths). ​ 
 +{{::​fast_airyscan.png?​420 ​ }}With this system you can perform optical sectioning of fluorescent samples which are too thick for a widefield system such as the [[zeiss_cell_observer|Zeiss Cell Observer]] or the [[zeiss_axiovert_200m|Zeiss Axiovert 200M]]. Image resolution with Airyscan is higher than the [[zeiss_lsm_710|Zeiss LSM 710]] and detection sensitivity is also higher than the spinning ​disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss ​Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]
 + 
 +{{:​info.png?​25|}} Click [[https://​imm.medicina.ulisboa.pt/​facility/​bioimaging/​lib/​exe/​fetch.php?​cache=&​media=airyscan.jpg|here]] to see the system beam path in higher detail 
 + 
 +{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
  
 ===== Booking Rules ===== ===== Booking Rules =====
-The Zeiss LSM 710 booking is divided in three daily slots:+The Zeiss LSM 880 booking is divided in three daily slots:
 |  9:00 to 13:00  |  13:00 to 17:00  |  17:00 to 21:00  | |  9:00 to 13:00  |  13:00 to 17:00  |  17:00 to 21:00  |
  
Line 43: Line 47:
   - Users must indicate which lasers they are going to use in the booking Description field   - Users must indicate which lasers they are going to use in the booking Description field
   - Users must indicate if they will use the incubator in the booking Description field (write down 37C INCUBATOR)   - Users must indicate if they will use the incubator in the booking Description field (write down 37C INCUBATOR)
-  - Users must write their internal extension phone number in the booking Description field 
  
 ===== System components ===== ===== System components =====
Line 56: Line 59:
  
 ==== Objectives ==== ==== Objectives ====
-^  Magnification ​  ​^ ​ Model  ^  ​Type  ​^ ​ NA  ^  WD (mm)  ^ +^  Magnification ​  ​^ ​ Model  ^  ​Immersion ​ ​^ ​ NA  ^  WD (mm)  ​^ ​ Reference ​ ^ 
-|  10x  |  [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420340-9901-000|EC Plan-Neofluar]] ​ |  ​Dry  ​|  ​0.30  ​|  ​5. +|  10x  ​| ​ EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]]  ​
-|  ​20x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420650-9901-000|Plan-Apochromat]] ​ |  ​Dry  ​|  ​0.80  ​|  ​0.55  +|  ​20x  ​|  ​Plan-Apochromat ​ ​|  ​Air  |  0.80  ​|  ​0.55  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]]  ​
-|  ​40x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440452-9903-000|EC Plan-Neofluar]]  |  Oil  |  1.30  ​| ​ 0.20  | +|  ​40x  ​|  ​C-Apochromat Corr  ​|  ​Water  |  1.20  ​|  ​0.28  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421767-9970-000/​Objective-C-Apochromat-40x-1.20-W-Corr-M27|421767-9970-000]]  | 
-|  63x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440762-9904-000|Plan-Apochromat]]  |  Oil  |  ​1.40  ​ ​0.19 ​ |+|  63x  |  Plan-Apochromat DIC  ​| ​ Oil  |  1.40  ​| ​ 0.19  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ | 
  
 **Upon request:** **Upon request:**
  
-^  Magnification ​  ​^ ​ Model  ^  ​Type  ​^ ​ NA  ^  WD (mm)  ^ +^  Magnification ​  ​^ ​ Model  ^  ​Immersion ​ ​^ ​ NA  ^  WD (mm)  ​^ ​ Reference ​ ^ 
-|  25x  |  [[https://​www.micro-shop.zeiss.com/​?​s=129353259d52f12&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420852-9972-000|LCI Plan-NeoFluar]]  |  ​Oil/​Glyc/​W ​ ​|  ​0.8  ​| ​ 0.21  +|  25x  ​| ​ LCI Plan-Neofluar Corr DIC  |  Oil/​Glyc/​W ​ |  0.80  |  0.21  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420852-9973-000/Objective-LCI-Plan-Neofluar-25x-0.8-Imm-Corr-DIC-M27|420852-9972-000]]  ​
-|  ​100x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440782-9902-000|Plan-Apochromat]] ​ |  Oil  |  1.40  ​| ​ 0.17  | +|  ​40x  ​|  ​Plan-Apochromat Corr  |  Dry  ​| ​ 0.95  ​|  ​0.25  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]]  | 
 +|  100x  |  α Plan-Apochromat DIC  ​| ​ Oil  |  1.46  ​| ​ 0.11  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420792-9800-000/​Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27|420792-9800-000]] ​ |
 ==== Filtersets (Ocular) ==== ==== Filtersets (Ocular) ====
  
 ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^ ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^
-|  1  |  Green  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1031-346&o=|FS38]]  |  450-490 nm  |  500-550 nm  |+|  1  |  Green  |  [[https://​www.micro-shop.zeiss.com/?​s=7139069fdc79c&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489038-9901-000&o=|FS38HE]]  |  450-490 nm  |  500-550 nm  |
 |  2  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1114-101&​o=|FS43]] ​ |  533-558 nm  |  570-640 nm  | |  2  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1114-101&​o=|FS43]] ​ |  533-558 nm  |  570-640 nm  |
 |  3  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ |  G 365 nm  |  420-470 nm  | |  3  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ |  G 365 nm  |  420-470 nm  |
Line 79: Line 83:
   * Turn on the two switches: ''​SYSTEMS/​PC''​ and ''​COMPONENTS''​   * Turn on the two switches: ''​SYSTEMS/​PC''​ and ''​COMPONENTS''​
 {{zeiss_lsm_880_1.jpg?​100}} {{zeiss_lsm_880_1.jpg?​100}}
-  * Turn the metal halide power source ​on (if needed) +  * Turn on the computer 
-{{:​bioimaging:​halide_710.jpg?​80}} +  * Login in to Windows ​(Bioimaging User
-  * Turn the Ar laser on using the key (if needed) +  * Start the **ZEN Black** ​software
-{{:​bioimaging:​laser_key_710.jpg?​100}} +
-  * Turn the computer ​on +
-  * Login with your unit account +
-  * Wait for network icon to change to ''​connected''​ state +
-  * Switch the Ar laser from ''​idle''​ ton ''​run'' ​(don't change the ''​current''​) +
-{{:​bioimaging:​laser_run_710.jpg?​100}} +
-  * Start the ''​ZEN 2009'' ​software+
  
 ===== Microscope Turn Off Procedure ===== ===== Microscope Turn Off Procedure =====
-If there'​s ​another user for this microscope in the next hour+If there is another user for this microscope in the __next hour__
-  * Close the software, leave the lasers on an log off the computer +  * Exit the ZEN software, leave the lasers on 
-  * Clean up any objective were you used immersion ​oil. +  * Log off the computer 
-  * **Make sure that there really is another user going to use the microscope.**+  * Clean up immersion ​objectives
 Else: Else:
-  * Turn off the 561 nm laser and incubator in the software (if used) +  * Turn off the lasers on **ZEN** 
-  ​Switch the Ar laser from ''​run''​ to ''​idle''​ (if used) +  * Clean up immersion ​objectives 
-  ​Turn off the Ar laser using the key (if used) +  * Exit the ZEN software 
-  * Clean up any objective were you used immersion ​oil. +  * Shutdown ​the computer 
-  * Exit the software, shut down the computer. +  * Turn off the two switches ''​SYSTEMS/​PC''​ and ''​COMPONENTS''​ 
-  * Turn off the metal halide lamp +  ​* **Wait 5 min. for Ar laser to cool down** 
-  * Turn off the main switches ''​SYSTEMS/​PC''​ and ''​COMPONENTS''​ +  * Turn off the ''​MAIN SWITCH''​ 
-  * Wait 5 min. for Ar laser cooldown +
-  * Turn off the ''​MAIN SWITCH''​.+
 ---- ----
 [[resources|Back to the Resources page]] [[resources|Back to the Resources page]]
zeiss_lsm_880.txt · Last modified: 2024/01/28 11:47 by bioimaging