User Tools

Site Tools


zeiss_lsm_880

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
Next revision Both sides next revision
zeiss_lsm_880 [2016/03/29 17:18]
bioimaging created
zeiss_lsm_880 [2022/09/01 16:28]
bioimaging
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_name.jpg">+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_name_new.png">
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki.jpg" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_2022.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_2022.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_map.jpg">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif" width=15>​ 47217) <br>  +<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_map_new.png">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png" width=15>​ 47217) <br>  
-<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​ +<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​ 
-<​b>​Model</​b>:​ <a href="http://www.zeiss.com/microscopy/​en_de/​products/​confocal-microscopes/​lsm-880-with-airyscan-.html"​ target="​_blank">​LSM 880 with Airyscan</​a><​br>​ +<​b>​Model</​b>:​ <a href="https://www.youtube.com/watch?v=sGTNBXq8omg">​LSM 880 with Airyscan</​a> ​(click for Zeiss webinar) <​br>​ 
-<​b>​Software</​b>:​ ZEN 2.(black) <br>+<​b>​Nickname</​b>:​ "​880"​<​br>​ 
 +<​b>​Software</​b>:​ ZEN 2.3 SP1 (black ​edition) <br>
 <​b>​Year</​b>:​ 2016 <br> <​b>​Year</​b>:​ 2016 <br>
 <​b>​SN</​b>:​ 2811000267 <br> <​b>​SN</​b>:​ 2811000267 <br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=ZEISS5LIV&​rid=12"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss LSM 880 Booking</​a+&nbsp <br
- <​br>​  +&​nbsp ​<​br>​ 
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_7_live_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss LSM 7 Live Quality Control</​a>​ +&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss LSM 880 Quality Control</​a>​
- <​br>​ +
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_7_live_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss LSM 7 Live Usage Statistics</​a>​ +
-&nbsp </​br>​ +
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_7_live_repair"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=repair-icon.gif"​ width=16>​ Zeiss LSM 7 Live Repair History</a>+
  <​br>​  <​br>​
-&rarr; <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?media=manual_lsm_5_live.pdf"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=adobe_pdf_icon.png">​ Zeiss LSM 5 Live Operating Manual</​a>​ +&rarr; <a href="/​facility/​bioimaging/​doku.php?id=zeiss_lsm_880_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss LSM 880 Usage Statistics</​a>​ 
-&​nbsp ​</p>+ </​p>​
 </td> </td>
 </tr> </tr>
Line 31: Line 28:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-The Zeiss LSM 7 Live //confocal line-scanning microscope// is a fast imaging system ​able to analyze ​high-speed processes with a time resolution of just a few microseconds. It is an upright ​microscope equipped with water dipping objectives specially suited ​for live samples in aqueous media. The scanning unit uses a laser beam with a rectangular cross-section to [[http://​www.nature.com/nmeth/journal/v3/n11/thumbs/nmeth971-F2.jpg|illuminate a whole line in the sample]], instead ​of a single point. This makes image acquisition ​by its array CCD detectors faster than conventional PMT light detection but it also lowers ​the Z-resolution ​due to the usage of slits instead ​of conventional ​pinholesNote that the system ​is equipped with two lasers (488 and 561 nm) but dual color imaging is not advised since there are no bandpass filters in the system (channel crosstalk is likely to occur). A UV laser controlled by galvanometric mirrors is available for precise ablation in user-defined regions of interest. The spatial resolution of this system ​is not as high as //​point-scanning confocal ​system// such as the [[zeiss_lsm_880|Zeiss ​LSM 880]] or [[zeiss_lsm_710|Zeiss LSM 710]] but it is much faster than these two systems, achieving scanning speeds which may be even higher than the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk if the acquisition is performed only in a few lines. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]].+{{  :​confocal_pinhole.png?​350}} ​The Zeiss LSM 880 with Airyscan is a [[https://www.youtube.com/​watch?​v=rTkjQ6Q0p5I|point-scanning ​confocal ​microscope]] able to generate ​high-resolution ​three-dimensional images ​of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted ​microscope ​especially suitable for live cell imaging and photobleaching experiments, ​equipped with a large cage incubator and a stage top incubator ​for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. The stage is motorized and furthermore equipped ​with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions. Its [[http://​www.zeiss.com/content/dam/Microscopy/Products/laser-scan/​LSM%20880/zeiss-lsm880-airyscan-principle-672.jpg|Airyscan]] with 32 concentrically arranged GaAsP detection elements is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (140 nm laterally and 400 nm axially, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=ln6VUmLzLLc|Fast Mode]], which enables parallel excitation and detection ​of four image pixels. The result is a speed improvement ​by a factor of four, while maintaining ​the sensitivity of Airyscan and 1.5x resolution ​improvement. Its scanning unit further includes two PMT detectors (one of them cooled) as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional ​PMT)It is equipped with lasers ​from violet to far red (405, 458, 488, 514, 561, 594 and 633 nm excitation wavelengths). With this system ​you can perform optical sectioning of fluorescent samples which are too thick for widefield ​system such as the [[zeiss_cell_observer|Zeiss ​Cell Observer]]. Image resolution with Airyscan is higher than the [[zeiss_lsm_710|Zeiss LSM 710]] and detection sensitivity ​is also higher than the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[colossus|Colossus]].
  
-{{info.gif?|}} **If you are going to use the 561 nm laser please write '​561'​ in the Event Field name**+{{  ::​fast_airyscan.png?600  ​}}
  
-===== System components =====+{{:​info.png?​25|}} Click [[https://​imm.medicina.ulisboa.pt/​facility/​bioimaging/​lib/​exe/​fetch.php?​cache=&media=airyscan.jpg|here]] to see the system beam path in detail
  
-==== LASERs ==== +{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
-^  Laser Unit  ^  Wavelength ​ ^  Maximum Power  ^  Current Status ​ ^ +
-|  Sapphire 488-100 ​ |  488 nm  |  100 mW  |  ok  | +
-|  DPSS 561-40 ​ |  561 nm  |  40 mW  |  ok  ​|+
  
-==== Objectives ​==== +===== Additional information ​=====
-^  Magnification ​ ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^ +
-|  10x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440039-0000-000|W Achroplan Ph1]]  |  Water dipping ​ |  0.30  |  3.1  | +
-|  10x  |  [[https://​www.micro-shop.zeiss.com/?​s=2065696c9e13e&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440330-0000-000|Plan-Neofluar]] ​ |  Dry  |  0.30  |  5.5  | +
-|  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=421452-9900-000|W Plan-Apochromat]] ​ |  Water  |  1.00  |  1.8  | +
-|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440090-9901-000|W Achroplan]] ​ |  Water dipping ​ |  0.80  |  3.6  | +
-|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar Ph3]]  |  Oil  |  1.30  |  0.20  |+
  
-==== Filtersets ​(Ocular====+  * [[https://​www.youtube.com/​watch?​v=sGTNBXq8omg|ZEISS Webinar: LSM 880 with Airyscan - Revolutionize Your Confocal Imaging (video)]] 
 +  * [[https://​www.youtube.com/​watch?​v=VuxgaKDa_DU|ZEISS Webinar: Fast Mode for ZEISS LSM 880 with Airyscan ​(video)]]
  
-^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^ +===== Booking Rules ===== 
-|  2  |  Green  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&p=us&f=f&a=v&b=f&id=488010-9901-000&​o=|FS10]] ​ |  450-490 nm  |  515-565 nm  | +  ​- ​**Users** can book at maximum **8 hours per week** 
-|  3  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488015-0000-000&​o=|FS15]] ​ |  540-552 nm  |  > 590 nm  | +  ​- This usage restriction does not apply for **weekends** and for working days **before 9:00** and **after 21:00** 
- 4  |  Blue (for ablation*)  |  [[https://www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]]  ​| ​ none  |  420-470 nm  | +  - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**.
-Excitation filter has been removed+
  
-==== Filter and Dichroic sets ==== +===== System components =====
-|  {{zeiss5livefilters0.jpg?​100}} ​ |  {{zeiss5livefilters1.jpg?​100}} ​ | +
-|  Main configuration ​ |  Emission filters ​ |+
  
-===== Microscope Turn On Procedures =====+==== LASERs ​==== 
 +^  Laser Unit  ^  Wavelength ​ ^  Maximum Power  ^ 
 +|  Diode 405-30 ​ |  405 nm  |  30 mW  | 
 +|  Argon  |  458, 488 and 514 nm  |  25 mW  | 
 +|  DPSS 561-20 ​ |  561 nm  |  20 mW  | 
 +|  HeNe594 ​ |  594 nm  |  2 mW  | 
 +|  HeNe633 ​ |  633 nm  |  5 mW  |
  
-==== Normal Operation ​====+==== Objectives ​==== 
 +^  Magnification ​  ​^ ​ Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ 
 +|  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ | 
 +|  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]] ​ | 
 +|  40x  |  C-Apochromat Corr  |  Water  |  1.20  |  0.28  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421767-9970-000/​Objective-C-Apochromat-40x-1.20-W-Corr-M27|421767-9970-000]] ​ | 
 +|  40x  |  LD C-Apochromat Corr  |  Water  |  1.10  |  0.62  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421867-9970-000/​Objective-LD-C-Apochromat-40x-1.1-W-Corr-M27|421867-9970-000]] ​ | 
 +|  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ |
  
-  * The system must be turned on **30 min** before usage. 
-    * To start it turn on the two main switches: ''​SYSTEM/​PC''​ and ''​COMPONENTS''​ 
-{{7live_switches.jpg?​100|}} 
-  * Login to the computer, wait for the network icon to change to ''​connected''​ state 
-  * Start the **ZEN 2009** software. 
-**After the 30 min:** 
-  * Turn on the metal halide lamp (white box to the left of the microscope). 
-{{7live_excite.jpg?​100|}} 
-  * You may now start using the system. 
  
-==== Live Imaging / Time Lapse Operation ====+**Upon request:**
  
-  ​* The system must be turned on **2 hours** before usage (in order to properly warm up scanning mirrors). +^  Magnification ​  ​^  Model  ^  Immersion ​ ^  NA  ^  WD (mm ​^ ​ Reference ​ ^ 
-    * To start it turn on the two main switches: **SYSTEM/PC** and **COMPONENTS** +|  25x  |  LCI Plan-Neofluar Corr DIC  |  Oil/Glyc/​W ​  0.80  |  0.21  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420852-9973-000/​Objective-LCI-Plan-Neofluar-25x-0.8-Imm-Corr-DIC-M27|420852-9972-000]] ​ | 
-  * Login to the computer, wait for the network icon to change to ''​connected''​ state + 40x  |  Plan-Apochromat Corr  |  Dry  |  0.95  |  0.25  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/​Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]] ​ | 
-  * Start the **ZEN 2009** software. +==== Filtersets (Ocular) ====
-**After the 2 hours:** +
-  ​* Turn on the metal halide lamp (white box to the left of the microscope). +
-  * You may now start using the system.+
  
-===== Microscope Turn Off procedures ​===== +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^ 
-If there'​s another user for this microscope in the next two hours: +|  1  |  Green  |  [[https://​www.micro-shop.zeiss.com/?​s=7139069fdc79c&​l=en&p=us&f=f&a=v&b=f&id=489038-9901-000&​o=|FS38HE]] ​  450-490 nm   495 nm   500-550 nm  | 
-  * Exit the **ZEN 2009** software, leave the lasers on and log off the computer.  + 2  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1114-101&​o=|FS43]] ​ |  533-558 nm  |  570 nm  |  570-640 nm  | 
-  * Clean up immersion objectives. + 3  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ |  G 365 nm  |  395 nm  |  420-470 nm  |
-  * **Make sure that there really is another user going to use the microscope.** +
-Else: +
-  * Turn off the lasers, wait 5 min for them to cooldown. +
-  * Exit the **ZEN 2009** software and shut down the computer.  +
-  * Clean up immersion objectives. +
-  * Turn off the metal halide lamp. +
-  ​* Turn off the microscope+
-  ​* Turn off the two main switches**SYSTEM/PC** and **COMPONENTS**+
  
-===== If you want to use the UV laser ablation system: ​=====+===== Microscope Turn On Procedure ​===== 
 +  * Turn on the ''​MAIN SWITCH''​ 
 +{{zeiss_lsm_880_1.jpg?​100}} 
 +  * Turn on the ''​SYSTEMS/​PC''​ switch 
 +  * Turn on the computer 
 +  * Login in to Windows (Bioimaging User) 
 +  * Turn on the ''​COMPONENTS''​ switch 
 +  * Start the **ZEN Black** software
  
-  ​Please contact ​the [[about|Bioimaging Facility]] (Ext47316). The ablation system requires specific training even for users that are already trained ​on the LSM 7 Live itself.+===== Microscope Turn Off Procedure ===== 
 +If there is another user for this microscope in the __next hour__: 
 +  ​Exit the ZEN software, leave the lasers on 
 +  * Log off the computer 
 +  * Clean up immersion objectives 
 +Else: 
 +  * Turn off the lasers ​on **ZEN** 
 +  * Clean up immersion objectives 
 +  * Exit the ZEN software 
 +  * Shutdown the computer 
 +  * Turn off the two switches ''​SYSTEMS/​PC''​ and ''​COMPONENTS''​ 
 +  * **Wait 5 minfor Ar laser to cool down** 
 +  * Turn off the ''​MAIN SWITCH''​
  
 ---- ----
- +[[resources|Back to the Equipment ​page]]
-[[resources|Back to the Resources ​page]]+
zeiss_lsm_880.txt · Last modified: 2024/01/28 11:47 by bioimaging