User Tools

Site Tools


zeiss_lsm_880

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
Next revision Both sides next revision
zeiss_lsm_880 [2016/03/29 17:18]
bioimaging created
zeiss_lsm_880 [2020/02/27 15:35]
bioimaging
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_name.jpg">+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_name_new.png">
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki.jpg" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_new.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_new.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_map.jpg">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif" width=15>​ 47217) <​br> ​+<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_map_new.png">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png" width=15>​ 47217) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​
-<​b>​Model</​b>: ​<a href="​http://​www.zeiss.com/​microscopy/​en_de/​products/​confocal-microscopes/​lsm-880-with-airyscan-.html"​ target="​_blank">​LSM 880 with Airyscan</​a><​br>​+<​b>​Model</​b>:​ LSM 880 with Airyscan<​br>​ 
 +<​b>​Nickname</b>: "​880"​<br>
 <​b>​Software</​b>:​ ZEN 2.1 (black) <br> <​b>​Software</​b>:​ ZEN 2.1 (black) <br>
 <​b>​Year</​b>:​ 2016 <br> <​b>​Year</​b>:​ 2016 <br>
Line 14: Line 15:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=ZEISS5LIV&​rid=12"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss LSM 880 Booking</​a>​+&nbsp <​br>​ 
 +&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​128"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss LSM 880 Booking</​a>​
  <​br> ​  <​br> ​
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_7_live_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss LSM 7 Live Quality Control</​a>​ +&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss LSM 880 Quality Control</​a>​
- <​br>​ +
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_7_live_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss LSM 7 Live Usage Statistics</​a>​ +
-&nbsp </​br>​ +
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_7_live_repair"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=repair-icon.gif"​ width=16>​ Zeiss LSM 7 Live Repair History</a>+
  <​br>​  <​br>​
-&rarr; <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?media=manual_lsm_5_live.pdf"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=adobe_pdf_icon.png">​ Zeiss LSM 5 Live Operating Manual</​a>​ +&rarr; <a href="/​facility/​bioimaging/​doku.php?id=zeiss_lsm_880_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss LSM 880 Usage Statistics</​a>​ 
-&​nbsp ​</p>+ </​p>​
 </td> </td>
 </tr> </tr>
Line 31: Line 29:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-The Zeiss LSM 7 Live //​confocal ​line-scanning microscope// ​is a fast imaging system ​able to analyze ​high-speed processes with a time resolution of just a few microseconds. It is an upright ​microscope equipped with water dipping objectives specially suited ​for live samples in aqueous media. The scanning unit uses a laser beam with a rectangular cross-section to [[http://​www.nature.com/nmeth/journal/v3/n11/thumbs/nmeth971-F2.jpg|illuminate a whole line in the sample]], instead ​of a single point. This makes image acquisition ​by its array CCD detectors faster than conventional PMT light detection but it also lowers ​the Z-resolution ​due to the usage of slits instead ​of conventional ​pinholesNote that the system ​is equipped with two lasers (488 and 561 nm) but dual color imaging is not advised since there are no bandpass filters in the system (channel crosstalk is likely to occur). A UV laser controlled by galvanometric mirrors is available for precise ablation in user-defined regions of interestThe spatial resolution of this system ​is not as high as //​point-scanning confocal ​system// such as the [[zeiss_lsm_880|Zeiss ​LSM 880]] or [[zeiss_lsm_710|Zeiss LSM 710]] but it is much faster than these two systems, achieving scanning speeds which may be even higher than the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk if the acquisition is performed only in a few lines. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]].+{{  :​airyscan_beampath.png?​400}} ​The Zeiss LSM 880 with Airyscan is a //​confocal ​point-scanning microscope//​ able to generate ​high-resolution ​three-dimensional images ​of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted ​microscope ​especially suitable for live cell imaging and photobleaching experiments, ​equipped with a large size incubator ​for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. The stage is motorized and furthermore equipped ​with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions. Its [[http://​www.zeiss.com/content/dam/Microscopy/Products/laser-scan/LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan]] 32 channel area detector is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (140 nm laterally and 400 nm axially, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=ln6VUmLzLLc|Fast Mode]], which enables parallel excitation and detection ​of four image pixels. The result is a speed improvement ​by a factor of four, while maintaining ​the sensitivity of Airyscan and 1.5x resolution ​improvement. Its scanning unit further includes two PMT detectors (one of them cooled) as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional ​PMT)It is equipped with lasers ​from violet to far red (405, 458, 488, 514, 561, 594 and 633 nm excitation wavelengths).  
 +{{::​fast_airyscan.png?​420 ​ }}With ​this system ​you can perform optical sectioning of fluorescent samples which are too thick for widefield ​system such as the [[zeiss_cell_observer|Zeiss ​Cell Observer]] or the [[zeiss_axiovert_200m|Zeiss Axiovert 200M]]. Image resolution with Airyscan is higher than the [[zeiss_lsm_710|Zeiss LSM 710]] and detection sensitivity ​is also higher than the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]].
  
-{{info.gif?|}} **If you are going to use the 561 nm laser please write '​561' ​in the Event Field name**+{{:info.png?25|}} Click [[https://​imm.medicina.ulisboa.pt/​facility/​bioimaging/​lib/​exe/​fetch.php?​cache=&​media=airyscan.jpg|here]] to see the system beam path in higher detail 
 + 
 +{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. 
 + 
 +===== Booking Rules ===== 
 +The Zeiss LSM 880 booking is divided in three daily slots: 
 +|  9:00 to 13:00  |  13:00 to 17:00  |  17:00 to 21:00  | 
 + 
 +  - A **user** can book at maximum **2 sessions per week** 
 +  - Each **session must fit inside one of the three daily slots** (i.e. a session booked from 11:00 to 14:00 counts as 2 sessions) 
 +  - The above rules do not apply for **weekends** and for work days **before 9:00** and **after 21:00** 
 +  - The above rules do not apply for sessions booked on the very same day or **24 hours ahead** 
 +  - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**. 
 +  - Users must indicate which lasers they are going to use in the booking Description field 
 +  - Users must indicate if they will use the incubator ​in the booking Description field (write down 37C INCUBATOR)
  
 ===== System components ===== ===== System components =====
Line 39: Line 52:
 ==== LASERs ==== ==== LASERs ====
 ^  Laser Unit  ^  Wavelength ​ ^  Maximum Power  ^  Current Status ​ ^ ^  Laser Unit  ^  Wavelength ​ ^  Maximum Power  ^  Current Status ​ ^
-|  ​Sapphire 488-100  ​| ​ 488 nm  |  ​100 mW  |  ok  | +|  ​Diode 405-30  ​|  ​405 nm  |  30 mW  |  ok  | 
-|  DPSS 561-40  ​| ​ 561 nm  |  ​40 mW  |  ok  |+|  Argon  |  458, 488 and 514 nm  |  ​25 mW  |  ok  | 
 +|  DPSS 561-20  ​| ​ 561 nm  |  ​20 mW  |  ok  | 
 +|  HeNe594 ​ |  594 nm  |  2 mW  |  ok  | 
 +|  HeNe633 ​ |  633 nm  |  5 mW  |  ok  |
  
 ==== Objectives ==== ==== Objectives ====
-^  Magnification ​ ^  Model  ^  ​Type  ​^ ​ NA  ^  WD (mm)  ^ +^  Magnification ​  ​^  Model  ^  ​Immersion ​ ​^ ​ NA  ^  WD (mm)  ​^ ​ Reference ​ ^ 
-|  10x  |  ​[[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440039-0000-000|W Achroplan Ph1]]  ​|  ​Water dipping ​ ​| ​ 0.30  |  ​3.1  | +|  10x  |  ​EC Plan-Neofluar ​ ​|  ​Air  ​| ​ 0.30  |  ​5.20  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]]  ​
-|  10x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=2065696c9e13e&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440330-0000-000|Plan-Neofluar]] ​ |  ​Dry  ​|  ​0.30  ​|  ​5. +|  ​20x  ​|  ​Plan-Apochromat ​ ​|  ​Air  |  0.80  ​|  ​0.55  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]]  ​
-|  ​20x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=421452-9900-000|W Plan-Apochromat]] ​ |  ​Water  ​|  ​1.00  ​| ​ 1. +|  ​40x  ​|  ​C-Apochromat Corr  |  Water  ​| ​ 1.20  ​|  ​0.28  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421767-9970-000/​Objective-C-Apochromat-40x-1.20-W-Corr-M27|421767-9970-000]]  ​
-|  ​40x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440090-9901-000|Achroplan]]  |  ​Water dipping ​ ​|  ​0.80  ​|  ​3. +|  ​63x  ​|  ​Plan-Apochromat DIC  ​|  ​Oil  |  1.40  ​|  ​0.19  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ |
-|  ​40x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar Ph3]]  |  Oil  |  ​1.30  ​ ​0.20 ​ |+
  
 +
 +**Upon request:**
 +
 +^  Magnification ​  ​^ ​ Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
 +|  25x  |  LCI Plan-Neofluar Corr DIC  |  Oil/​Glyc/​W ​ |  0.80  |  0.21  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420852-9973-000/​Objective-LCI-Plan-Neofluar-25x-0.8-Imm-Corr-DIC-M27|420852-9972-000]] ​ |
 +|  40x  |  Plan-Apochromat Corr  |  Dry  |  0.95  |  0.25  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/​Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]] ​ |
 +|  100x  |  α Plan-Apochromat DIC  |  Oil  |  1.46  |  0.11  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420792-9800-000/​Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27|420792-9800-000]] ​ |
 ==== Filtersets (Ocular) ==== ==== Filtersets (Ocular) ====
  
 ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^ ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^
-|  ​ ​| ​ Green  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488010-9901-000&​o=|FS10]]  |  450-490 nm  |  ​515-565 nm  | +|  ​ ​| ​ Green  |  [[https://​www.micro-shop.zeiss.com/?​s=7139069fdc79c&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489038-9901-000&​o=|FS38HE]]  |  450-490 nm  |  ​500-550 nm  | 
-|  ​ ​| ​ Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488015-0000-000&o=|FS15]]  |  ​540-552 nm  |  ​> 590 nm  | +|  ​ ​| ​ Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1114-101&o=|FS43]]  |  ​533-558 nm  |  ​570-640 ​nm  | 
-|  ​ ​| ​ Blue (for ablation*) ​ ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ |  ​none  ​| ​ 420-470 nm  | +|  ​ ​| ​ Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ |  ​G 365 nm  ​| ​ 420-470 nm  |
-* Excitation filter has been removed+
  
-==== Filter and Dichroic sets ==== +===== Microscope Turn On Procedure ===== 
- {{zeiss5livefilters0.jpg?​100}}  ​ {{zeiss5livefilters1.jpg?100}}  | +  ​* Turn on the ''​MAIN SWITCH''​ 
-|  Main configuration ​ |  Emission filters ​ |+  * Turn on the two switches: ''​SYSTEMS/​PC''​ and ''​COMPONENTS''​ 
 +{{zeiss_lsm_880_1.jpg?100}} 
 +  * Turn on the computer 
 +  * Login in to Windows (Bioimaging User) 
 +  * Check that the computer is connected to an ''​Unidentified network''​ (click on the network icon in the taskbar) 
 +{{::​network_icon.png?200}} 
 +  ​* Start the **ZEN** software
  
-===== Microscope Turn On Procedures ===== +===== Microscope Turn Off Procedure ​===== 
- +If there is another user for this microscope in the __next hour__
-==== Normal Operation ==== +  * Exit the ZEN software, leave the lasers on 
- +  * Log off the computer 
-  * The system must be turned on **30 min** before usage. +  * Clean up immersion objectives
-    * To start it turn on the two main switches: ''​SYSTEM/​PC''​ and ''​COMPONENTS''​ +
-{{7live_switches.jpg?​100|}} +
-  * Login to the computer, wait for the network icon to change to ''​connected''​ state +
-  * Start the **ZEN 2009** software. +
-**After the 30 min:** +
-  * Turn on the metal halide lamp (white box to the left of the microscope). +
-{{7live_excite.jpg?​100|}} +
-  * You may now start using the system. +
- +
-==== Live Imaging / Time Lapse Operation ==== +
- +
-  * The system must be turned on **2 hours** before usage (in order to properly warm up scanning mirrors). +
-    * To start it turn on the two main switches: **SYSTEM/​PC** and **COMPONENTS** +
-  * Login to the computer, wait for the network icon to change to ''​connected''​ state +
-  * Start the **ZEN 2009** software. +
-**After the 2 hours:** +
-  * Turn on the metal halide lamp (white box to the left of the microscope). +
-  * You may now start using the system. +
- +
-===== Microscope Turn Off procedures ​===== +
-If there'​s ​another user for this microscope in the next two hours+
-  * Exit the **ZEN 2009** ​software, leave the lasers on and log off the computer +
-  * Clean up immersion objectives+
-  * **Make sure that there really is another user going to use the microscope.**+
 Else: Else:
-  * Turn off the lasers, wait 5 min for them to cooldown. +  * Turn off the lasers ​on **ZEN** 
-  * Exit the **ZEN 2009** software and shut down the computer. ​ +  * Clean up immersion objectives 
-  * Clean up immersion objectives. +  * Exit the ZEN software 
-  * Turn off the metal halide lamp. +  * Shutdown ​the computer 
-  * Turn off the microscope. +  * Turn off the two switches ​''​SYSTEMS/PC''​ and ''​COMPONENTS''​ 
-  * Turn off the two main switches: **SYSTEM/PC** and **COMPONENTS** +  ​* **Wait 5 min. for Ar laser to cool down** 
- +  * Turn off the ''​MAIN SWITCH''​
-===== If you want to use the UV laser ablation system: ===== +
- +
-  * Please contact ​the [[about|Bioimaging Facility]] (Ext: 47316). The ablation system requires specific training even for users that are already trained on the LSM 7 Live itself.+
  
 ---- ----
- 
 [[resources|Back to the Resources page]] [[resources|Back to the Resources page]]
zeiss_lsm_880.txt · Last modified: 2024/01/28 11:47 by bioimaging