User Tools

Site Tools


usage_policy

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
usage_policy [2020/03/26 18:26]
flowcytometry
usage_policy [2021/11/18 22:25]
flowcytometry
Line 1: Line 1:
-<​html><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=usage_rules.png"><​BR><​BR></​html>​+<​html><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=usage_rules_v2_1.png"><​BR><​BR></​html>​
  
 Please download the detailed [[https://​imm.medicina.ulisboa.pt/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=sop.ucf.004_-_ucf_imm_user_guidelines.pdf|User Guidelines]] for your own reference. Please download the detailed [[https://​imm.medicina.ulisboa.pt/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=sop.ucf.004_-_ucf_imm_user_guidelines.pdf|User Guidelines]] for your own reference.
Line 15: Line 15:
   - Users must **switch off the system** if they are the **last user booked** or if the analyzer **will not be used for at least 3h**   - Users must **switch off the system** if they are the **last user booked** or if the analyzer **will not be used for at least 3h**
   - Users must always export their data and delete it from the FACSDiva database regularly   - Users must always export their data and delete it from the FACSDiva database regularly
-  - Users must **always clean the machines** following the cleaning protocol and **record the cleaning steps** in FACSDiva+  - Users must **always clean the machines** ​after acquisition ​following the cleaning protocol and **record the cleaning steps** in FACSDiva 
 +  - Users must perform an additional cleaning before acquisition if they are the **first user of the day** 
   - Users must **refill the sheath tank** with PBS+Azide at the end of the booked session.   - Users must **refill the sheath tank** with PBS+Azide at the end of the booked session.
   - If during acquisition,​ the **waste container gets full**, a high pitch sound will go off. Users should **disconnect the black sensor** (the noise will stop), put the cytometer in **Standby**,​ and **disconnect   - If during acquisition,​ the **waste container gets full**, a high pitch sound will go off. Users should **disconnect the black sensor** (the noise will stop), put the cytometer in **Standby**,​ and **disconnect
-the orange connector.** ​Close the container with the red cap that is on top of it and replace the container with a new one.+the orange connector.** ​The container ​must be replaced ​with a new one.
  
 {{warning.jpg?​20|}} Users will be **billed according to the actual starting time or booked starting time (whichever occurs first) and the actual ending time or booked ending time (whichever occurs last)** {{warning.jpg?​20|}} Users will be **billed according to the actual starting time or booked starting time (whichever occurs first) and the actual ending time or booked ending time (whichever occurs last)**
Line 32: Line 33:
   - If you need to book a sorter outside the regular working hours, please contact us beforehand to check for staff availability. ​   - If you need to book a sorter outside the regular working hours, please contact us beforehand to check for staff availability. ​
   - Users must **include time in their booking for new settings, purity checks and cleaning** (minimum 30 min)   - Users must **include time in their booking for new settings, purity checks and cleaning** (minimum 30 min)
-  - Users must mention in the booking comments which nozzle (70 μm, 85 μm or 100 μm) and collection ​tubes (1.5 mL tubes, 5 mL FACS tubes or 15 mL Falcon tubes) they will be using+  - Users must mention in the booking comments ​the Biosafety Level (BSL) of their samples, ​which nozzle (70 μm, 85 μm or 100 μm) and which collection ​devices ​(plates, ​1.5 mL tubes, 5 mL FACS tubes or 15 mL Falcon tubes) they will be using
   - Users must not book on behalf of others   - Users must not book on behalf of others
   - Users **can only cancel bookings 7 days in advance**   - Users **can only cancel bookings 7 days in advance**
Line 40: Line 41:
 \\ \\
  
-{{warning.jpg?​20|}} ** NO SHOWS** ​(or cancellation in the booked day) - **the charge corresponds to the running cost of the system** +{{warning.jpg?​20|}} ** NO SHOWS** ​ - **the charge corresponds to the running cost of the system**
- +
-==== Sample Preparation ==== +
- +
-Please check **[[prepare_samples|How to prepare samples for Flow Cytometry]]**.+
  
 ===== Abuse Report ===== ===== Abuse Report =====
usage_policy.txt · Last modified: 2024/02/28 22:35 by flowcytometry