User Tools

Site Tools


bd_lsr_fortessa_1

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
bd_lsr_fortessa_1 [2023/03/30 16:36]
flowcytometry [Additional Information]
bd_lsr_fortessa_1 [2023/11/02 17:11]
flowcytometry
Line 8: Line 8:
 <​b>​Location</​b>:​ <a href="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=flow_cytometry_map.jpg">​Room P2-A-49</​a>​ (<img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=telephone_icon.gif"​ width=15>​ 47224) <​br> ​ <​b>​Location</​b>:​ <a href="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=flow_cytometry_map.jpg">​Room P2-A-49</​a>​ (<img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=telephone_icon.gif"​ width=15>​ 47224) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.bdbiosciences.com/​eu/​home"​ target="​_blank">​BD Biosciences</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.bdbiosciences.com/​eu/​home"​ target="​_blank">​BD Biosciences</​a><​br>​
-<​b>​Model</​b>:​ <a href="http://​www.bdbiosciences.com/​us/​instruments/​research/​cell-analyzers/​bd-lsrfortessa/​m/​751752/​overview" target="​_blank">​LSRFortessa</​a><​br>​+<​b>​Model</​b>:​ <a href="https://​www.bdbiosciences.com/​en-us/products/​instruments/​flow-cytometers/research-cell-analyzers/​bd-lsrfortessa"​ target="​_blank">​LSRFortessa</​a><​br>​
 <​b>​Nickname</​b>:​ "​Fortessa 1"<​br>​ <​b>​Nickname</​b>:​ "​Fortessa 1"<​br>​
 <​b>​Software</​b>:​ FACSDiva 6.2<​br>​ <​b>​Software</​b>:​ FACSDiva 6.2<​br>​
Line 28: Line 28:
 ===== System overview ===== ===== System overview =====
  
-{{  :cell_analyzers.png?​0x300|}} The BD LSRFortessa 1 //cell analyzer// is a benchtop digital flow cytometer equipped with a fixed-alignment flow cell that is gel-coupled to the collection optics. It has three spatially separated lasers - 405 nm, 488 nm and 640 nm. Its primary function is to characterize complex populations of cells. Individual cells pass single file through a stream, which is interrogated by the three lasers with the emitted light being detected by photomultiplier (PMT) tubes. The system electronics calculates the time it takes a single cell to pass through each laser intercept and assigns the signal of each PMT to the appropriate cell. Besides fluorescence,​ the physical properties of the cell are also analyzed with side scatter (SSC), which reflects the internal complexity of a cell and forward scatter (FSC), which is roughly proportional to cell size. The sample flow rate can be set to low, medium and high values, which correspond approximately to 12, 35 and 60 μl/minute, respectively. ​+{{  :flow_cell_sit_sample.png?​0x300|}} The BD LSRFortessa 1 //cell analyzer// is a benchtop digital flow cytometer equipped with a fixed-alignment flow cell that is gel-coupled to the collection optics. It has three spatially separated lasers - 405 nm, 488 nm and 640 nm. Its primary function is to characterize complex populations of cells. Individual cells pass single file through a stream, which is interrogated by the three lasers with the emitted light being detected by photomultiplier (PMT) tubes. The system electronics calculates the time it takes a single cell to pass through each laser intercept and assigns the signal of each PMT to the appropriate cell. Besides fluorescence,​ the physical properties of the cell are also analyzed with side scatter (SSC), which reflects the internal complexity of a cell and forward scatter (FSC), which is roughly proportional to cell size. The sample flow rate can be set to low, medium and high values, which correspond approximately to 12, 35 and 60 μl/minute, respectively. ​
  
   * Three lasers - violet (405 nm), blue (488 nm) and red (640 nm)   * Three lasers - violet (405 nm), blue (488 nm) and red (640 nm)
bd_lsr_fortessa_1.txt · Last modified: 2023/11/07 12:55 by flowcytometry