User Tools

Site Tools


bd_facsaria_iii

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
bd_facsaria_iii [2019/08/07 16:52]
flowcytometry
bd_facsaria_iii [2024/03/23 21:56] (current)
flowcytometry
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=bd_facsaria_iii_name.jpg">+<img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=aria_iii_name_wiki.png">
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=aria_iii_wiki.jpg"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=aria_iii_wiki.jpg" width=300></​a>​+<a href="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=aria_iii_wiki.png"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=aria_iii_wiki_new.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
 <​b>​Location</​b>:​ <a href="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=flow_cytometry_map.jpg">​Room P2-A-49</​a>​ (<img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=telephone_icon.gif"​ width=15>​ 47224) <​br> ​ <​b>​Location</​b>:​ <a href="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=flow_cytometry_map.jpg">​Room P2-A-49</​a>​ (<img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=telephone_icon.gif"​ width=15>​ 47224) <​br> ​
Line 16: Line 16:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&nbsp <​br>​ +&rarr; <a href="​https://​my.agendoscience.com/calendar/?​id=NDVjYWxlbmRhcnM="​ target="​_blank"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=booking.png"> ​ BD FACSAria III Booking</​a>​
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/intranet/booking/8"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=date.png"> ​ BD FACSAria III Booking</​a>​+
  <​br> ​  <​br> ​
-&rarr; <a href="/​facility/​flowcytometry/​doku.php?​id=bd_facsaria_iii_usage"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ BD FACSAria III Usage Statistics</​a>​+&rarr; <a href="/​facility/​flowcytometry/​doku.php?​id=bd_facsaria_iii_usage"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=statistics.png"> ​ BD FACSAria III Usage Statistics</​a>​ 
 +<br>  
 +&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=bd-facsaria-iii-cell-sorter-brochure.pdf"​ target="​_blank"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=brochure.png"> ​ BD FACSAria III brochure</a>
 &nbsp </p> &nbsp </p>
 </td> </td>
Line 25: Line 26:
 </​table>​ </​table>​
 </​html>​ </​html>​
-{{:​info.gif|}} **Next Scheduled ​Maintenance**: October 29, 2019+{{:​info.gif|}} **Next Scheduled ​Maintenances**: 1 April and 23 September
  
 {{:​info.gif|}} [[aria_iii_contamination|Pseudomonas contamination timeline]] {{:​info.gif|}} [[aria_iii_contamination|Pseudomonas contamination timeline]]
Line 31: Line 32:
 ===== System overview ===== ===== System overview =====
  
-{{  :​cell_sorting.png?​0x300|}} The BD FACSAria III //cell sorter// is a high speed benchtop digital flow cytometer equipped with a sensitive, fixed-alignment cuvette flow cell. It has three spatially separated lasers - 488 nm, 561 nm and 633 nm. Its primary function is to analyze complex populations of cells and yield pure populations of cells meeting defined criteria. The sorter can purify samples that are simply positive and negative for a single fluorophore or as complex as multi-color samples with complex gating strategies. Sorting can be performed into two or four tubes with speeds up to 25,000 events/​second. The system sorts by incorporating cells from the sample tube into a stream of sterile PBS. The stream is interrogated by the lasers at the flow cell and the system electronics keeps track of each cell as they pass through the laser and determines specific cells that meet the sort criteria. A transducer vibrates the stream and induces droplet formation, with cells in the stream being incorporated into the droplets. If a cell meets the sorting criteria and is in the last drop before the break off, the instrument will charge that drop. The charged droplet is then deflected into the proper collection tube by the charge plates. Different cell types can be sorted with the use of 70 μm, 85 μm and 100 μm nozzles. **The instrument is housed in a Baker BioProtect-IV bio-safety cabinet** and is able therefore to sort human samples. If you need a violet (405 nm) laser, check the [[bd_facsaria_iiu|BD FACSAria IIu]] instead.+{{  :​cell_sorting.png?​0x300|}} The BD FACSAria III //cell sorter// is a high speed benchtop digital flow cytometer equipped with a sensitive, fixed-alignment cuvette flow cell. It has four spatially separated lasers - 405 nm, 488 nm, 561 nm and 633 nm. Its primary function is to analyze complex populations of cells and yield pure populations of cells meeting defined criteria. The sorter can purify samples that are simply positive and negative for a single fluorophore or as complex as multi-color samples with complex gating strategies. ​
  
-  * Three lasers with blue (488 nm), yellow-green (561 nm) and red (633 nm) +Sorting can be performed into two or four tubes with speeds up to 25,000 events/​second. The system sorts by incorporating cells from the sample tube into a stream of sterile PBS. The stream is interrogated by the lasers ​at the flow cell and the system electronics keeps track of each cell as they pass through the laser and determines specific cells that meet the sort criteria. A transducer vibrates the stream and induces droplet formation, ​with cells in the stream being incorporated into the droplets. If a cell meets the sorting criteria and is in the last drop before the break off, the instrument will charge that drop. The charged droplet is then deflected into the proper collection tube by the charge plates. Different cell types can be sorted with the use of 70 μm, 85 μm and 100 μm nozzles. 
-  * Multicolor analysis of up to 10 parameters + 
-  * 70 μm, 85 μm and 100 μm nozzles available+  * Four lasers - violet (405 nm), blue (488 nm), yellow-green (561 nm) and red (633 nm) 
 +  * Multicolor analysis of up to 16 parameters 
 +  * 70 μm, 85 μm100 μm and 130 μm nozzles available
   * Up to 4-way sorting into 1.5 ml or 4 ml tubes and 2-way sorting into 15 ml tubes   * Up to 4-way sorting into 1.5 ml or 4 ml tubes and 2-way sorting into 15 ml tubes
 +  * Sorting for 6-, 12-, 24-, 96-, 384-well and PCR plates
 +
 +**If you need to sort potentially hazardous samples (e.g human samples and other BSL-2 level samples) you need to sort in the [[bd_facsaria_fusion|BD FACSAria Fusion]] or [[bd_facsymphony_s6_se|BD FACSymphony S6 SE]] equiped with a Class II Type A2 biosafety cabinet to reduce the risk of operator exposure.**  ​
 +
 +\\
 +**If you need high parameter cell sorting, check the [[bd_facsymphony_s6_se|BD FACSymphony S6 SE]].**
  
 ===== Configuration ===== ===== Configuration =====
  
-{{:bd_facsaria_iii_configuration_wiki.png?800|}}+{{:bd_facsaria_iii_configuration_new_.png?900|}} 
  
 ===== Fluorophores Compatibility ===== ===== Fluorophores Compatibility =====
  
-{{:bd_facsaria_iii_fluorophores_wiki.png?800|}}+{{:facsaria_iii_fluorochrome_compatibility.png?900|}} 
 +\\ 
 +{{:​aria_additional_filters.png?​300|}} 
 +\\
 \\ \\
 +{{::​bd_lsrfortessa_x-20_405.png?​700|}}
 \\ \\
-{{::​bd_facsaria_iii_488.png?​800|}}+{{::​bd_facsaria_iii_488.png?​700|}}
 \\ \\
-{{::​bd_facsaria_iii_561.png?​800|}}+{{::​bd_facsaria_iii_561.png?​700|}}
 \\ \\
-{{::​bd_facsaria_iii_633.png?​800|}}+{{::​bd_facsaria_iii_633.png?​700|}}
  
-===== Additional Information ​=====+===== Useful Links when Preparing your Experiment ​=====
  
-  ​* **[[prepare_samples|How to prepare samples for Flow Cytometry]]** +  * [[prepare_samples|{{how_to_prepare_samples_for_flow_cytometry.png}}]] 
-  * **[[sorting_faq|What should I expect when sorting?]]**+  ​<​html><​a href="​http://​www.bdbiosciences.com/​en-us/​applications/​research-applications/​multicolor-flow-cytometry/​product-selection-tools/​spectrum-viewer"​ target="​_blank"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=bd_spectrum_viewer.png"​ WIDTH=300></​a></​html>​ 
 +  * <​html><​a href="​http://​www.bdbiosciences.com/​en-us/​applications/​research-applications/​multicolor-flow-cytometry/​product-selection-tools/​spectrum-viewer"​ target="​_blank"><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?media=bd_research_cloud.png"​ WIDTH=300></​a></​html>​
  
 ===== Booking Rules ===== ===== Booking Rules =====
  
-The system is available for booking from 10am to 10pm from Monday to Friday. ​+The system is available for booking from 10am to 6pm from Monday to Friday. ​
  
 The cell sorting service is provided by a dedicated technician upon reservation on the online booking system. ​ The cell sorting service is provided by a dedicated technician upon reservation on the online booking system. ​
Line 69: Line 84:
 ---- ----
  
-[[resources|Back to the Resources ​page]]+[[resources|Back to the Equipment ​page]]
bd_facsaria_iii.1565189538.txt.gz · Last modified: 2019/08/07 16:52 by flowcytometry