prepare_samples
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| prepare_samples [2024/01/17 17:33] – flowcytometry | prepare_samples [2026/11/16 17:25] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 4: | Line 4: | ||
| Talk to us about your experiment! If you want to use Flow Cytometry, we can help you design your new experiment. Get in contact with us and we will guide you through the Flow Cytometry Facility, and suggest the best systems for your project. Finally, we will book a training session with you and plan a trial run with your samples. | Talk to us about your experiment! If you want to use Flow Cytometry, we can help you design your new experiment. Get in contact with us and we will guide you through the Flow Cytometry Facility, and suggest the best systems for your project. Finally, we will book a training session with you and plan a trial run with your samples. | ||
| + | |||
| + | Here you can find summed up information on the essentials of handling your samples. | ||
| + | \\ | ||
| + | For more info check our **full document** on < | ||
| Line 24: | Line 28: | ||
| ***Sorting of cells by flow cytometry: | ***Sorting of cells by flow cytometry: | ||
| - | Many staining protocols include a fixation and/or permeabilization step. However, if yours doesn’t and you need to fix your BSL-2 cells for analysis, we suggest **[[https:// | + | Many staining protocols include a fixation and/or permeabilization step. However, if yours doesn’t and you need to fix your BSL-2 cells for analysis, we suggest **{{: |
| {{ biosafety_ucf.png? | {{ biosafety_ucf.png? | ||
| Line 30: | Line 34: | ||
| **__Exclude your dead cells__** | **__Exclude your dead cells__** | ||
| - | Even though you keep your cells as happy as possible, some cells can die while handling and performing staining protocols. \\ Dead cells can affect the analysis by compromising the integrity of the data by non-specifically binding antibodies. That’s why most experiments benefit from adding a viability dye, to exclude dead cells from analysis and sorting. Also this viability staining can help you evaluate and compare the cell apoptosis and necrotic stages between cell conditions.\\ There are Fixable and Non-Fixable viability dyes. You can choose the right one for your assay depending on the purpose of your analysis and the post-staining protocol that will be performed. | + | Even though you keep your cells as happy as possible, some cells can die while handling and performing staining protocols. \\ Dead cells can affect the analysis by compromising the integrity of the data by non-specifically binding antibodies. That’s why most experiments benefit from adding a viability dye, to exclude dead cells from analysis and sorting. Also this viability staining can help you evaluate and compare the cell apoptosis and necrotic stages between cell conditions.\\ There are Fixable and Non-Fixable viability dyes. You can choose the right one for your assay depending on the purpose of your analysis and the post-staining protocol that will be performed. . |
| **__Perform the desired cell staining__** | **__Perform the desired cell staining__** | ||
| Line 40: | Line 44: | ||
| * **DNA staining** can be used for cell cycle analysis. | * **DNA staining** can be used for cell cycle analysis. | ||
| - | While staining of surface markers can be performed in live/ | + | While staining of surface markers can be performed in live/ |
| **__Choose the right tubes__** | **__Choose the right tubes__** | ||
| Line 49: | Line 53: | ||
| ===== Which controls do you need? ===== | ===== Which controls do you need? ===== | ||
| - | Every experiment needs controls.\\ Bring **unlabeled cells** as a negative control. This sample will help you selecting the right cytometer settings for your acquisition. In addition, it will assist you in the analysis, while doing the gating strategy.\\ If you are using more than one color, you need **single-color compensation controls**. These will work to evaluate the spectral overlap between all the colors you have. If there is spillover between some colors, compensation will be performed.\\ For more detailed information about single colors preparation, | + | Every experiment needs controls.\\ Bring **unlabeled cells** as a negative control. This sample will help you selecting the right cytometer settings for your acquisition. In addition, it will assist you in the analysis, while doing the gating strategy.\\ If you are using more than one color, you need **single-color compensation controls**. These will work to evaluate the spectral overlap between all the colors you have. If there is spillover between some colors, compensation will be performed.\\ For more detailed information about single colors preparation, |
| ===== For sorting, which collection devices can you use? ===== | ===== For sorting, which collection devices can you use? ===== | ||
| Line 96: | Line 100: | ||
| | Extra media/PBS for diluting samples | | Extra media/PBS for diluting samples | ||
| - | + | -------- | |
| - | [[newuser|Back to New User]] | + | [[newuser|Back to Training - Access to our resources]] |
| + | \\ | ||
| + | [[about|Back to Our Platform]] | ||
| + | \\ | ||
| + | [[start|Back to Flow Cytometry Wiki]] | ||
prepare_samples.1705512812.txt.gz · Last modified: by flowcytometry