Line 6: Line 6:
 <img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=fortessa_sorp_wiki.png"​WIDTH=300>​ <img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=fortessa_sorp_wiki.png"​WIDTH=300>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ Oeiras Site, Room 0B01, Bartolomeu Dias Wing <​br> ​+<​b>​Location</​b>:​ Oeiras Site, Room 0B01, Bartolomeu Dias Wing, <​br>​(<​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=telephone_icon.gif"​ width=15>​ 4625)<​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.bdbiosciences.com/​eu/​home"​ target="​_blank">​BD Biosciences</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.bdbiosciences.com/​eu/​home"​ target="​_blank">​BD Biosciences</​a><​br>​
 <​b>​Model</​b>:​ <a href="​https://​www.bdbiosciences.com/​en-us/​products/​instruments/​flow-cytometers/​research-cell-analyzers/​bd-lsrfortessa"​ target="​_blank">​LSRFortessa</​a><​br>​ <​b>​Model</​b>:​ <a href="​https://​www.bdbiosciences.com/​en-us/​products/​instruments/​flow-cytometers/​research-cell-analyzers/​bd-lsrfortessa"​ target="​_blank">​LSRFortessa</​a><​br>​
 <​b>​Nickname</​b>:​ "​Fortessa SORP"<​br>​ <​b>​Nickname</​b>:​ "​Fortessa SORP"<​br>​
-<​b>​Software</​b>:​ FACSDiva <br>+<​b>​Software</​b>: ​BD FACSDiva ​9.0 <br>
 <​b>​Year</​b>:​ 2010 <br> <​b>​Year</​b>:​ 2010 <br>
-<​b>​SN</​b>:​ <br>+<​b>​SN</​b>: ​H647900900001<br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
Line 24: Line 24:
 </​table>​ </​table>​
 </​html>​ </​html>​
-{{:​info.gif|}} **Next Scheduled Maintenances**: ​+{{:​info.gif|}} **Next Scheduled Maintenances**: ​14 may and 19 November
  
 ===== System overview ===== ===== System overview =====
  
 {{  :​flow_cell_sit_sample.png?​0x300|}} The BD LSRFortessa //cell analyzer// is a benchtop digital flow cytometer equipped with a fixed-alignment flow cell that is gel-coupled to the collection optics. It has three spatially separated lasers - 442 nm, 488 nm and 561 nm. Its primary function is to characterize complex populations of cells. Individual cells pass single file through a stream, which is interrogated by the three lasers with the emitted light being detected by photomultiplier (PMT) tubes. The system electronics calculates the time it takes a single cell to pass through each laser intercept and assigns the signal of each PMT to the appropriate cell. Besides fluorescence,​ the physical properties of the cell are also analyzed with side scatter (SSC), which reflects the internal complexity of a cell and forward scatter (FSC), which is roughly proportional to cell size. The sample flow rate can be set to low, medium and high values, which correspond approximately to 12, 35 and 60 μl/minute, respectively. ​ {{  :​flow_cell_sit_sample.png?​0x300|}} The BD LSRFortessa //cell analyzer// is a benchtop digital flow cytometer equipped with a fixed-alignment flow cell that is gel-coupled to the collection optics. It has three spatially separated lasers - 442 nm, 488 nm and 561 nm. Its primary function is to characterize complex populations of cells. Individual cells pass single file through a stream, which is interrogated by the three lasers with the emitted light being detected by photomultiplier (PMT) tubes. The system electronics calculates the time it takes a single cell to pass through each laser intercept and assigns the signal of each PMT to the appropriate cell. Besides fluorescence,​ the physical properties of the cell are also analyzed with side scatter (SSC), which reflects the internal complexity of a cell and forward scatter (FSC), which is roughly proportional to cell size. The sample flow rate can be set to low, medium and high values, which correspond approximately to 12, 35 and 60 μl/minute, respectively. ​
 +
 +__Although the LSRFortessa SORP has a default configuration,​ it also allows the use of alternative configurations,​ taking advantage of a full set of optical filters and dichroic mirrors.__ This enables the optimization of the equipment to the project'​s requirements. See the default configuration,​ and the available set of filters bellow.
  
 The LSRFortessa is equipped with a **High Throughput Sampler (HTS)**, which allows the automated acquisition of samples from 96 and 384 well plates. ​ The LSRFortessa is equipped with a **High Throughput Sampler (HTS)**, which allows the automated acquisition of samples from 96 and 384 well plates. ​
Line 37: Line 39:
   * Two SSC detectors   * Two SSC detectors
   * Multicolor analysis of up to 10 parameters   * Multicolor analysis of up to 10 parameters
-  * Flexible set of filters and mirrors, allowing the use of alternative configurations+  * Flexible set of optical ​filters and dichroic ​mirrors, allowing the use of alternative configurations
  
 ===== Default Configuration ===== ===== Default Configuration =====
Line 46: Line 48:
  
 <​html><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=fortessa_sorp_fluorochromes.png"​WIDTH=900><​br><​br>​ <​html><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=fortessa_sorp_fluorochromes.png"​WIDTH=900><​br><​br>​
 +</​html>​
 +
 +<​html><​img src="/​facility/​flowcytometry/​lib/​exe/​fetch.php?​media=optical_filters_and_mirrors_fortessa_sorp.png"><​br><​br>​
 </​html>​ </​html>​
  
Line 59: Line 64:
  
 Available 7 days a week, 24 hours a day for trained researchers. ​ Available 7 days a week, 24 hours a day for trained researchers. ​
- 
-Please check the {{ ::​sop.ucf.004_-_ucf_imm_user_guidelines.pdf |User Guidelines}} for detailed information. 
  
 ---- ----
  
 [[resources|Back to the Equipment page]] [[resources|Back to the Equipment page]]
bd_lsr_fortessa_sorp.1724669236.txt.gz · Last modified: 2024/08/26 12:47 by flowcytometry