Previous revision
zeiss_lsm_980-32 [2024/04/01 22:52]
bioimaging
zeiss_lsm_980-32 [2024/04/02 00:20] (current)
bioimaging
Line 29: Line 29:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-{{  :​confocal_pinhole.png?​340}} The Zeiss LSM 980-32 with Airyscan 2 is a [[https://​www.youtube.com/​watch?​v=rTkjQ6Q0p5I|point-scanning confocal microscope]] able to generate high-resolution three-dimensional images of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted microscope especially suitable for live cell imaging and photobleaching experiments,​ equipped with a dark large cage incubator and a stage top incubator for temperature control and CO2 supply ​and with Definite Focus.3 for hardware focus control during long time-lapse acquisitions. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions, using the Tiles Advanced Setup of ZEN blue. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan 2]] with 32 concentrically arranged GaAsP detection elements is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (120 nm laterally and 350 nm axially in SR mode, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=tUiEa7vcggQ|Multiplex Mode]], which enables parallel excitation and detection in 4Y or 8Y modes. The result is a speed improvement ​by a factor ​of 4x/8x, while maintaining ​the sensitivity ​of Airyscan. Its scanning unit further includes a [[https://​imm.medicina.ulisboa.pt/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=32-channel_quasar.png|32-channel GaAsP detector]] for simultaneous spectral imaging and separation of fluorescent labels and two PMT detectors. It is equipped with lasers from violet to far red (405, 488, 561 and 639 nm excitation wavelengths). ​The [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|LSM Plus deconvolution]] mode enhances signal-to-noise ratio by acting as a denoising step post image acquisition,​ allowing for high acquisition speed and low laser power. ​With [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|Airyscan Joint Deconvolution (jDCV)]] the resolution can be improved to 90 nm (XY) and 270 nm (Z).+{{  :​confocal_pinhole.png?​340}} The Zeiss LSM 980-32 with Airyscan 2 is a [[https://​www.youtube.com/​watch?​v=rTkjQ6Q0p5I|point-scanning confocal microscope]] able to generate high-resolution three-dimensional images of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted microscope especially suitable for live cell imaging and photobleaching experiments,​ equipped with a dark large cage incubator and a stage top incubator for temperature control and CO2 supplywith Definite Focus.3 for hardware focus control during long time-lapse acquisitions, and with an [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research/​autoimmersion-module.html|autoimmersion module for water objectives]]. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions, using the Tiles Advanced Setup of ZEN blue. It is equipped with [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​ai-sample-finder.html|AI Sample Finder]] for automated sample placement, focus adjustment and identification of the relevant sample areas. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan 2]] with 32 concentrically arranged GaAsP detection elements is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (120 nm laterally and 350 nm axially in SR mode, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=tUiEa7vcggQ|Multiplex Mode]], which enables parallel excitation and detection in 4Y or 8Y modes (speed improvement of 4x/8x maintaining ​Airyscan ​sensitivity). Its scanning unit further includes a [[https://​imm.medicina.ulisboa.pt/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=32-channel_quasar.png|32-channel GaAsP detector]] for simultaneous ​[[https://​zeiss-campus.magnet.fsu.edu/​articles/​spectralimaging/​introduction.html|spectral imaging and separation of fluorescent labels]] and two PMT detectors. It is equipped with lasers from violet to far red (405, 445, 488, 514, 561, 594 and 639 nm excitation wavelengths). ​Its[[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|LSM Plus deconvolution]] mode enhances signal-to-noise ratio by acting as a denoising step post image acquisition,​ allowing for high acquisition speed and low laser power. ​Using its [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|Airyscan Joint Deconvolution (jDCV)]] ​option, ​the resolution can be improved to 90 nm (XY) and 270 nm (Z). A dedicated workstation is also available for Direct Processing during acquisition.
  
-  * [[https://​www.youtube.com/​watch?​v=zA4xqq-EL9g|ZEISS Webinar: LSM 980 Airyscan 2 Multiplex ​mode]]+  * **Microscope**:​ [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research.html|Zeiss Axio Observer]] 
 +  * **LED Illumination**:​ [[https://​www.zeiss.com/​microscopy/​en/​products/​accessories/​colibri.html|Zeiss Colibri 7]] 
 +  * **Camera (right port)**: [[https://​www.zeiss.com/​microscopy/​en/​products/​cameras/​axiocam-305-mono.html|Axiocam 305m]] 
 +  * **Features** 
 +    * |  [[https://​www.imdik.pan.pl/​images/​Us%C5%82ugi_dokumenty/​Przydatne_informacje/​2d_Definite_Focus_information.pdf|Definite Focus.3]] 
 +    * | [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research/​autoimmersion-module.html|Auto-immersion Module]] 
 +    * | [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​ai-sample-finder.html|AI Sample Finder]] 
 +    * | [[https://​www.zeiss.fr/​content/​dam/​Microscopy/​fr/​download/​note_application_a_ten_color.pdf|Spectral Imaging]] 
 +    * | [[https://​www.youtube.com/​watch?​v=tUiEa7vcggQ|Airyscan 2 Multiplex]] 
 +    * | [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|LSM Plus]] 
 +    * | [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|Joint Deconvolution]]
  
 <​html>​ <​html>​
 <p align="​center"><​iframe width="​420"​ height="​236"​ src="​https://​www.youtube.com/​embed/​Ji_PVld77Gs"​ title="​YouTube video player"​ frameborder="​0"​ allow="​accelerometer;​ autoplay; clipboard-write;​ encrypted-media;​ gyroscope; picture-in-picture"​ allowfullscreen></​iframe></​p>​ <p align="​center"><​iframe width="​420"​ height="​236"​ src="​https://​www.youtube.com/​embed/​Ji_PVld77Gs"​ title="​YouTube video player"​ frameborder="​0"​ allow="​accelerometer;​ autoplay; clipboard-write;​ encrypted-media;​ gyroscope; picture-in-picture"​ allowfullscreen></​iframe></​p>​
 </​html>​ </​html>​
 +
 +  * [[https://​www.youtube.com/​watch?​v=zA4xqq-EL9g|ZEISS Webinar: LSM 980 Airyscan 2 Multiplex mode]]
  
 {{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. {{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
Line 49: Line 61:
 ^  Laser Unit  ^  Wavelength ​ ^  Maximum Power  ^ ^  Laser Unit  ^  Wavelength ​ ^  Maximum Power  ^
 |  405  |  405 nm  |  15 mW  | |  405  |  405 nm  |  15 mW  |
 +|  445  |  445 nm  |  10 mW  |
 |  488  |  488 nm  |  13 mW  | |  488  |  488 nm  |  13 mW  |
 +|  514  |  514 nm  |  13 mW  |
 |  561  |  561 nm  |  13 mW  | |  561  |  561 nm  |  13 mW  |
 +|  594  |  594 nm  |  4 mW  |
 |  639  |  639 nm  |  10 mW  | |  639  |  639 nm  |  10 mW  |
  
 ==== Objectives ==== ==== Objectives ====
 ^  Magnification ​  ​^ ​ Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ ^  Magnification ​  ​^ ​ Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
-|  ​10x  ​| ​ EC Plan-Neofluar ​ ​| ​ Air  |  0.30  ​|  ​5.20  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ |+|  ​5x  ​| ​ EC Plan-NeoFluar ​ ​| ​ Air  |  0.16  ​|  ​13. ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ |
 |  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9903-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9903-000]] ​ | |  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9903-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9903-000]] ​ |
-|  40x  |  LD C-Apochromat Corr  |  Water  |  1.10  ​| ​ 0.62  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421867-9970-000/​Objective-LD-C-Apochromat-40x-1.1-W-Corr-M27|421867-9970-000]]  |+|  40x  |  LD LCI Plan-Apochromat Corr  |  Water  |  1.20  ​| ​ 0.41  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420862-9970-799/​Objective-LD-LCI-Plan-Apochromat-40x-1.2-Imm-Corr-DIC-M27|420862-9970-799]]  |
 |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ | |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ |
  
 ==== LEDs (Ocular) ==== ==== LEDs (Ocular) ====
 ^  Line  ^  Wavelength ​ ^ ^  Line  ^  Wavelength ​ ^
-|  UV  |  ​405 nm  |+|  UV  |  ​385 nm  |
 |  B  |  475 nm  | |  B  |  475 nm  |
 |  G  |  555 nm  | |  G  |  555 nm  |
zeiss_lsm_980-32.1712004740.txt.gz · Last modified: 2024/04/01 22:52 by bioimaging