Line 10: Line 10:
 <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​confocal-microscopes/​lsm-980-with-airyscan-2.html">​LSM 980 with Airyscan 2</​a><​br>​ <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​confocal-microscopes/​lsm-980-with-airyscan-2.html">​LSM 980 with Airyscan 2</​a><​br>​
 <​b>​Nickname</​b>:​ "​980"<​br>​ <​b>​Nickname</​b>:​ "​980"<​br>​
-<​b>​Software</​b>:​ ZEN 3.(blue edition)<​br>​+<​b>​Software</​b>:​ ZEN 3.(blue edition)<​br>​
 <​b>​Year</​b>:​ 2021 <br> <​b>​Year</​b>:​ 2021 <br>
 <​b>​SN</​b>:​ 2841000239 <br> <​b>​SN</​b>:​ 2841000239 <br>
 &nbsp <br> &nbsp <br>
 +Data will be deleted after: <b>1 month</​b>​
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
Line 25: Line 26:
 </​table>​ </​table>​
 </​html>​ </​html>​
- 
-** page under construction ** 
  
 ===== Microscope overview ===== ===== Microscope overview =====
  
-{{  :​confocal_pinhole.png?​350}} The Zeiss LSM 980 with Airyscan 2 is a [[https://​www.youtube.com/​watch?​v=rTkjQ6Q0p5I|point-scanning confocal microscope]] able to generate high-resolution three-dimensional images of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted microscope especially suitable for live cell imaging and photobleaching experiments,​ equipped with a dark large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus.for hardware focus control during long time-lapse acquisitions. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions, using the Tiles Advanced Setup of ZEN blue. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan 2]] with 32 concentrically arranged GaAsP detection elements is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (120 nm laterally and 400 nm axially in SR mode, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=tUiEa7vcggQ|Multiplex Mode]], which enables parallel excitation and detection in 4Y or 8Y modes. The result is a speed improvement by a factor of 4x/8x, while maintaining the sensitivity of Airyscan. Its scanning unit further includes two PMT detectors as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional PMT). It is equipped with lasers from violet to far red (405, 488, 561 and 639 nm excitation wavelengths). ​With this system you can perform optical sectioning of fluorescent samples which are too thick for a widefield system such as the [[zeiss_cell_observer|Zeiss Cell Observer]]. Image resolution with Airyscan ​2 is higher than the [[zeiss_lsm_710|Zeiss ​LSM 710]] and detection sensitivity is also higher than the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[colossus|Colossus]].+{{  :​confocal_pinhole.png?​340}} The Zeiss LSM 980 with Airyscan 2 is a [[https://​www.youtube.com/​watch?​v=rTkjQ6Q0p5I|point-scanning confocal microscope]] able to generate high-resolution three-dimensional images of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted microscope especially suitable for live cell imaging and photobleaching experiments,​ equipped with a dark large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus.for hardware focus control during long time-lapse acquisitions. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions, using the Tiles Advanced Setup of ZEN blue. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan 2]] with 32 concentrically arranged GaAsP detection elements is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (120 nm laterally and 350 nm axially in SR mode, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=tUiEa7vcggQ|Multiplex Mode]], which enables parallel excitation and detection in 4Y or 8Y modes. The result is a speed improvement by a factor of 4x/8x, while maintaining the sensitivity of Airyscan. Its scanning unit further includes two PMT detectors as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional PMT). It is equipped with lasers from violet to far red (405, 488, 561 and 639 nm excitation wavelengths). ​The [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|LSM Plus deconvolution]] mode enhances signal-to-noise ratio by acting as a denoising step post image acquisition,​ allowing for high acquisition speed and low laser powerWith [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|Airyscan ​Joint Deconvolution (jDCV)]] ​the resolution can be improved to 90 nm (XY) and 270 nm (Z). 
 + 
 +  * **Microscope**: ​[[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research.html|Zeiss ​Axio Observer]] 
 +  * **LED Illumination**: ​[[https://​www.zeiss.com/​microscopy/​en/​products/​accessories/​colibri.html|Zeiss Colibri 7]] 
 +  * **Features** 
 +    * |  ​[[https://​www.imdik.pan.pl/​images/​Us%C5%82ugi_dokumenty/​Przydatne_informacje/​2d_Definite_Focus_information.pdf|Definite Focus.3]] 
 +    * | [[https://​www.youtube.com/​watch?​v=tUiEa7vcggQ|Airyscan 2 Multiplex]] 
 +    * | [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|LSM Plus]] 
 +    * | [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|Joint Deconvolution]]
  
 <​html>​ <​html>​
Line 36: Line 43:
 </​html>​ </​html>​
  
-{{:warning.png?25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.+  * [[https://www.youtube.com/​watch?v=zA4xqq-EL9g|ZEISS Webinar: LSM 980 Airyscan 2 Multiplex mode]]
  
-===== Additional information ===== +{{:warning.png?25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
- +
-  * [[https://www.youtube.com/​watch?v=zA4xqq-EL9g|ZEISS Webinar: Exploring ​the advancements in fast and gentle super-resolution imaging with LSM 980 Airyscan 2 Multiplex mode (video)]]+
  
 ===== Booking Rules ===== ===== Booking Rules =====
Line 62: Line 67:
 |  40x  |  LD C-Apochromat Corr  |  Water  |  1.10  |  0.62  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421867-9970-000/​Objective-LD-C-Apochromat-40x-1.1-W-Corr-M27|421867-9970-000]] ​ | |  40x  |  LD C-Apochromat Corr  |  Water  |  1.10  |  0.62  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421867-9970-000/​Objective-LD-C-Apochromat-40x-1.1-W-Corr-M27|421867-9970-000]] ​ |
 |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ | |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ |
-==== Filtersets ​(Ocular) ====+ 
 +==== LEDs (Ocular) ==== 
 +^  Line  ^  Wavelength ​ ^ 
 +|  UV  |  385 nm  | 
 +|  B  |  475 nm  | 
 +|  G  |  555 nm  | 
 +|  R  |  630 nm  | 
 + 
 +==== Filterset ​(Ocular) ====
  
 ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^ ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^
-|  1  |  ​Green  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=7139069fdc79c&​l=en&p=us&​f=f&​a=v&​b=f&​id=489038-9901-000&o=|FS38HE]]  |  ​450-490 nm  |  ​495 nm  |  ​500-550 nm  | +|  1  |  ​QUAD  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/us/​shop/​filterAssistant/​filtersets/​489090-9100-000|  ​FS90HE]]  |  ​370-400 nm  |  ​405 nm  |  ​410-440 nm  | 
-|  ​ ​|  ​Red  ​|  ​[[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1114-101&​o=|FS43]] ​ ​|  ​533-558 nm  |  ​570 nm  |  ​570-640 nm  | +|  ​:::  ​|  ​:::  ​| ​ :::  ​|  ​450-488 nm  |  ​493 nm  |  ​499-529 nm  | 
-|  ​ ​|  ​Blue  ​|  ​[[https://www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ ​|  ​G 365 nm  |  ​395 nm  |  ​420-470 nm  |+|  ​:::  ​|  ​:::  ​| ​ :::  |  540-570 nm  |  575 nm  |  580-605 nm  ​| 
 +|  :::  ​|  ​:::  |  :::  |  615-648 ​nm  |  ​653 nm  |  ​659-759 nm  |
  
 ===== Microscope Turn On Procedure ===== ===== Microscope Turn On Procedure =====
 +
 +The system should be always on, you should only need to turn on the computer, log into Windows and start **ZEN**.
 +
 +If the system is completely off (e.g. during weekends), please follow this procedure:
 +
   * Turn on the ''​MAIN SWITCH''​   * Turn on the ''​MAIN SWITCH''​
-{{zeiss_lsm_880_1.jpg?100}} +{{::​zeiss_lsm_980_main_switch.png?100|}} 
-  * Turn on the ''​SYSTEMS/PC'' ​switch+  * Turn on the ''​Laser'' ​key 
 +{{::​zeiss_lsm_980_laser_key.png?​100|}}
   * Turn on the computer   * Turn on the computer
-  * Login in to Windows ​(Bioimaging User)+  * Log into Windows ​with your Agendo credentials
   * Turn on the ''​COMPONENTS''​ switch   * Turn on the ''​COMPONENTS''​ switch
-  ​* Start the **ZEN Black** software+{{::​zeiss_lsm_980_components.png?​100|}} 
 +  ​* Start the **ZEN** software
  
 ===== Microscope Turn Off Procedure ===== ===== Microscope Turn Off Procedure =====
-If there is another user for this microscope in the __next hour__: + 
-  * Exit the ZEN software, leave the lasers on +Please do not shutdown ​the system. Just exit the **ZEN** software, log off Windows and shutdown ​the computer. 
-  * Log off the computer +Don't forget ​to clean immersion objectives!
-  * Clean up immersion objectives +
-Else: +
-  * Turn off the lasers on **ZEN** +
-  * Clean up immersion objectives +
-  * Exit the ZEN software +
-  * Shutdown ​the computer +
-  * Turn off the two switches ​''​SYSTEMS/​PC''​ and ''​COMPONENTS''​ +
-  * **Wait 5 min. for Ar laser to cool down** +
-  * Turn off the ''​MAIN SWITCH''​+
  
 ---- ----
 [[resources|Back to the Equipment page]] [[resources|Back to the Equipment page]]