User Tools

Site Tools


zeiss_lsm_880

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
zeiss_lsm_880 [2020/07/21 23:22]
bioimaging
zeiss_lsm_880 [2024/01/28 11:47] (current)
bioimaging [Microscope overview]
Line 4: Line 4:
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_new.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_new.png" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_2022.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_wiki_2022.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
 <​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_map_new.png">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47217) <​br> ​ <​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_880_map_new.png">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47217) <​br> ​
-<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​ +<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​ 
-<​b>​Model</​b>:​ LSM 880 with Airyscan<​br>​+<​b>​Model</​b>: ​<a href="​https://​www.youtube.com/​watch?​v=sGTNBXq8omg">​LSM 880 with Airyscan</a> (click for Zeiss webinar) ​<br>
 <​b>​Nickname</​b>:​ "​880"<​br>​ <​b>​Nickname</​b>:​ "​880"<​br>​
-<​b>​Software</​b>:​ ZEN 2.(black) <br>+<​b>​Software</​b>:​ ZEN 2.3 SP1 (black ​edition) <br>
 <​b>​Year</​b>:​ 2016 <br> <​b>​Year</​b>:​ 2016 <br>
 <​b>​SN</​b>:​ 2811000267 <br> <​b>​SN</​b>:​ 2811000267 <br>
 +&nbsp <br>
 +Data will be deleted after: <b>1 month</​b>​
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​my.agendo.science/​calendar/?​id=OGNhbGVuZGFycw=="><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss LSM 880 Booking</​a>​ 
- <​br> ​ 
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss LSM 880 Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_lsm_880_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss LSM 880 Quality Control</​a>​
  <​br>​  <​br>​
Line 29: Line 29:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-{{  :airyscan_beampath.png?400}} The Zeiss LSM 880 with Airyscan is a //confocal ​point-scanning microscope// able to generate high-resolution three-dimensional images of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted microscope especially suitable for live cell imaging and photobleaching experiments,​ equipped with a large size incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan]] 32 channel area detector ​is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (140 nm laterally and 400 nm axially, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=ln6VUmLzLLc|Fast Mode]], which enables parallel excitation and detection of four image pixels. The result is a speed improvement by a factor ​of four, while maintaining the sensitivity of Airyscan and 1.5x resolution improvement. Its scanning unit further includes two PMT detectors (one of them cooled) as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional PMT). It is equipped with lasers from violet to far red (405, 458, 488, 514, 561, 594 and 633 nm excitation wavelengths).  +{{  :confocal_pinhole.png?340}} The Zeiss LSM 880 with Airyscan is a [[https://www.youtube.com/​watch?​v=rTkjQ6Q0p5I|point-scanning ​confocal ​microscope]] able to generate high-resolution three-dimensional images of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted microscope especially suitable for live cell imaging and photobleaching experiments,​ equipped with a large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan]] ​with 32 concentrically arranged GaAsP detection elements ​is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (140 nm laterally and 400 nm axially, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=ln6VUmLzLLc|Fast Mode]], which enables parallel excitation and detection of four image pixels. The result is a speed improvement by a factor ​4x, while maintaining the sensitivity of Airyscan and 1.5x resolution improvement. Its scanning unit further includes two PMT detectors (one of them cooled) as well as a GaAsP detector for increased sensitivity (45% QE compared to ~25% QE for conventional PMT). It is equipped with lasers from violet to far red (405, 458, 488, 514, 561, 594 and 633 nm excitation wavelengths).
-{{::​fast_airyscan.png?​420 ​ }}With this system you can perform optical sectioning of fluorescent samples which are too thick for a widefield system such as the [[zeiss_cell_observer|Zeiss Cell Observer]] or the [[zeiss_axiovert_200m|Zeiss Axiovert 200M]]. Image resolution with Airyscan is higher than the [[zeiss_lsm_710|Zeiss LSM 710]] and detection sensitivity is also higher than the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]].+
  
-{{:info.png?25|}} Click [[https://imm.medicina.ulisboa.pt/facility/bioimaging/lib/exe/fetch.php?​cache=&media=airyscan.jpg|here]] to see the system beam path in higher detail+  * [[https://www.youtube.com/​watch?v=sGTNBXq8omg|ZEISS Webinar: LSM 880 with Airyscan - Revolutionize Your Confocal Imaging]] 
 +  * [[https://www.youtube.com/watch?​v=VuxgaKDa_DU|ZEISS Webinar: Fast Mode for ZEISS LSM 880 with Airyscan]] 
 + 
 +<​html>​ 
 +<p align="​center"><​iframe width="​420"​ height="​236"​ src="​https:​//www.youtube.com/embed/QjKrLTHGnc8"​ title="​YouTube video player"​ frameborder="​0"​ allow="​accelerometer;​ autoplay; clipboard-write;​ encrypted-media; gyroscope; picture-in-picture"​ allowfullscreen></​iframe>​ <iframe width="​420"​ height="​236"​ src="​https://​www.youtube.com/​embed/​ln6VUmLzLLc"​ title="​YouTube video player"​ frameborder="​0"​ allow="​accelerometer;​ autoplay; clipboard-write;​ encrypted-media;​ gyroscope; picture-in-picture"​ allowfullscreen></​iframe></​p>​ 
 +</​html>​
  
 {{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. {{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
Line 44: Line 48:
  
 ==== LASERs ==== ==== LASERs ====
-^  Laser Unit  ^  Wavelength ​ ^  Maximum Power  ​^ ​ Current Status ​ ^ +^  Laser Unit  ^  Wavelength ​ ^  Maximum Power  ^ 
-|  Diode 405-30 ​ |  405 nm  |  30 mW  ​| ​ ok  | +|  Diode 405-30 ​ |  405 nm  |  30 mW  | 
-|  Argon  |  458, 488 and 514 nm  |  25 mW  ​| ​ ok  | +|  Argon  |  458, 488 and 514 nm  |  25 mW  | 
-|  DPSS 561-20 ​ |  561 nm  |  20 mW  ​| ​ ok  | +|  DPSS 561-20 ​ |  561 nm  |  20 mW  | 
-|  HeNe594 ​ |  594 nm  |  2 mW  ​| ​ ok  | +|  HeNe594 ​ |  594 nm  |  2 mW  | 
-|  HeNe633 ​ |  633 nm  |  5 mW  ​| ​ ok  |+|  HeNe633 ​ |  633 nm  |  5 mW  |
  
 ==== Objectives ==== ==== Objectives ====
Line 56: Line 60:
 |  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]] ​ | |  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]] ​ |
 |  40x  |  C-Apochromat Corr  |  Water  |  1.20  |  0.28  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421767-9970-000/​Objective-C-Apochromat-40x-1.20-W-Corr-M27|421767-9970-000]] ​ | |  40x  |  C-Apochromat Corr  |  Water  |  1.20  |  0.28  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421767-9970-000/​Objective-C-Apochromat-40x-1.20-W-Corr-M27|421767-9970-000]] ​ |
 +|  40x  |  LD C-Apochromat Corr  |  Water  |  1.10  |  0.62  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​421867-9970-000/​Objective-LD-C-Apochromat-40x-1.1-W-Corr-M27|421867-9970-000]] ​ |
 |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ | |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-799/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-799]] ​ |
  
Line 64: Line 69:
 |  25x  |  LCI Plan-Neofluar Corr DIC  |  Oil/​Glyc/​W ​ |  0.80  |  0.21  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420852-9973-000/​Objective-LCI-Plan-Neofluar-25x-0.8-Imm-Corr-DIC-M27|420852-9972-000]] ​ | |  25x  |  LCI Plan-Neofluar Corr DIC  |  Oil/​Glyc/​W ​ |  0.80  |  0.21  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420852-9973-000/​Objective-LCI-Plan-Neofluar-25x-0.8-Imm-Corr-DIC-M27|420852-9972-000]] ​ |
 |  40x  |  Plan-Apochromat Corr  |  Dry  |  0.95  |  0.25  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/​Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]] ​ | |  40x  |  Plan-Apochromat Corr  |  Dry  |  0.95  |  0.25  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/​Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]] ​ |
-|  100x  |  α Plan-Apochromat DIC  |  Oil  |  1.46  |  0.11  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420792-9800-000/​Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27|420792-9800-000]] ​ | 
 ==== Filtersets (Ocular) ==== ==== Filtersets (Ocular) ====
  
 ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^ ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^
-|  ​ ​| ​ Green  |  [[https://​www.micro-shop.zeiss.com/?​s=7139069fdc79c&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489038-9901-000&​o=|FS38HE]] ​ |  450-490 nm  |  495 nm  |  500-550 nm  | +|  ​2  |  Cyan  |  [[https://​www.chroma.com/​products/​sets/​49001-et-ecfp|49001]] ​ |  426-446 nm  |  455 nm  |  460-500 nm  | 
-|  ​ ​| ​ Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1114-101&​o=|FS43]] ​ |  533-558 nm  |  570 nm  |  570-640 nm  | +|  3  ​| ​ Green  |  [[https://​www.micro-shop.zeiss.com/?​s=7139069fdc79c&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489038-9901-000&​o=|FS38HE]] ​ |  450-490 nm  |  495 nm  |  500-550 nm  | 
-|  ​ ​| ​ Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ |  G 365 nm  |  395 nm  |  420-470 nm  |+|  ​ ​| ​ Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=000000-1114-101&​o=|FS43]] ​ |  533-558 nm  |  570 nm  |  570-640 nm  | 
 +|  ​ ​| ​ Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ |  G 365 nm  |  395 nm  |  420-470 nm  |
  
 ===== Microscope Turn On Procedure ===== ===== Microscope Turn On Procedure =====
   * Turn on the ''​MAIN SWITCH''​   * Turn on the ''​MAIN SWITCH''​
-  * Turn on the two switches: ''​SYSTEMS/​PC''​ and ''​COMPONENTS''​ 
 {{zeiss_lsm_880_1.jpg?​100}} {{zeiss_lsm_880_1.jpg?​100}}
 +  * Turn on the ''​SYSTEMS/​PC''​ switch
   * Turn on the computer   * Turn on the computer
-  * Login in to Windows ​(Bioimaging User)+  * Login in to Windows ​with your Agendo credentials 
 +  * Turn on the ''​COMPONENTS''​ switch
   * Start the **ZEN Black** software   * Start the **ZEN Black** software
  
Line 95: Line 101:
  
 ---- ----
-[[resources|Back to the Resources ​page]]+[[resources|Back to the Equipment ​page]]
zeiss_lsm_880.1595366526.txt.gz · Last modified: 2020/07/21 23:22 by bioimaging