User Tools

Site Tools


zeiss_cell_observer_wf

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
zeiss_cell_observer_wf [2016/04/05 16:26]
bioimaging
zeiss_cell_observer_wf [2016/06/29 11:10]
bioimaging removed
Line 8: Line 8:
 <​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wf_map.jpg">​Room P3-A-10</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif"​ width=15>​ 47311) <​br> ​ <​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wf_map.jpg">​Room P3-A-10</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif"​ width=15>​ 47311) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​
-<​b>​Model</​b>: ​Cell Observer<​br>​+<​b>​Model</​b>: ​Axio Observer<​br>​
 <​b>​Software</​b>:​ ZEN 2 (blue edition)<​br>​ <​b>​Software</​b>:​ ZEN 2 (blue edition)<​br>​
 <​b>​Year</​b>:​ 2015 <br> <​b>​Year</​b>:​ 2015 <br>
Line 16: Line 16:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=ZEISSCELL1&​rid=125"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Cell Observer WF Booking</​a>​+&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​125"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Cell Observer WF Booking</​a>​
  <​br> ​  <​br> ​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_cell_observer_wf_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Cell Observer WF Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_cell_observer_wf_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Cell Observer WF Quality Control</​a>​
Line 27: Line 27:
 </​html>​ </​html>​
  
 +===== Microscope overview =====
 +The Zeiss Cell Observer WF is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a large cage incubator and a small stage incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN 2 software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled Axiocam 506m camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If don't want to use deconvolution,​ check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]], the [[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.
 +
 +===== Booking Rules =====
 +The Zeiss Cell Observer WF booking is divided in three daily slots:
 +|  9:00 to 13:00  |  13:00 to 17:00  |  17:00 to 21:00  |
 +
 +  - A **user** can book at maximum **2 sessions per week**
 +  - Each **session must fit inside one of the three daily slots** (i.e. a session booked from 11:00 to 14:00 counts as 2 sessions)
 +  - The above rules do not apply for **weekends** and for work days **before 9:00** and **after 21:00**
 +  - The above rules do not apply for sessions booked on the very same day or **24 hours ahead**
 +  - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**.
 +  - Users must indicate which lasers they are going to use in the booking Description field
 +  - Users must indicate if they will use the incubator in the booking Description field (write down 37C INCUBATOR)
 +  - Users must write their internal extension phone number in the booking Description field
 +
 +===== System components =====
 +
 +==== Filtersets ====
 +
 +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^
 +|  1  |  HE GFP  |  [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489038-9901-000&​o=|FS38HE]] ​ |  450-490 nm  |  500-550 nm  |
 +|  2  |  HE DsRed  |  [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489043-9901-000&​o=|FS43HE]] ​ |  538-562 nm  |  570-640 nm  |
 +|  3  |  DAPI  |  [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]] ​ |  335-383 nm  |  420-470 nm  |
 +|  4  |  Cy5  |  [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488050-9901-000&​o=|FS50]] ​ |  625-655 nm  |  665-715 nm  |
 +|  5  |  none  |  none  |  none  |  none  |
 +|  6  |  none  |  none  |  none  |  none  |
 +
 +==== Objectives ====
 +^  Magnification ​ ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^
 +|  10x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420340-9901-000|EC Plan-Neofluar]] ​ |  Dry  |  0.30  |  5.2  |
 +|  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=2310860526ae9cb&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420650-9901-000|Plan-Apochromat]] ​ |  Dry  |  0.80  |  0.55  |
 +|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440350-9903-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.75  |  0.71  |
 +|  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420782-9900-000|Plan-Apochromat]] ​ |  Oil  |  1.40  |  0.19  |
 +
 +**Upon request:**
 +^  Magnification ​ ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^
 +|  1.25x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=422310-9900-000|EC Epiplan-Neofluar]] ​ |  Dry  |  0.035  |  4  |
 +|  5x  |  [[https://​www.micro-shop.zeiss.com/?​s=571974962233f6&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420330-9901-000|EC Plan-NeoFluar]] ​ |  Dry  |  0.16  |  18.5  |
 +|  20x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440341-9904-000|EC Plan-Neofluar Ph 2]]  |  Dry  |  0.50  |  2  |
 +|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=129353259d52f12&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420660-9970-000|Plan-Apochromat]] ​ |  Dry  |  0.95  |  0.25  |
 +|  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar Ph3]]  |  Oil  |  1.30  |  0.20  |
 +|  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat Ph3]]  |  Oil  |  1.4  |  0.19  |
 +|  100x  |  [[https://​www.micro-shop.zeiss.com/?​s=7138707e1a1de&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420792-9800-000|alpha Plan-Apochromat]] ​ |  Oil  |  1.46  |  0.11  |
 +
 +===== System Turn On Procedures =====
 +  * Turn on the HXP 120 fluorescence light.
 +{{zeiss_cell_observer_wf_hxp.jpg?​120|}}
 +  * Turn on the Temperature and CO2 controller (if you need them).
 +{{zeiss_cell_observer_wf_temp.jpg?​80|}}
 +  * If you need CO2, open the valve
 +{{zeiss_cell_observer_wf_co2.jpg?​80|}}
 +  * Turn on the Motorized Stage controller (A)
 +{{zeiss_cell_observer_wf_a.jpg?​height=150|}}
 +  * Turn on the Definite Focus controller (if you are going to use it)
 +{{zeiss_cell_observer_wf_df.jpg?​height=150|}}
 +  * Turn on the Microscope power supply (B)
 +{{zeiss_cell_observer_wf_b.jpg?​height=150|}}
 +  * Turn on the computer
 +  * Log in Windows with your lab user account (each lab has it's own area and login).
 +  * Start the **ZEN 2** software
 +
 +===== Microscope Turn Off procedures =====
 +  * Exit the **ZEN 2** software
 +  * Turn off the computer
 +  * If you used any __immersion oil in the objectives, clean them up__.
 +  * Turn off the microscope power supply (B)
 +  * Turn off the Definite Focus controller (if used)
 +  * Turn off the Motorized Stage controller (A)
 +  * Turn off the Temperature and CO2 controller (if used)
 +  * If there'​s __another user__ for this microscope in the __next hour__ leave the mercury __lamp power source on, else turn it off__. ​
 +  * Be extra careful in weekends and at the end of the day to make sure that the mercury lamp is not going to be turned on for an excessive time. 
 +
 +----
 +[[resources|Back to the Resources page]]