User Tools

Site Tools


zeiss_cell_observer

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
zeiss_cell_observer [2020/11/06 16:29]
bioimaging
zeiss_cell_observer [2024/01/31 10:47]
bioimaging
Line 4: Line 4:
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wiki_new.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wiki_new.png" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wiki_2022.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_wiki_2022.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_map_new.png">​Room ​P3-A-10</a> (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15> ​47331) <br>  +<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_cell_observer_map_new_p2a24.png">​Room ​P2-A-24</a> (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15> ​47219) <br>  
-<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​+<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​
 <​b>​Model</​b>:​ Axio Observer<​br>​ <​b>​Model</​b>:​ Axio Observer<​br>​
 <​b>​Nickname</​b>:​ "Cell Observer"<​br>​ <​b>​Nickname</​b>:​ "Cell Observer"<​br>​
-<​b>​Software</​b>:​ ZEN (blue edition)<​br>​+<​b>​Software</​b>:​ ZEN 3.0 (blue edition)<​br>​
 <​b>​Year</​b>:​ 2015 <br> <​b>​Year</​b>:​ 2015 <br>
 <​b>​SN</​b>:​ 3851002396<​br>​ <​b>​SN</​b>:​ 3851002396<​br>​
 +&nbsp <br>
 +Data will be deleted after: <b>15 days</​b>​
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​my.agendo.science/​calendar/?​id=MjZjYWxlbmRhcnM="><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Cell Observer Booking</​a>​ 
- <​br> ​ 
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_cell_observer_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Cell Observer Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_cell_observer_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Cell Observer Quality Control</​a>​
  <​br>​  <​br>​
Line 28: Line 28:
  
 ===== Microscope overview ===== ===== Microscope overview =====
-{{  :​widefield_lightpath.png?​0x300}}The Zeiss Cell Observer is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging with fast acquisition speeds. It is equipped with a large cage incubator and a small stage incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. The stage is furthermore equipped with a piezo for fast Z displacement. You can choose between a HXP metal halide lamp or fast-switching LEDs for illumination. Its sensitive ​cooled Axiocam 506m camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. ​You can also perform Z-stack acquisition and use [[https://huygens.i3s.up.pt/login.php|PPBI Huygens RM]] [[http://micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server to significantly improve image resolution ​even in thick samples. If don't want to use deconvolution,​ check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]].+{{  :​widefield_lightpath.png?​0x300}}The Zeiss Cell Observer is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging with fast acquisition speeds. It is equipped with a large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. The stage is furthermore equipped with a piezo for fast Z displacement. You can choose between a HXP metal halide lamp or fast-switching LEDs for illumination. Its cooled ​[[https://​asset-downloads.zeiss.com/​catalogs/​download/​mic/​a8e5b4d7-25f6-4069-8f03-c6713d044c87/​EN_product-info_Axiocam-506_mono.pdf|Axiocam 506m]] camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. ​It is also equipped with a high sensitivity ​[[https://www.photometrics.com/products/prime-family/primebsiexpress|Photometrics Prime BSI Express]] sCMOS camera for high resolution ​imaging with maximized signal detection.
  
-  * **Microscope**:​ [[http://​www.zeiss.com/​microscopy/​en_de/products/light-microscopes/axio-observer-for-biology.html|Zeiss ​Axio Observer]] +  * **Microscope**: Zeiss Axio Observer 
-  * **LED Illumination**: [[https://www.zeiss.com/microscopy/int/products/microscope-components/lightsources/​colibri-7.html?​vaURL=www.zeiss.de/​colibri|Zeiss Colibri 7]] +  * **LED Illumination**: [[https://​www.zeiss.com/​microscopy/​en/products/accessories/colibri.html|Zeiss ​Colibri 7]] 
-  * **Camera**: [[https://​www.zeiss.com/​microscopy/​int/products/microscope-cameras/axiocam-506-mono.html|Axiocam 506 mono CCD]]+  * **Camera** (left port): [[https://asset-downloads.zeiss.com/catalogs/download/mic/a8e5b4d7-25f6-4069-8f03-c6713d044c87/EN_product-info_Axiocam-506_mono.pdf|Axiocam 506 mono CCD]] 
 +  * **Camera** ​(right port): [[https://​www.photometrics.com/​products/​prime-family/primebsiexpress|Photometrics Prime BSI Express sCMOS]]
  
-{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.+{{::​phenocycler.png?​260 ​ |}}This system is also set up to work together with the [[https://​www.youtube.com/​watch?​v=OQGJX45Wsgw|AKOYA PhenoCycler]] fluidics instrument for automated iterative imaging cycles of whole slide tissues for [[https://​www.akoyabio.com/​why-spatial-biology/​|Spatial Biology]] applications,​ such as image-based quantification of biomarkers to predict immunotherapy response, or quantification of cells by lineage and variant with single-cell resolution in the context of an intact tissue sample. 
 + 
 +  * [[https://​www.youtube.com/​watch?​v=OQGJX45Wsgw|Understanding the PhenoCycler Technology]]  
 +  * [[https://​www.akoyabio.com/​webinar/​a-beginners-guide-to-codex/​|A Beginner’s Guide to CODEX]] 
 +  * [[https://​www.akoyabio.com/​webinar/​spatial-phenotyping-a-revolutionary-approach-to-biomarker-discovery-for-cancer-immunotherapy/​|Spatial Phenotyping:​ A Revolutionary Approach to Biomarker Discovery for Cancer Immunotherapy]] 
 + 
 +{{:​warning.png?​25|}} Data files older than **15 days** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
  
 ===== Booking Rules ===== ===== Booking Rules =====
Line 42: Line 49:
  
 ===== System components ===== ===== System components =====
 +
 +==== LEDs  ====
 +^  Line  ^  Wavelength ​ ^
 +|  UV  |  385 nm  |
 +|  B  |  475 nm  |
 +|  G  |  555 nm  |
 +|  Y  |  590 nm  |
 +|  R  |  630 nm  |
  
 ==== Filtersets ==== ==== Filtersets ====
Line 48: Line 63:
 |  1  |  HE GFP  |  [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489038-9901-000&​o=|FS38HE]] ​ |  450-490 nm  |  495 nm  |  500-550 nm  | |  1  |  HE GFP  |  [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489038-9901-000&​o=|FS38HE]] ​ |  450-490 nm  |  495 nm  |  500-550 nm  |
 |  2  |  HE DsRed  |  [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489043-9901-000&​o=|FS43HE]] ​ |  538-562 nm  |  570 nm  |  570-640 nm  | |  2  |  HE DsRed  |  [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=489043-9901-000&​o=|FS43HE]] ​ |  538-562 nm  |  570 nm  |  570-640 nm  |
-|  3  |  ​DAPI  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]]  |  ​335-383 nm  |  ​395 nm  |  ​420-470 nm  | +|  3  |  ​Cy5  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488050-9901-000&​o=|FS50]]  |  ​625-655 nm  |  ​660 nm  |  ​665-715 nm  | 
-|  4  |  ​Cy5  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488050-9901-000&​o=|FS50]]  |  ​625-655 nm  |  ​660 nm  |  ​665-715 nm  ​+|  4  |  ​Analyzer DIC  ||||| 
-|  5  |  Empty  ||||| +|  5  |  QUAD  |  [[https://​www.micro-shop.zeiss.com/​en/​us/​shop/​filterAssistant/​filtersets/​489090-9100-000|FS90HE]] |  370-400 nm  |  405 nm  |  410-440 nm  | 
-|  6  |  Empty  |||||+|  :::  |  :::  |  :::  |  450-488 nm  |  493 nm  |  499-529 nm  | 
 +|  :::  |  :::  |  :::  |  540-570 nm  |  575 nm  |  580-605 nm  | 
 +|  :::  |  :::  |  :::  |  615-648 nm  |  653 nm  |  659-759 nm  | 
 +|  6  |  DAPI  ​| ​ [[https://​www.micro-shop.zeiss.com/?​s=23108437692794b&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488049-9901-000&​o=|FS49]]  |  ​335-383 nm  |  ​395 nm  |  ​420-470 nm  |
  
 ==== Objectives ==== ==== Objectives ====
 ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
 |  10x  |  EC Plan-Neofluar Ph1  |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420341-9911-000/​Objective-EC-Plan-Neofluar-10x-0.30-Ph1-M27|420341-9911-000]] ​ | |  10x  |  EC Plan-Neofluar Ph1  |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420341-9911-000/​Objective-EC-Plan-Neofluar-10x-0.30-Ph1-M27|420341-9911-000]] ​ |
-|  20x  |  EC Plan-Neofluar Ph 2  |  Air  |  0.50  |  2.00  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440341-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5-Ph2|440341-9904-000]] ​ | 
 |  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]] ​ | |  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]] ​ |
 +|  20x  |  EC Plan-Neofluar Ph 2  |  Air  |  0.50  |  2.00  |  [[https://​www.micro shop.zeiss.com/​en/​de/​shop/​objectives/​440341-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5-Ph2|440341-9904-000]] ​ |
 |  40x  |  EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420360-9900-000/​Objective-EC-Plan-Neofluar-40x-0.75-M27|420360-9900-000]] ​ | |  40x  |  EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420360-9900-000/​Objective-EC-Plan-Neofluar-40x-0.75-M27|420360-9900-000]] ​ |
 |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ | |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |
Line 67: Line 85:
 |  5x  |  EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.50  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ | |  5x  |  EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.50  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ |
 |  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ | |  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ |
 +|  25x  |  LCI Plan-Neofluar Corr DIC  |  Oil/​Glyc/​W ​ |  0.80  |  0.21  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420852-9973-000/​Objective-LCI-Plan-Neofluar-25x-0.8-Imm-Corr-DIC-M27|420852-9972-000]] ​ |
 |  40x  |  Plan-Apochromat Corr  |  Air  |  0.95  |  0.25  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/​Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]] ​ | |  40x  |  Plan-Apochromat Corr  |  Air  |  0.95  |  0.25  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/​Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]] ​ |
 |  40x  |  Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ | |  40x  |  Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ |
Line 74: Line 93:
 ^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^ ^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^
 |  [[https://​www.zeiss.com/​microscopy/​int/​products/​microscope-cameras/​axiocam-506-mono.html|Axiocam 506 mono]] ​ |  CCD  |  2752 x 2208  |  4.54 x 4.54  | |  [[https://​www.zeiss.com/​microscopy/​int/​products/​microscope-cameras/​axiocam-506-mono.html|Axiocam 506 mono]] ​ |  CCD  |  2752 x 2208  |  4.54 x 4.54  |
 +
 ===== System Turn On Procedures ===== ===== System Turn On Procedures =====
-  ​* Turn on the HXP 120 fluorescent light source+ 
 +  ​* Turn on the HXP 120 fluorescent light source ​(if used)
 {{zeiss_axio_observer_hxp.jpg?​120|}} {{zeiss_axio_observer_hxp.jpg?​120|}}
-  * Turn on the temperature and CO2 controller (if you need them). +  * Turn on the temperature and CO2 controller ​- white power strip (if you need them). 
-{{zeiss_axio_observer_temp.jpg?​80|}} +  * If you need CO2, open the Cell Observer CO2 valve 
-  * If you need CO2, open the valve +  * Turn on the motorized stage controller (**1** on remote control)
-{{zeiss_axio_observer_co2.jpg?​80|}} +
-  * Turn on the motorized stage controller (**A** on remote control)+
 {{zeiss_axio_observer_a.jpg?​height=150|}} {{zeiss_axio_observer_a.jpg?​height=150|}}
-  ​* Turn on the Definite Focus controller (if you are going to use it) +  * Turn on the microscope power supply (**2** on remote control)
-{{zeiss_axio_observer_df.jpg?​height=150|}} +
-  ​* Turn on the microscope power supply (**B** on remote control)+
 {{zeiss_axio_observer_b.jpg?​height=150|}} {{zeiss_axio_observer_b.jpg?​height=150|}}
   * Turn on the computer   * Turn on the computer
-  * Log in to Windows ​(Biomaging User).+  * Login in to Windows ​with your Agendo credentials
   * Start the **ZEN** software   * Start the **ZEN** software
- +  * Select HXP or LED Workspace in ZEN (top left) 
-**Warning**If you need to change the stage adapter, please contact the <​html><​a href="/​facility/​bioimaging/​doku.php?id=about">​Bioimaging Unit</​a>​ (<​b>​imm-bioimaging@medicina.ulisboa.pt</​b> ​<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47222</​html>​)+{{::​workspace_selection.png?250|}}
  
 ===== Microscope Turn Off procedures ===== ===== Microscope Turn Off procedures =====
Line 102: Line 119:
 {{:​cell_observer_pc_vs_ups.png?​250|}} {{:​cell_observer_pc_vs_ups.png?​250|}}
   * Clean up immersion objectives   * Clean up immersion objectives
-  * Turn off the microscope power supply (**B** on remote control+  * Turn off the microscope power supply (**2** on remote control) 
-  * Turn off the Definite Focus controller (if used+  * Turn off the motorized stage controller (**1** on remote control) 
-  * Turn off the motorized stage controller (**A** on remote control) +  * Turn off the Temperature and CO2 controller ​- white power strip (if used) 
-  * Turn off the Temperature and CO2 controller (if used) +  * Close the Cell Observer CO2 valve (if used) 
-  * Turn off the HXP 120 fluorescent light source+  * Turn off the HXP 120 fluorescent light source ​(if used)
  
 ---- ----
-[[resources|Back to the Resources ​page]]+[[resources|Back to the Equipment ​page]]
zeiss_cell_observer.txt · Last modified: 2024/04/01 23:50 by bioimaging