Previous revision
zeiss_axiovert_200m [2023/03/27 13:09]
bioimaging
zeiss_axiovert_200m [2024/02/12 22:50]
bioimaging
Line 10: Line 10:
 <​b>​Model</​b>:​ Axiovert 200M<​br>​ <​b>​Model</​b>:​ Axiovert 200M<​br>​
 <​b>​Nickname</​b>:​ "​Axiovert"<​br>​ <​b>​Nickname</​b>:​ "​Axiovert"<​br>​
-<​b>​Software</​b>:​ Metamorph 7.7.9.0<​br>​+<​b>​Software</​b>:​ Metamorph 7.8.0.0<​br>​
 <​b>​Year</​b>:​ 2003 <br> <​b>​Year</​b>:​ 2003 <br>
 <​b>​SN</​b>:​ ZCA522000494<​br>​ <​b>​SN</​b>:​ ZCA522000494<​br>​
Line 29: Line 29:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-{{  :​widefield_lightpath.png?​0x300}}The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Photometrics CoolSNAP HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. ​You can also perform Z-stack acquisition and use [[https://huygens.i3s.up.pt/login.php|PPBI Huygens RM]] [[http://micro.magnet.fsu.edu/primer/digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous mediaand need hardware focus control, check the [[zeiss_cell_observer|Zeiss Cell Observer]] ​with Definite Focus or the [[nikon_eclipse_ti|Nikon Eclipse Ti]]. If don't want to use deconvolution but need optical sectioning, check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.+{{  :​widefield_lightpath.png?​0x300}}The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera ([[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics CoolSNAP HQ CCD]]) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. ​It is also equipped with a color camera ([[https://www.leica-microsystems.com/products/microscope-cameras/p/leica-dfc450-c/|Leica DFC450]]) for acquisition of histological stains ​with tile and stitching imaging.
  
   * **Microscope**:​ Zeiss Axiovert 200   * **Microscope**:​ Zeiss Axiovert 200