User Tools

Site Tools


zeiss_axiovert_200m

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
zeiss_axiovert_200m [2019/12/31 01:12]
bioimaging
zeiss_axiovert_200m [2020/06/01 19:25]
bioimaging
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=axiovert_200m_name.jpg">+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_name_new.png">
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
Line 6: Line 6:
 <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_new.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_new.png"​ width=300></​a>​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_new.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_new.png"​ width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_map.jpg">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif" width=15>​ 47217) <​br> ​+<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_map_new.png">​Room P2-A-22</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png" width=15>​ 47217) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​
 <​b>​Model</​b>:​ Axiovert 200M<​br>​ <​b>​Model</​b>:​ Axiovert 200M<​br>​
Line 15: Line 15:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/intranet/booking/3"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​+&nbsp <​br>​ 
 +&rarr; <a href="​https://​my.agendo.science/calendar/?​id=MjhjYWxlbmRhcnM="><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​
  <​br> ​  <​br> ​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​
  <​br>​  <​br>​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Axiovert 200M Usage Statistics</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Axiovert 200M Usage Statistics</​a>​
- <​br>​ +</p>
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_repair"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=repair-icon.gif"​ width=16>​ Zeiss Axiovert 200M Repair History</​a>​ +
- </p>+
 </td> </td>
 </tr> </tr>
Line 30: Line 29:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Photometrics ​Coolsnap ​HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server ​[[brainstorm|Brainstorm]] ​to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer|Zeiss Cell Observer]] with Definite Focus. If don't want to use deconvolution,​ check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.+{{  :​widefield_lightpath.png?​0x300}}The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Photometrics ​CoolSNAP ​HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use [[https://​huygens.i3s.up.pt/​login.php|PPBI Huygens RM]] [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer|Zeiss Cell Observer]] with Definite Focus or the [[nikon_eclipse_ti|Nikon Eclipse Ti]]. If don't want to use deconvolution ​but need optical sectioning, check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.
  
   * **Microscope**:​ Zeiss Axiovert 200   * **Microscope**:​ Zeiss Axiovert 200
-  * **Camera**: Photometrics Coolsnap HQ CCD+  * **Monochrome ​Camera**: ​[[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ CCD]] 
 +  * **Color Camera**: [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]]
  
-{{warning.jpg?20|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.+{{:warning.png?25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
  
 ===== Booking Rules ===== ===== Booking Rules =====
Line 51: Line 51:
 ==== Filtersets ==== ==== Filtersets ====
  
-^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^ +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ​^ ​ Dichroic ​ ​^ ​ Emission ​ ^ 
-|  1  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488001-9901-000&​o=|FS01]] ​ |  359-371 nm  |  > 397 nm  | +|  1  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488001-9901-000&​o=|FS01]] ​ |  359-371 ​nm  |  395 nm  |  > 397 nm  | 
-|  2  |  Green BP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488010-9901-000&​o=|FS10]] ​ |  450-490 nm  |  515-565 nm  | +|  2  |  Green BP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488010-9901-000&​o=|FS10]] ​ |  450-490 ​nm  |  510 nm  |  515-565 nm  | 
-|  3  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488020-9901-000&​o=|FS20]] ​ |  540-552 nm  |  575-640 nm  | +|  3  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488020-9901-000&​o=|FS20]] ​ |  540-552 ​nm  |  560 nm  |  575-640 nm  | 
-|  4  |  Far Red  |  [[http://​www.semrock.com/​SetDetails.aspx?​id=2983|Cy5-4040C-000]] ​ |  608-648 nm  |  672-712 nm  | +|  4  |  Far Red  |  [[http://​www.semrock.com/​SetDetails.aspx?​id=2983|Cy5-4040C-000]] ​ |  608-648 ​nm  |  660 nm  |  672-712 nm  | 
-|  5  |  A  |  none  |  ​none  ​ ​none  ​|+|  5  |  A  |  none  ||||
  
 **Upon request:** **Upon request:**
  
-^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Emission ​ ^ +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ​^ ​ Dichroic ​ ​^ ​ Emission ​ ^ 
-|  2  |  Green LP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488009-9901-000&​o=|FS09]] ​ |  450-490 nm  |  > 515 nm  |+|  2  |  Green LP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488009-9901-000&​o=|FS09]] ​ |  450-490 ​nm  |  510 nm  |  > 515 nm  |
  
 ==== Objectives ==== ==== Objectives ====
-^  Magnification ​ ^  Model  ^  ​Type  ​^ ​ NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color ​camera)  10 μm =  ^ +^  Magnification ​ ^  Model  ^  ​Immersion ​ ​^ ​ NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color) ​ 10 μm =  ​^ ​ Reference ​ ^ 
-|  10x  |  ​[[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420340-9901-000|EC Plan-Neofluar]]  ​|  ​Dry  ​| ​ 0.30  |  5. ​| ​ 1.00  |  10 pixels ​ |  23.3 pixels ​ | +|  10x  |  EC Plan-Neofluar ​ |  ​Air  ​| ​ 0.30  |  5.20  ​| ​ 1.00  |  10 pixels ​ |  23.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9900-000/Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9900-000]]  ​
-|  20x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420650-9901-000|EC Plan-Neofluar]] ​ |  ​Dry  ​| ​ 0.50  |  2  |  0.48  |  21 pixels ​ |  46.7 pixels ​ | +|  ​20x  |  EC Plan-Neofluar ​ |  Air  ​| ​ 0.50  |  2.00  ​| ​ 0.48  |  21 pixels ​ |  46.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440340-9904-000/Objective-EC-Plan-Neofluar-20x-0.5|440340-9904-000]]  | 
-|  40x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440350-9903-000|EC Plan-NeoFluar]]  |  ​Dry  ​| ​ 0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ | +|  40x  |  EC Plan-NeoFluar ​ ​|  ​Air  ​| ​ 0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440350-9903-000/​Objective-EC-Plan-Neofluar-40x-0.75|440350-9903-000]]  | 
-|  63x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420782-9900-000|Plan-Apochromat]]  |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |+|  63x  |  Plan-Apochromat DIC  ​| ​ Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |
  
  
 **Upon request:** **Upon request:**
-^  Magnification ​ ^  Model  ^  ​Type  ​^ ​ NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ +^  Magnification ​ ^  Model  ^  ​Immersion ​ ​^ ​ NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ​^ ​ Reference ​ ^ 
-|  1.25x  |  ​[[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=422310-9900-000|EC Epiplan-Neofluar]]  ​|  ​Dry  ​| ​ 0.035  |  4  |  7.58  |  1.3 pixels ​ | +|  1.25x  |  EC Epiplan-Neofluar ​ |  ​Air  ​| ​ 0.035  |  4  |  7.58  |  1.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​422310-9900-000/​Objective-EC-Epiplan-Neofluar-1.25x-0.03-M27|422310-9900-000]] ​ | 
-|  5x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=571974962233f6&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420330-9901-000|EC Plan-NeoFluar]]  ​|  ​Dry  ​| ​ 0.16  |  18.5  |  2.00  |  5 pixels ​ | +|  5x  |  ​EC Plan-NeoFluar ​ |  ​Air  ​| ​ 0.16  |  18.5  |  2.00  |  5 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]]  ​
-|  20x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440341-9904-000|EC Plan-Neofluar ​Ph 2]]  |  ​Dry  ​|  ​0.50  ​|  ​ ​| ​ 0.48  ​|  ​21 pixels ​ +|  ​40x  ​|  ​Plan-Neofluar Ph3  ​|  ​Oil  |  1.30  ​| ​ 0.20  ​|  ​0.24  ​|  ​41 pixels ​ ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]]  | 
-|  ​40x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar Ph3]]  |  Oil  |  1.30  ​| ​ 0.20  ​| ​ 0.24  ​|  ​41 pixels ​ | +|  63x  |  Plan-Apochromat Ph3  ​| ​ Oil  |  1. ​| ​ 0.19  ​| ​ 0.15  ​|  ​65 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420781-9910-000/Objective-Plan-Apochromat-63-1.4-Oil-Ph3-M27|420781-9910-000]]  | 
-|  63x  ​| ​ [[https://​www.micro-shop.zeiss.com/​?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat Ph3]]  |  Oil  |  1. ​| ​ 0.19  ​| ​ 0.15  ​|  ​65 pixels ​ |+|  100x  |  α Plan-Apochromat DIC  ​| ​ Oil  |  1.46  ​| ​ 0.11  ​| ​ 0.09  ​|  ​105 pixels ​ ​| ​ [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420792-9800-000/​Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27|420792-9800-000]] ​ |
  
 *** pixel sizes for binning = 1** *** pixel sizes for binning = 1**
 +
 +==== Cameras ====
 +^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^
 +|  [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ]]  |  CCD  |  1392 x 1040  |  6.45 x 6.45  |
 +|  [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]] ​ |  color CCD  |  2560 × 1920  |  3.4 x 3.4  |
  
 ==== Stage ==== ==== Stage ====
Line 87: Line 92:
  
 ===== System Turn On Procedures ===== ===== System Turn On Procedures =====
-  * Turn the fluorescence ​light power source ​on.+  * Turn on the fluorescent ​light power source
 {{halide_710.jpg?​80|}} {{halide_710.jpg?​80|}}
-  * Turn on the Uniblitz shutter controller (on the back). +  * Turn on the Prior stage controller ​
-{{ax_uniblitz1.jpg?​100|}}{{ax_uniblitz2.jpg?​100|}} +
-  * Turn the Prior microscope ​stage controller ​on. +
 {{ax_prior_on.jpg?​100|}} {{ax_prior_on.jpg?​100|}}
-  * Wait 10s then turn the microscope ​on.+  * Turn on the microscope
 {{ax_mic_on.jpg?​100|}} {{ax_mic_on.jpg?​100|}}
-  * Turn the camera ​on.+  * Turn on the CCD camera
 {{ax_cam_on.jpg?​100|}} {{ax_cam_on.jpg?​100|}}
-  * Turn the computer ​on. +  * Turn on the computer 
-  * Login to the computer ​(Axiovert 200M user). +  * Log in to Windows ​(Bioimaging User
-  * Start the Metamorph software. +  * Start the Metamorph software 
-  * If you need temperature control, turn on the control box +  * If the software doesn'​t detect the camerapower cycle the camera ​and try again
-{{heating2.jpg?​100|}} +
-  * If you need CO2open the valve and turn on CO2 supply on the control box +
-{{co2.jpg?​100|}} +
 ===== Microscope Turn Off procedures ===== ===== Microscope Turn Off procedures =====
-  * Turn off the computer. + 
-  * Turn off the camera. +If there is another user for this microscope in the __next hour__: 
-  * If you used any __immersion oil in the objectives, clean them up__. +  * Leave the fluorescent lamp on 
-  * Turn off the microscope stage controller. +  * Clean up immersion ​objectives 
-  * Turn off the shutter ​controller. +Else: 
-  * Turn off the microscope. +  * Clean up immersion objectives 
-  * If there'​s __another user__ for this microscope in the __next hour__ leave the mercury __lamp power source on, else turn it off__.  +  * Shutdown the computer 
-  * Be extra careful in weekends and at the end of the day to make sure that the mercury ​lamp is not going to be turned on for an excessive time. +  * Turn off the camera 
 +  * Turn off the Prior stage controller 
 +  * Turn off the microscope 
 +  * Turn off the fluorescent ​lamp
  
 ---- ----
 [[resources|Back to the Resources page]] [[resources|Back to the Resources page]]
zeiss_axiovert_200m.txt · Last modified: 2024/02/12 22:50 by bioimaging