 ===== Microscope overview ===== ===== Microscope overview =====
  
-The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Roper Scientific ​Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer|Zeiss Cell Observer]] with Definite Focus. If don't want to use deconvolution,​ check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]][[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.+The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Photometrics ​Coolsnap HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If you are performing long time-lapse experiments in live samples (aqueous media) and need hardware focus control, check the [[zeiss_cell_observer|Zeiss Cell Observer]] with Definite Focus. If don't want to use deconvolution,​ check out one of the confocal systems such as the point scanners ​[[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or the spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead
 + 
 +  * **Microscope**:​ Zeiss Axiovert 200 
 +  * **Camera**: Photometrics Coolsnap HQ CCD 
 + 
 +{{warning.jpg?​20|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
  
 ===== Booking Rules ===== ===== Booking Rules =====
Line 41: Line 46:
   - The above rules do not apply for sessions booked on the very same day or **24 hours ahead**   - The above rules do not apply for sessions booked on the very same day or **24 hours ahead**
   - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**.   - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**.
-  - Users must indicate if they will use the incubator in the booking Description field (write down 37C INCUBATOR) 
  
 ===== System components ===== ===== System components =====
Line 94: Line 98:
 {{ax_cam_on.jpg?​100|}} {{ax_cam_on.jpg?​100|}}
   * Turn the computer on.   * Turn the computer on.
-  * Login to the computer (each group has it's own area and login).+  * Login to the computer (Axiovert 200M user).
   * Start the Metamorph software.   * Start the Metamorph software.
   * If you need temperature control, turn on the control box   * If you need temperature control, turn on the control box