User Tools

Site Tools


zeiss_axiovert_200m

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
zeiss_axiovert_200m [2016/04/06 00:35]
bioimaging
zeiss_axiovert_200m [2024/02/12 22:50]
bioimaging
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=axiovert_200m_name.jpg">+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_name_new.png">
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki.jpg" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_2022.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_2022.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_map.jpg">​Room P2-A-22</a> (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif" width=15> ​47217) <br>  +<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_map_new_p2a24.png">​Room P2-A-24</a> (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png" width=15> ​47219) <br>  
-<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​+<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​
 <​b>​Model</​b>:​ Axiovert 200M<​br>​ <​b>​Model</​b>:​ Axiovert 200M<​br>​
-<​b>​Software</​b>:​ Metamorph 7.7.9.0<​br>​+<​b>​Nickname</​b>:​ "​Axiovert"<​br>​ 
 +<​b>​Software</​b>:​ Metamorph 7.8.0.0<​br>​
 <​b>​Year</​b>:​ 2003 <br> <​b>​Year</​b>:​ 2003 <br>
 <​b>​SN</​b>:​ ZCA522000494<​br>​ <​b>​SN</​b>:​ ZCA522000494<​br>​
 +&nbsp <br>
 +Data will be deleted after: <b>1 month</​b>​
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=AXIOVERT&​rid=3"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​ 
- <​br> ​ 
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​
  <​br>​  <​br>​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Axiovert 200M Usage Statistics</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Axiovert 200M Usage Statistics</​a>​
- <​br>​ +</p>
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_repair"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=repair-icon.gif"​ width=16>​ Zeiss Axiovert 200M Repair History</​a>​ +
- </p>+
 </td> </td>
 </tr> </tr>
Line 28: Line 27:
 </​html>​ </​html>​
  
 +===== Microscope overview =====
 +
 +{{  :​widefield_lightpath.png?​0x300}}The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera ([[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics CoolSNAP HQ CCD]]) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. It is also equipped with a color camera ([[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]]) for acquisition of histological stains with tile and stitching imaging.
 +
 +  * **Microscope**:​ Zeiss Axiovert 200
 +  * **Monochrome Camera**: [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ CCD]]
 +  * **Color Camera**: [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]]
 +
 +{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
 +
 +===== System components =====
 +
 +==== Filtersets ====
 +
 +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^
 +|  1  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488001-9901-000&​o=|FS01]] ​ |  359-371 nm  |  395 nm  |  > 397 nm  |
 +|  2  |  Green BP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488010-9901-000&​o=|FS10]] ​ |  450-490 nm  |  510 nm  |  515-565 nm  |
 +|  3  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488020-9901-000&​o=|FS20]] ​ |  540-552 nm  |  560 nm  |  575-640 nm  |
 +|  4  |  Far Red  |  [[http://​www.semrock.com/​SetDetails.aspx?​id=2983|Cy5-4040C-000]] ​ |  608-648 nm  |  660 nm  |  672-712 nm  |
 +|  5  |  A  |  none  ||||
 +
 +**Upon request:**
 +
 +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^
 +|  2  |  Green LP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488009-9901-000&​o=|FS09]] ​ |  450-490 nm  |  510 nm  |  > 515 nm  |
 +
 +==== Objectives ====
 +^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color) ​ 10 μm =  ^  Reference ​ ^
 +|  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9900-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9900-000]] ​ |
 +|  20x  |  EC Plan-Neofluar ​ |  Air  |  0.50  |  2.00  |  0.48  |  21 pixels ​ |  46.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440340-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5|440340-9904-000]] ​ |
 +|  40x  |  EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440350-9903-000/​Objective-EC-Plan-Neofluar-40x-0.75|440350-9903-000]] ​ |
 +|  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |
 +|  100x  |  α Plan-Apochromat DIC  |  Oil  |  1.46  |  0.11  |  0.09  |  105 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420792-9800-000/​Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27|420792-9800-000]] ​ |
 +
 +
 +**Upon request:**
 +^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^  Reference ​ ^
 +|  1.25x  |  EC Epiplan-Neofluar ​ |  Air  |  0.035  |  4  |  7.58  |  1.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​422310-9900-000/​Objective-EC-Epiplan-Neofluar-1.25x-0.03-M27|422310-9900-000]] ​ |
 +|  5x  |  EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.5  |  2.00  |  5 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ |
 +|  40x  |  Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  0.24  |  41 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ |
 +|  63x  |  Plan-Apochromat Ph3  |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420781-9910-000/​Objective-Plan-Apochromat-63-1.4-Oil-Ph3-M27|420781-9910-000]] ​ |
 +
 +*** pixel sizes for binning = 1**
 +
 +==== Cameras ====
 +^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^
 +|  [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ]]  |  CCD  |  1392 x 1040  |  6.45 x 6.45  |
 +|  [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]] ​ |  color CCD  |  2560 × 1920  |  3.4 x 3.4  |
 +
 +==== Stage ====
 +For automated acquisition of 96 well plates use:
 +X = -9014 μm
 +Y = -8995 μm
 +
 +===== System Turn On Procedures =====
 +  * Turn on the fluorescent light power source (if used)
 +{{halide_710.jpg?​80|}}
 +  * Turn on the Prior stage controller ​
 +{{ax_prior_on.jpg?​100|}}
 +  * Turn on the microscope
 +{{ax_mic_on.jpg?​100|}}
 +  * Turn on the CCD camera
 +{{ax_cam_on.jpg?​100|}}
 +  * Turn on the computer
 +  * Log in to Windows (Bioimaging User)
 +  * Start the Metamorph software
 +  * If the software doesn'​t detect the camera, power cycle the camera and try again
 +===== Microscope Turn Off procedures =====
 +
 +If there is another user for this microscope in the __next hour__:
 +  * Leave the fluorescent lamp on (if used)
 +  * Clean up immersion objectives
 +Else:
 +  * Clean up immersion objectives
 +  * Shutdown the computer
 +  * Turn off the camera
 +  * Turn off the Prior stage controller
 +  * Turn off the microscope
 +  * Turn off the fluorescent lamp (if used)
 +
 +----
 +[[resources|Back to the Equipment page]]