User Tools

Site Tools


zeiss_axiovert_200m

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
zeiss_axiovert_200m [2016/04/06 00:35]
bioimaging
zeiss_axiovert_200m [2024/01/28 13:34]
bioimaging
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=axiovert_200m_name.jpg">+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_name_new.png">
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki.jpg"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki.jpg" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_2022.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_wiki_2022.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_map.jpg">​Room P2-A-22</a> (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=telephone_icon.gif" width=15> ​47217) <br>  +<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axiovert_200m_map_new_p2a24.png">​Room P2-A-24</a> (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png" width=15> ​47219) <br>  
-<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​Carl Zeiss MicroImaging</​a><​br>​+<​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​
 <​b>​Model</​b>:​ Axiovert 200M<​br>​ <​b>​Model</​b>:​ Axiovert 200M<​br>​
 +<​b>​Nickname</​b>:​ "​Axiovert"<​br>​
 <​b>​Software</​b>:​ Metamorph 7.7.9.0<​br>​ <​b>​Software</​b>:​ Metamorph 7.7.9.0<​br>​
 <​b>​Year</​b>:​ 2003 <br> <​b>​Year</​b>:​ 2003 <br>
 <​b>​SN</​b>:​ ZCA522000494<​br>​ <​b>​SN</​b>:​ ZCA522000494<​br>​
 +&nbsp <br>
 +Data will be deleted after: <b>1 month</​b>​
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​month.php?​user=AXIOVERT&​rid=3"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axiovert 200M Booking</​a>​ 
- <​br> ​ 
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert200m_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axiovert 200M Quality Control</​a>​
  <​br>​  <​br>​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Axiovert 200M Usage Statistics</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Axiovert 200M Usage Statistics</​a>​
- <​br>​ +</p>
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axiovert_200m_repair"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=repair-icon.gif"​ width=16>​ Zeiss Axiovert 200M Repair History</​a>​ +
- </p>+
 </td> </td>
 </tr> </tr>
Line 28: Line 27:
 </​html>​ </​html>​
  
 +===== Microscope overview =====
 +
 +{{  :​widefield_lightpath.png?​0x300}}The Zeiss Axiovert 200M is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. Using the Metamorph software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled CCD camera (Photometrics CoolSNAP HQ CCD) allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples.
 +
 +  * **Microscope**:​ Zeiss Axiovert 200
 +  * **Monochrome Camera**: [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ CCD]]
 +  * **Color Camera**: [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]]
 +
 +{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
 +
 +===== System components =====
 +
 +==== Filtersets ====
 +
 +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^
 +|  1  |  Blue  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488001-9901-000&​o=|FS01]] ​ |  359-371 nm  |  395 nm  |  > 397 nm  |
 +|  2  |  Green BP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488010-9901-000&​o=|FS10]] ​ |  450-490 nm  |  510 nm  |  515-565 nm  |
 +|  3  |  Red  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488020-9901-000&​o=|FS20]] ​ |  540-552 nm  |  560 nm  |  575-640 nm  |
 +|  4  |  Far Red  |  [[http://​www.semrock.com/​SetDetails.aspx?​id=2983|Cy5-4040C-000]] ​ |  608-648 nm  |  660 nm  |  672-712 nm  |
 +|  5  |  A  |  none  ||||
 +
 +**Upon request:**
 +
 +^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^
 +|  2  |  Green LP  |  [[https://​www.micro-shop.zeiss.com/?​s=163176628fcf844&​l=en&​p=us&​f=f&​a=v&​b=f&​id=488009-9901-000&​o=|FS09]] ​ |  450-490 nm  |  510 nm  |  > 515 nm  |
 +
 +==== Objectives ====
 +^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^ (color) ​ 10 μm =  ^  Reference ​ ^
 +|  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  1.00  |  10 pixels ​ |  23.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9900-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9900-000]] ​ |
 +|  20x  |  EC Plan-Neofluar ​ |  Air  |  0.50  |  2.00  |  0.48  |  21 pixels ​ |  46.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440340-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5|440340-9904-000]] ​ |
 +|  40x  |  EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  0.24  |  41 pixels ​ |  93.7 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440350-9903-000/​Objective-EC-Plan-Neofluar-40x-0.75|440350-9903-000]] ​ |
 +|  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  0.15  |  65 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |
 +|  100x  |  α Plan-Apochromat DIC  |  Oil  |  1.46  |  0.11  |  0.09  |  105 pixels ​ |  -  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420792-9800-000/​Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27|420792-9800-000]] ​ |
 +
 +
 +**Upon request:**
 +^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  pixel size* (μm)  ^  10 μm =  ^  Reference ​ ^
 +|  1.25x  |  EC Epiplan-Neofluar ​ |  Air  |  0.035  |  4  |  7.58  |  1.3 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​422310-9900-000/​Objective-EC-Epiplan-Neofluar-1.25x-0.03-M27|422310-9900-000]] ​ |
 +|  5x  |  EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.5  |  2.00  |  5 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ |
 +|  40x  |  Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  0.24  |  41 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ |
 +|  63x  |  Plan-Apochromat Ph3  |  Oil  |  1.4  |  0.19  |  0.15  |  65 pixels ​ |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420781-9910-000/​Objective-Plan-Apochromat-63-1.4-Oil-Ph3-M27|420781-9910-000]] ​ |
 +
 +*** pixel sizes for binning = 1**
 +
 +==== Cameras ====
 +^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^
 +|  [[https://​labs.pbrc.edu/​cellbiology/​documents/​CoolSNAPHQ.pdf|Photometrics Coolsnap HQ]]  |  CCD  |  1392 x 1040  |  6.45 x 6.45  |
 +|  [[https://​www.leica-microsystems.com/​products/​microscope-cameras/​p/​leica-dfc450-c/​|Leica DFC450]] ​ |  color CCD  |  2560 × 1920  |  3.4 x 3.4  |
 +
 +==== Stage ====
 +For automated acquisition of 96 well plates use:
 +X = -9014 μm
 +Y = -8995 μm
 +
 +===== System Turn On Procedures =====
 +  * Turn on the fluorescent light power source (if used)
 +{{halide_710.jpg?​80|}}
 +  * Turn on the Prior stage controller ​
 +{{ax_prior_on.jpg?​100|}}
 +  * Turn on the microscope
 +{{ax_mic_on.jpg?​100|}}
 +  * Turn on the CCD camera
 +{{ax_cam_on.jpg?​100|}}
 +  * Turn on the computer
 +  * Log in to Windows (Bioimaging User)
 +  * Start the Metamorph software
 +  * If the software doesn'​t detect the camera, power cycle the camera and try again
 +===== Microscope Turn Off procedures =====
 +
 +If there is another user for this microscope in the __next hour__:
 +  * Leave the fluorescent lamp on (if used)
 +  * Clean up immersion objectives
 +Else:
 +  * Clean up immersion objectives
 +  * Shutdown the computer
 +  * Turn off the camera
 +  * Turn off the Prior stage controller
 +  * Turn off the microscope
 +  * Turn off the fluorescent lamp (if used)
 +
 +----
 +[[resources|Back to the Equipment page]]
zeiss_axiovert_200m.txt · Last modified: 2024/02/12 22:50 by bioimaging