This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
zeiss_axio_observer [2016/06/29 11:08] bioimaging [Booking Rules] |
zeiss_axio_observer [2017/04/13 18:31] bioimaging removed |
||
---|---|---|---|
Line 67: | Line 67: | ||
| 40x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440451-9903-000|Plan-Neofluar Ph3]] | Oil | 1.30 | 0.20 | | | 40x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440451-9903-000|Plan-Neofluar Ph3]] | Oil | 1.30 | 0.20 | | ||
| 63x | [[https://www.micro-shop.zeiss.com/?s=571858182d6d9d&l=en&p=uk&f=o&a=v&m=s&id=420781-9910-000|Plan-Apochromat Ph3]] | Oil | 1.4 | 0.19 | | | 63x | [[https://www.micro-shop.zeiss.com/?s=571858182d6d9d&l=en&p=uk&f=o&a=v&m=s&id=420781-9910-000|Plan-Apochromat Ph3]] | Oil | 1.4 | 0.19 | | ||
- | | 100x | [[https://www.micro-shop.zeiss.com/?s=7138707e1a1de&l=en&p=uk&f=o&a=v&m=s&id=420792-9800-000|alpha Plan-Apochromat]] | Oil | 1.46 | 0.11 | | + | | 100x | [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440782-9902-000|Plan-Apochromat]] | Oil | 1.40 | 0.17 | |
===== System Turn On Procedures ===== | ===== System Turn On Procedures ===== | ||
* Turn on the HXP 120 fluorescence light. | * Turn on the HXP 120 fluorescence light. | ||
- | {{zeiss_cell_observer_wf_hxp.jpg?120|}} | + | {{zeiss_axio_observer_hxp.jpg?120|}} |
* Turn on the Temperature and CO2 controller (if you need them). | * Turn on the Temperature and CO2 controller (if you need them). | ||
- | {{zeiss_cell_observer_wf_temp.jpg?80|}} | + | {{zeiss_axio_observer_temp.jpg?80|}} |
* If you need CO2, open the valve | * If you need CO2, open the valve | ||
- | {{zeiss_cell_observer_wf_co2.jpg?80|}} | + | {{zeiss_axio_observer_co2.jpg?80|}} |
* Turn on the Motorized Stage controller (A) | * Turn on the Motorized Stage controller (A) | ||
- | {{zeiss_cell_observer_wf_a.jpg?height=150|}} | + | {{zeiss_axio_observer_a.jpg?height=150|}} |
* Turn on the Definite Focus controller (if you are going to use it) | * Turn on the Definite Focus controller (if you are going to use it) | ||
- | {{zeiss_cell_observer_wf_df.jpg?height=150|}} | + | {{zeiss_axio_observer_df.jpg?height=150|}} |
* Turn on the Microscope power supply (B) | * Turn on the Microscope power supply (B) | ||
- | {{zeiss_cell_observer_wf_b.jpg?height=150|}} | + | {{zeiss_axio_observer_b.jpg?height=150|}} |
* Turn on the computer | * Turn on the computer | ||
* Log in Windows with your lab user account (each lab has it's own area and login). | * Log in Windows with your lab user account (each lab has it's own area and login). |