User Tools

Site Tools


zeiss_axio_observer

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
zeiss_axio_observer [2016/06/29 11:05]
bioimaging created
zeiss_axio_observer [2017/04/13 18:31]
bioimaging removed
Line 16: Line 16:
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​125"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Cell Observer ​WF Booking</​a>​+&rarr; <a href="​https://​imm.medicina.ulisboa.pt/​intranet/​booking/​125"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Zeiss Axio Observer Booking</​a>​
  <​br> ​  <​br> ​
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_cell_observer_wf_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Cell Observer ​WF Quality Control</​a>​+&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axio_observer_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png"​ width=18>​ Zeiss Axio Observer Quality Control</​a>​
  <​br>​  <​br>​
-&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_cell_observer_wf_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Cell Observer ​WF Usage Statistics</​a>​+&rarr; <a href="/​facility/​bioimaging/​doku.php?​id=zeiss_axio_observer_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Zeiss Axio Observer Usage Statistics</​a>​
  </​p>​  </​p>​
 </td> </td>
Line 28: Line 28:
  
 ===== Microscope overview ===== ===== Microscope overview =====
-The Zeiss Cell Observer ​WF is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a large cage incubator and a small stage incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN 2 software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled Axiocam 506m camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If don't want to use deconvolution,​ check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]], the [[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.+The Zeiss Axio Observer is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a large cage incubator and a small stage incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN 2 software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled Axiocam 506m camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If don't want to use deconvolution,​ check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]], the [[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead.
  
 ===== Booking Rules ===== ===== Booking Rules =====
-The Zeiss Cell Observer ​WF booking is divided in three daily slots:+The Zeiss Axio Observer booking is divided in three daily slots:
 |  9:00 to 13:00  |  13:00 to 17:00  |  17:00 to 21:00  | |  9:00 to 13:00  |  13:00 to 17:00  |  17:00 to 21:00  |
  
Line 39: Line 39:
   - The above rules do not apply for sessions booked on the very same day or **24 hours ahead**   - The above rules do not apply for sessions booked on the very same day or **24 hours ahead**
   - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**.   - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**.
-  - Users must indicate which lasers they are going to use in the booking Description field 
   - Users must indicate if they will use the incubator in the booking Description field (write down 37C INCUBATOR)   - Users must indicate if they will use the incubator in the booking Description field (write down 37C INCUBATOR)
-  - Users must write their internal extension phone number in the booking Description field 
- 
 ===== System components ===== ===== System components =====
  
Line 70: Line 67:
 |  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar Ph3]]  |  Oil  |  1.30  |  0.20  | |  40x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440451-9903-000|Plan-Neofluar Ph3]]  |  Oil  |  1.30  |  0.20  |
 |  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat Ph3]]  |  Oil  |  1.4  |  0.19  | |  63x  |  [[https://​www.micro-shop.zeiss.com/?​s=571858182d6d9d&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420781-9910-000|Plan-Apochromat Ph3]]  |  Oil  |  1.4  |  0.19  |
-|  100x  |  [[https://​www.micro-shop.zeiss.com/?​s=7138707e1a1de&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=420792-9800-000|alpha Plan-Apochromat]] ​ |  Oil  |  1.46  ​| ​ 0.11  |+|  100x  |  [[https://​www.micro-shop.zeiss.com/?​s=3407786617d462&​l=en&​p=uk&​f=o&​a=v&​m=s&​id=440782-9902-000|Plan-Apochromat]] ​ |  Oil  |  1.40  ​| ​ 0.17  |
  
 ===== System Turn On Procedures ===== ===== System Turn On Procedures =====
   * Turn on the HXP 120 fluorescence light.   * Turn on the HXP 120 fluorescence light.
-{{zeiss_cell_observer_wf_hxp.jpg?120|}}+{{zeiss_axio_observer_hxp.jpg?120|}}
   * Turn on the Temperature and CO2 controller (if you need them).   * Turn on the Temperature and CO2 controller (if you need them).
-{{zeiss_cell_observer_wf_temp.jpg?80|}}+{{zeiss_axio_observer_temp.jpg?80|}}
   * If you need CO2, open the valve   * If you need CO2, open the valve
-{{zeiss_cell_observer_wf_co2.jpg?80|}}+{{zeiss_axio_observer_co2.jpg?80|}}
   * Turn on the Motorized Stage controller (A)   * Turn on the Motorized Stage controller (A)
-{{zeiss_cell_observer_wf_a.jpg?​height=150|}}+{{zeiss_axio_observer_a.jpg?​height=150|}}
   * Turn on the Definite Focus controller (if you are going to use it)   * Turn on the Definite Focus controller (if you are going to use it)
-{{zeiss_cell_observer_wf_df.jpg?​height=150|}}+{{zeiss_axio_observer_df.jpg?​height=150|}}
   * Turn on the Microscope power supply (B)   * Turn on the Microscope power supply (B)
-{{zeiss_cell_observer_wf_b.jpg?​height=150|}}+{{zeiss_axio_observer_b.jpg?​height=150|}}
   * Turn on the computer   * Turn on the computer
   * Log in Windows with your lab user account (each lab has it's own area and login).   * Log in Windows with your lab user account (each lab has it's own area and login).