nikon_eclipse_ti [2020/06/01 19:25]
bioimaging
nikon_eclipse_ti [2020/07/15 12:06]
bioimaging [Objectives]
Line 47: Line 47:
  
 ==== Objectives ==== ==== Objectives ====
-^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ +^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ​^ ​ pixel size* (μm)  ^  10 μm =  ​^ ​ Reference ​ ^ 
-|  10x  |  CFI Plan Fluor DLL Ph1  |  Air  |  0.30  |  16.00  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1835|MRH10101]] ​ | +|  10x  |  CFI Plan Fluor DLL Ph1  |  Air  |  0.30  |  16.00  |  ​0.454  |  22 pixels ​ |   [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1835|MRH10101]] ​ | 
-|  40x  |  CFI S Plan Fluor ELWD ADM Ph2  |  Air  |  0.60  |  2.80 - 3.60  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1814|MRH48430]] ​ | +|  40x  |  CFI S Plan Fluor ELWD ADM Ph2  |  Air  |  0.60  |  2.80 - 3.60  ​| ​ 0.115  |  86 pixels ​ ​| ​ [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1814|MRH48430]] ​ | 
-|  40x  |  ​CFI Plan Apo DM Ph3  |  ​Water  ​| ​ 1.00  |  0.16  |    |+|  40x  |  Plan Apo DM Ph3  |  ​Oil  ​| ​ 1.00  |  0.16  |   0.113  |  88 pixels ​ |  ​|
  
 **Upon request:** **Upon request:**
-^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ +^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ​^ ​ pixel size* (μm)  ^  10 μm =  ​^ ​ Reference ​ ^ 
-|  40x  |  ​CFI S Plan Fluor ELWD ADL Ph2  |  Air  |  0.60  |  2.70 - 3.70  |    +|  40x  |  Plan Fluor ELWD ADL Ph2  |  Air  |  0.60  |  2.70 - 3.70  |  ​0.113 ​ |  88 pixels ​ |  ​
-|  ​100x  ​| ​ CFI Plan  |  ​Water  ​|  ​1.10  ​|  ​2.50  ​| ​ [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1956|MRL07920]]  |+|  ​20x  ​| ​ CFI Plan Fluor ELWD ADM Ph1  ​|  ​Air  ​|  ​0.45  ​|  ​6.90 - 8.20  |  0.227  |  44 pixels ​ ​| ​ [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1813|MRH48230]]  |
  
 +*** pixel sizes for binning = 1**
 ==== Camera ==== ==== Camera ====
 ^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^ ^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^