User Tools

Site Tools


nikon_eclipse_ti

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
nikon_eclipse_ti [2020/03/01 18:05]
bioimaging [Filtersets]
nikon_eclipse_ti [2024/02/12 20:40]
bioimaging [Microscope overview]
Line 4: Line 4:
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_wiki_new.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_wiki_new.png" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_wiki_2022.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_wiki_2022.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_map_new.png">​Room ​P3-A-5</a> <​br> ​+<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=nikon_eclipse_ti_map_new_p2a24.png">​Room ​P2-A-24</​a> ​(<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) ​<​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​https://​www.microscope.healthcare.nikon.com/​en_EU/"​ target="​_blank">​Nikon Instruments</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​https://​www.microscope.healthcare.nikon.com/​en_EU/"​ target="​_blank">​Nikon Instruments</​a><​br>​
 <​b>​Model</​b>:​ Eclipse Ti<​br>​ <​b>​Model</​b>:​ Eclipse Ti<​br>​
 <​b>​Nickname</​b>:​ "​006"<​br>​ <​b>​Nickname</​b>:​ "​006"<​br>​
-<​b>​Software</​b>: ​Metamorph / NIS-Elements AR 5.11.01<​br>​+<​b>​Software</​b>:​ NIS-Elements AR 5.11.01<​br>​
 <​b>​Year</​b>:​ 2010 <br> <​b>​Year</​b>:​ 2010 <br>
 <​b>​SN</​b>:​ 602805 <br> <​b>​SN</​b>:​ 602805 <br>
 &nbsp <br> &nbsp <br>
 +Data will be deleted after: <b>3 months</​b>​
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
-&rarr; <a href="https://imm.medicina.ulisboa.pt/intranet/​booking/​163"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=date.png"> ​ Nikon Eclipse Ti Booking</a>+&rarr; <a href="/​facility/bioimaging/doku.php?​id=nikon_eclipse_ti_quality"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=list-icon.png" ​width=18> Nikon Eclipse Ti Quality Control</a>
  <​br> ​  <​br> ​
 &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=nikon_eclipse_ti_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Nikon Eclipse Ti Usage Statistics</​a>​ &rarr; <a href="/​facility/​bioimaging/​doku.php?​id=nikon_eclipse_ti_usage"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=chart_line.png"> ​ Nikon Eclipse Ti Usage Statistics</​a>​
Line 27: Line 28:
  
 ===== Microscope overview ===== ===== Microscope overview =====
-{{  :​widefield_lightpath.png?​0x300}}The Nikon Eclipse Ti is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supply and with Perfect Focus System for hardware focus control during long time-lapse acquisitions. Using either Metamorph or Nikon Elements software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. It is equipped with a Retiga R6 monochrome ​CCD camera ​that allows for a large field of view, ideal for time-lapse and tile-and-stitch microscopy. You can perform Z-stack acquisition and use [[https://​huygens.i3s.up.pt/​login.php|PPBI Huygens RM]] [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server to significantly improve image resolution even in thick samples. If don't want to use deconvolution,​ check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]].+{{  :​widefield_lightpath.png?​0x300}}The Nikon Eclipse Ti is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging applications. It is equipped with a small stage incubator for temperature control and CO2 supplyand with Perfect Focus System for hardware focus control during long time-lapse acquisitions. Using NIS-Elements software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. It is equipped with an Andor Neo 5.5 monochrome ​cooled sCMOS camera. ​
  
   * **Microscope**:​ [[https://​www.microscope.healthcare.nikon.com/​en_EU/​products/​inverted-microscopes/​eclipse-ti-series|Nikon Eclipse Ti]]   * **Microscope**:​ [[https://​www.microscope.healthcare.nikon.com/​en_EU/​products/​inverted-microscopes/​eclipse-ti-series|Nikon Eclipse Ti]]
-  * **Camera**: [[https://​www.qimaging.com/retiga-r6|Teledyne QImaging Retiga R6 mono CCD]]+  * **Camera**: ​[[https://​andor.oxinst.com/​products/​scmos-camera-series/​neo-5-5-scmos|Andor Neo 5.5 sCMOS]] 
 + 
 +This microscope is also equipped with a [[https://​www.ionoptix.com/products/​systems/​calcium-and-contractility-system/​|Ionoptix Calcium and Contractility system]] for high-speed simultaneous acquisition of Fura-2 fluorescence with video-based cell length measurement to study myocyte function, contracting spontaneously or with field stimulation. 
 + 
 +{{::​ionoptix_realtime-acquisition-cell-length-600x500.jpg?​200 ​ |}} 
 +  * **High-speed contractility camera**: [[https://​www.ionoptix.com/​products/​components/​sensors/​myocam-s3/​|MyoCam-S3]] 
 +  * **Electrical Field Stimulator**:​ [[https://​www.ionoptix.com/​products/​components/​stimulators/​myopacer-cell-stimulator/​|MyoPacer]] 
 +  * **LED Light Source**: [[https://​www.ionoptix.com/​products/​components/​light-sources/​led-light-source/​|UV LEDs for Fura-2 excitation]] 
 +  * **High-speed PMT**: [[https://​www.ionoptix.com/​products/​components/​sensors/​pmt-sub-system/​|PMT400]] for photon counting at 1kHz 
 +  * **Software**:​ [[https://​www.ionoptix.com/​products/​software/​ionwizard-core-and-analysis/​|IonWizard]] 7.7.3.180
  
 {{:​warning.png?​25|}} Data files older than **3 months** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link. {{:​warning.png?​25|}} Data files older than **3 months** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.
Line 36: Line 46:
 ===== System components ===== ===== System components =====
  
-==== Filtersets ====+==== Filtersets ​Turret 1 (top) ====
  
 ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^ ^  Position ​ ^  Filterset ​ ^  Reference ​ ^  Excitation ​ ^  Dichroic ​ ^  Emission ​ ^
Line 45: Line 55:
 |  5  |  Cy5  |  2SK4CY50 ​ |  608-648 nm  |  660 nm  |  672-712 nm  | |  5  |  Cy5  |  2SK4CY50 ​ |  608-648 nm  |  660 nm  |  672-712 nm  |
 |  6  |  Empty  ||||| |  6  |  Empty  |||||
 +
 +==== Filtersets Turret 2 (bottom) ====
 +
 +^  Position ​ ^  Filterset ​ ^
 +|  1  |  Empty  |
 +|  2  |  Empty  |
 +|  3  |  Empty  |
 +|  4  |  Empty  |
 +|  5  |  Empty  |
 +|  6  |  Fura-2 ​ |
  
 ==== Objectives ==== ==== Objectives ====
 ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
-|  10x  |  CFI Plan Fluor DLL Ph1  |  Air  |  0.30  |  16.00  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1835|MRH10101]] ​ |+|  10x  |  CFI Plan Fluor DLL Ph1  |  Air  |  0.30  |  16.00  |   ​[[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1835|MRH10101]]  | 
 +|  20x  |  CFI S Plan Fluor ELWD ADM Ph1  |  Air  |  0.45  |  6.90 - 8.20  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1813|MRH48230]] ​ | 
 +|  40x  |  CFI CFI Plan Apochromat Lambda D  |  Air  |  0.95  |  0.21  |  [[https://​www.microscope.healthcare.nikon.com/​products/​optics/​selector/​comparison/​-179806|MRH70470]]  |
 |  40x  |  CFI S Plan Fluor ELWD ADM Ph2  |  Air  |  0.60  |  2.80 - 3.60  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1814|MRH48430]] ​ | |  40x  |  CFI S Plan Fluor ELWD ADM Ph2  |  Air  |  0.60  |  2.80 - 3.60  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1814|MRH48430]] ​ |
-|  ​40x  ​|  ​CFI Plan Apo DM Ph3  |  ​Water  ​| ​ 1.00  ​| ​ 0.16  ​| ​   |+|  ​60x  ​| ​ Plan Apo DM Ph3  |  ​Oil  ​| ​ 1.40  ​| ​ 0.13  ​| ​ | 
 +|  100x  |  Plan Apo DM Ph3  |  Oil  |  1.40  |  0.13  |  ​|
  
 **Upon request:** **Upon request:**
 ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^ ^  Magnification ​ ^  Model  ^  Immersion ​ ^  NA  ^  WD (mm)  ^  Reference ​ ^
-|  40x  |  CFI S Plan Fluor ELWD ADL Ph2  |  Air  |  0.60  |  2.70 - 3.70  |    | 
 |  100x  |  CFI Plan  |  Water  |  1.10  |  2.50  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1956|MRL07920]] ​ | |  100x  |  CFI Plan  |  Water  |  1.10  |  2.50  |  [[https://​www.microscope.healthcare.nikon.com/​en_EU/​selectors/​objective-comparison/​-1956|MRL07920]] ​ |
- 
 ==== Camera ==== ==== Camera ====
 ^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^ ^  Model  ^  Type  ^  Frame Size  ^  Pixel Size (µm)  ^
-|  [[https://www.qimaging.com/retiga-r6|Retiga R6 mono CCD]]  |  CCD  |  ​2688 2200  ​|  ​4.54 4.54  |+|  [[https://andor.oxinst.com/products/​scmos-camera-series/​neo-5-5-scmos|Andor Neo 5.5 sCMOS]]  |  CCD  |  ​2560 2160  ​|  ​6.6. |
  
 ---- ----
-[[resources|Back to the Resources ​page]]+[[resources|Back to the Equipment ​page]]
nikon_eclipse_ti.txt · Last modified: 2024/02/12 22:47 by bioimaging