Previous revision
zeiss_lsm_980-32 [2024/07/16 23:44]
bioimaging [How to start your session]
zeiss_lsm_980-32 [2025/02/18 10:20] (current)
bioimaging [Microscope Turn Off Procedure (for complete shutdown)]
Line 1: Line 1:
 <​html>​ <​html>​
-<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_980-32_name.png">​+<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=lisbon_zeiss_lsm_980-32_with_airyscan_2_name_gimm_2024.png">​
 <table style="​border:​0px solid white;">​ <table style="​border:​0px solid white;">​
 <tr style="​border:​0px solid white;">​ <tr style="​border:​0px solid white;">​
 <td style="​border:​0px solid white;">​ <td style="​border:​0px solid white;">​
-<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_980-32_wiki.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_980-32_wiki.png" width=300></​a>​+<a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_980-32_wiki_2024.png"><​img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_980-32_wiki_2024.png" width=300></​a>​
 <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​ <td style="​border:​0px solid white;">​ <p style="​line-height:​1.8">​
-<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_980-32_map_2024.png">​Room P2-A-24</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) <​br> ​+<​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_lsm_980-32_map_2024.png">​[Lisbon] ​Room P2-A-24</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​
 <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​confocal-microscopes/​lsm-980-with-airyscan-2.html">​LSM 980 with Airyscan 2</​a><​br>​ <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​confocal-microscopes/​lsm-980-with-airyscan-2.html">​LSM 980 with Airyscan 2</​a><​br>​
 <​b>​Nickname</​b>:​ "​980-32"<​br>​ <​b>​Nickname</​b>:​ "​980-32"<​br>​
-<​b>​Software</​b>:​ ZEN 3.8 (blue edition)<br>+<​b>​Software</​b>:​ ZEN 3.9<br>
 <​b>​Year</​b>:​ 2024 <br> <​b>​Year</​b>:​ 2024 <br>
 <​b>​SN</​b>:​ 2842001157 <br> <​b>​SN</​b>:​ 2842001157 <br>
 &nbsp <br> &nbsp <br>
 Data will be deleted after: <b>1 month</​b>​ Data will be deleted after: <b>1 month</​b>​
-&nbsp <br> 
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
Line 29: Line 28:
 ===== Microscope overview ===== ===== Microscope overview =====
  
-{{  :​confocal_pinhole.png?​340}} The Zeiss LSM 980-32 with Airyscan 2 is a [[https://​www.youtube.com/​watch?​v=rTkjQ6Q0p5I|point scanning confocal microscope]] able to generate high-resolution three-dimensional images of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted microscope especially suitable for live cell imaging and photobleaching experiments,​ equipped with a dark large cage incubator and a stage top incubator for temperature control and CO2 supply, with Definite Focus.3 for hardware focus control during long time-lapse acquisitions,​ and with an [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research/​autoimmersion-module.html|autoimmersion module for water objectives]]. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions, using the Tiles Advanced Setup of ZEN blue. It is equipped with [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​ai-sample-finder.html|AI Sample Finder]] for automated sample placement, focus adjustment and identification of the relevant sample areas. Its [[http://​www.zeiss.com/​content/​dam/​Microscopy/​Products/​laser-scan/​LSM%20880/​zeiss-lsm880-airyscan-principle-672.jpg|Airyscan 2]] with 32 concentrically arranged GaAsP detection elements is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (120 nm laterally and 350 nm axially in SR mode, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=tUiEa7vcggQ|Multiplex Mode]], which enables parallel excitation and detection in 4Y or 8Y modes (speed improvement of 4x/8x maintaining Airyscan sensitivity). Its scanning unit further includes a [[https://​imm.medicina.ulisboa.pt/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=32-channel_quasar.png|32-channel GaAsP detector]] for simultaneous [[https://​zeiss-campus.magnet.fsu.edu/​articles/​spectralimaging/​introduction.html|spectral imaging and separation of fluorescent labels]] and two PMT detectors. It is equipped with lasers from violet to far red (405, 445, 488, 514, 561, 594 and 639 nm excitation wavelengths). Its[[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|LSM Plus deconvolution]] mode enhances signal-to-noise ratio by acting as a denoising step post image acquisition,​ allowing for high acquisition speed and low laser power. Using its [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|Airyscan Joint Deconvolution (jDCV)]] option, the resolution can be improved to 90 nm (XY) and 270 nm (Z). A dedicated workstation is also available for Direct Processing during acquisition.+{{  :​confocal_pinhole.png?​340}} The Zeiss LSM 980-32 with Airyscan 2 is a [[https://​www.youtube.com/​watch?​v=rTkjQ6Q0p5I|point scanning confocal microscope]] able to generate high-resolution three-dimensional images of thick specimens with high sensitivity,​ high speed and low photodamage. It is an inverted microscope especially suitable for live cell imaging and photobleaching experiments,​ equipped with a dark large cage incubator and a stage top incubator for temperature control and CO2 supply, with Definite Focus.3 for hardware focus control during long time-lapse acquisitions,​ and with an [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research/​autoimmersion-module.html|autoimmersion module for water objectives]]. The stage is motorized and furthermore equipped with a piezo for Z displacement so fast 4D imaging is possible in multiple stage positions, using the Tiles Advanced Setup of ZEN blue. It is equipped with [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​ai-sample-finder.html|AI Sample Finder]] for automated sample placement, focus adjustment and identification of the relevant sample areas. Its Airyscan 2 with 32 concentrically arranged GaAsP detection elements is able to collect all light from an Airy pattern simultaneously,​ allowing for increased resolution (120 nm laterally and 350 nm axially in SR mode, at 488 nm). It can also be used in [[https://​www.youtube.com/​watch?​v=tUiEa7vcggQ|Multiplex Mode]], which enables parallel excitation and detection in 4Y or 8Y modes (speed improvement of 4x/8x maintaining Airyscan sensitivity). Its scanning unit further includes a [[https://​imm.medicina.ulisboa.pt/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=32-channel_quasar.png|32-channel GaAsP detector]] for simultaneous [[https://​zeiss-campus.magnet.fsu.edu/​articles/​spectralimaging/​introduction.html|spectral imaging and separation of fluorescent labels]] and two PMT detectors. It is equipped with lasers from violet to far red (405, 445, 488, 514, 561, 594 and 639 nm excitation wavelengths). Its[[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|LSM Plus deconvolution]] mode enhances signal-to-noise ratio by acting as a denoising step post image acquisition,​ allowing for high acquisition speed and low laser power. Using its [[https://​www.zeiss.com/​microscopy/​en/​about-us/​newsroom/​press-releases/​2021/​zeiss-lsm-plus-and-zeiss-airyscan-joint-deconvolution.html|Airyscan Joint Deconvolution (jDCV)]] option, the resolution can be improved to 90 nm (XY) and 270 nm (Z). A dedicated workstation is also available for Direct Processing during acquisition.
  
   * **Microscope**:​ [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research.html|Zeiss Axio Observer]]   * **Microscope**:​ [[https://​www.zeiss.com/​microscopy/​en/​products/​light-microscopes/​widefield-microscopes/​axio-observer-for-life-science-research.html|Zeiss Axio Observer]]
Line 49: Line 48:
   * [[https://​www.youtube.com/​watch?​v=zA4xqq-EL9g|ZEISS Webinar: LSM 980 Airyscan 2 Multiplex mode]]   * [[https://​www.youtube.com/​watch?​v=zA4xqq-EL9g|ZEISS Webinar: LSM 980 Airyscan 2 Multiplex mode]]
  
-{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the iMM server using the desktop link.+{{:​warning.png?​25|}} Data files older than **1 month** will be automatically deleted on this system, please copy your data to the GIMM server using the desktop link.
  
 ===== Booking Rules ===== ===== Booking Rules =====
Line 89: Line 88:
 |  :::  |  :::  |  :::  |  540-570 nm  |  575 nm  |  580-605 nm  | |  :::  |  :::  |  :::  |  540-570 nm  |  575 nm  |  580-605 nm  |
 |  :::  |  :::  |  :::  |  615-648 nm  |  653 nm  |  659-759 nm  | |  :::  |  :::  |  :::  |  615-648 nm  |  653 nm  |  659-759 nm  |
 +
 +===== How to start your session =====
  
 The system should be always on, you only need to: The system should be always on, you only need to:
Line 94: Line 95:
   * Log into Windows with your Agendo credentials   * Log into Windows with your Agendo credentials
   * Start **ZEN**   * Start **ZEN**
 +
 ===== How to end your session ===== ===== How to end your session =====
  
Line 114: Line 116:
   * Turn on the ''​COMPONENTS''​ switch   * Turn on the ''​COMPONENTS''​ switch
 {{::​zeiss_lsm_980_components.png?​100|}} {{::​zeiss_lsm_980_components.png?​100|}}
 +  * Turn on the Laser key
   * Turn on the computer   * Turn on the computer
   * Log into Windows with your Agendo credentials   * Log into Windows with your Agendo credentials
Line 125: Line 128:
   * Exit the ZEN software   * Exit the ZEN software
   * Shutdown the computer   * Shutdown the computer
-  * Turn off the ''​COMPONENTS''​ switch ​(do not turn off the Laser key!)+  ​* Turn off the Laser key 
 +  ​* Turn off the ''​COMPONENTS''​ switch
   * Turn off the ''​MAIN SWITCH''​   * Turn off the ''​MAIN SWITCH''​
  
 ---- ----
 [[resources|Back to the Equipment page]] [[resources|Back to the Equipment page]]