zeiss_axioscan_7 [2025/04/01 15:19]
bioimaging
zeiss_axioscan_7 [2025/07/19 22:21] (current)
bioimaging
Line 10: Line 10:
 <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​imaging-systems/​axioscan-for-biology.html">​Axioscan 7</​a><​br>​ <​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​imaging-systems/​axioscan-for-biology.html">​Axioscan 7</​a><​br>​
 <​b>​Nickname</​b>:​ "​Axioscan"<​br>​ <​b>​Nickname</​b>:​ "​Axioscan"<​br>​
-<​b>​Software</​b>:​ ZEN 3.(ZEN Slidescan)<​br>​+<​b>​Software</​b>:​ ZEN 3.12 (ZEN Slidescan)<​br>​
 <​b>​Year</​b>:​ 2024 <br> <​b>​Year</​b>:​ 2024 <br>
 <​b>​SN</​b>:​ 4661000477<​br>​ <​b>​SN</​b>:​ 4661000477<​br>​
Line 60: Line 60:
  
  
-Check here an experimental design in [[https://​www.fpbase.org/​spectra/?​s=7754,​222,​223,​204,​205,306,307,2055,2057,2068,​262,​263,​$cf0_BP_425_30_90,​$cf1_BP_515_30_90,​$cf2_BP_683_45_90,$cf3_BP_593_25_90,​2059&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength | FPbase.org for a sample stained with DAPI+A488+A568+A647]]+Check here to check your experimental design in [[https://​www.fpbase.org/​spectra/?​s=7754,​222,​223,​204,​205,​2055,​2057,​262,​263,​2059,​2068,​306,​307,​$cf0_BP_425_30_90,​$cf1_BP_515_30_90,​$cf2_BP_593_25_90,$cf3_BP_683_45_90&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength | FPbase.org for a sample stained with DAPI+A488+A568+A647 ​(change at will!)]]
  
  
Line 78: Line 78:
  
   * Turn on the Axioscan 7   * Turn on the Axioscan 7
-  * Turn on the computer+  * Turn on the computer ​(if needed)
   * Login in to Windows with your Agendo credentials   * Login in to Windows with your Agendo credentials
   * Start the **ZEN** software   * Start the **ZEN** software
Line 85: Line 85:
 If there is another user for this microscope is the __next hour__: If there is another user for this microscope is the __next hour__:
   * Exit the ZEN software   * Exit the ZEN software
-  * Log off Windows+  * Log off the computer
 Else Else
   * Exit the ZEN software   * Exit the ZEN software
-  * Turn off the computer+  * Log off the computer
   * Turn off the Axioscan 7   * Turn off the Axioscan 7
  
 ---- ----
 [[resources|Back to the Equipment page]] [[resources|Back to the Equipment page]]