Line 8: Line 8:
 <​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axioscan_7_map_2024.png">​[Lisbon] Room P2-A-24</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) <​br> ​ <​b>​Location</​b>:​ <a href="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=zeiss_axioscan_7_map_2024.png">​[Lisbon] Room P2-A-24</​a>​ (<img src="/​facility/​bioimaging/​lib/​exe/​fetch.php?​media=phone_neg.png"​ width=15>​ 47219) <​br> ​
 <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​ <​b>​Manufacturer</​b>:​ <a href="​http://​www.zeiss.de/​micro"​ target="​_blank">​ZEISS Microscopy</​a><​br>​
-<​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​imaging-systems/​axioscan-for-biology.htm">​Axioscan 7</​a><​br>​+<​b>​Model</​b>:​ <a href="​https://​www.zeiss.com/​microscopy/​en/​products/​imaging-systems/​axioscan-for-biology.html">​Axioscan 7</​a><​br>​
 <​b>​Nickname</​b>:​ "​Axioscan"<​br>​ <​b>​Nickname</​b>:​ "​Axioscan"<​br>​
-<​b>​Software</​b>:​ ZEN 3.(ZEN Slidescan)<​br>​+<​b>​Software</​b>:​ ZEN 3.12 (ZEN Slidescan)<​br>​
 <​b>​Year</​b>:​ 2024 <br> <​b>​Year</​b>:​ 2024 <br>
 <​b>​SN</​b>:​ 4661000477<​br>​ <​b>​SN</​b>:​ 4661000477<​br>​
Line 58: Line 58:
 |  :::  |  :::  |  654 nm  |  660-705 nm  | |  :::  |  :::  |  654 nm  |  660-705 nm  |
 |  :::  |  :::  |  761 nm  |  769-807 nm  | |  :::  |  :::  |  761 nm  |  769-807 nm  |
 +
 +
 +Check here to check your experimental design in [[https://​www.fpbase.org/​spectra/?​s=7754,​222,​223,​204,​205,​2055,​2057,​262,​263,​2059,​2068,​306,​307,​$cf0_BP_425_30_90,​$cf1_BP_515_30_90,​$cf2_BP_593_25_90,​$cf3_BP_683_45_90&​showY=0&​showX=1&​showGrid=0&​areaFill=1&​logScale=0&​scaleEC=0&​scaleQY=0&​shareTooltip=1&​palette=wavelength | FPbase.org for a sample stained with DAPI+A488+A568+A647 (change at will!)]]
 +
  
 ==== Objectives ==== ==== Objectives ====
Line 74: Line 78:
  
   * Turn on the Axioscan 7   * Turn on the Axioscan 7
-  * Turn on the computer+  * Turn on the computer ​(if needed)
   * Login in to Windows with your Agendo credentials   * Login in to Windows with your Agendo credentials
   * Start the **ZEN** software   * Start the **ZEN** software
Line 81: Line 85:
 If there is another user for this microscope is the __next hour__: If there is another user for this microscope is the __next hour__:
   * Exit the ZEN software   * Exit the ZEN software
-  * Log off Windows+  * Log off the computer
 Else Else
   * Exit the ZEN software   * Exit the ZEN software
-  * Turn off the computer+  * Log off the computer
   * Turn off the Axioscan 7   * Turn off the Axioscan 7
  
 ---- ----
 [[resources|Back to the Equipment page]] [[resources|Back to the Equipment page]]
zeiss_axioscan_7.1736868810.txt.gz ยท Last modified: 2025/01/14 16:33 by bioimaging