User Tools

Site Tools


zeiss_axio_observer

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
zeiss_axio_observer [2016/09/27 14:30] – [Objectives] bioimagingzeiss_axio_observer [2017/04/13 17:31] (current) – removed bioimaging
Line 1: Line 1:
-<html> 
-<img src="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axio_observer_name.jpg"> 
-<table style="border:0px solid white;"> 
-<tr style="border:0px solid white;"> 
-<td style="border:0px solid white;"> 
-<a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axio_observer_wiki.jpg"><img src="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axio_observer_wiki.jpg" width=300></a> 
-<td style="border:0px solid white;"> <p style="line-height:1.8"> 
-<b>Location</b>: <a href="/facility/bioimaging/lib/exe/fetch.php?media=zeiss_axio_observer_map.jpg">Room P3-A-10</a> (<img src="/facility/bioimaging/lib/exe/fetch.php?media=telephone_icon.gif" width=15> 47311) <br>  
-<b>Manufacturer</b>: <a href="http://www.zeiss.de/micro" target="_blank">Carl Zeiss MicroImaging</a><br> 
-<b>Model</b>: Axio Observer<br> 
-<b>Software</b>: ZEN 2 (blue edition)<br> 
-<b>Year</b>: 2015 <br> 
-<b>SN</b>: 1026052056<br> 
-&nbsp <br> 
-&nbsp <br> 
-&nbsp <br> 
-&nbsp <br> 
-&rarr; <a href="https://imm.medicina.ulisboa.pt/intranet/booking/125"><img src="/facility/bioimaging/lib/exe/fetch.php?media=date.png">  Zeiss Axio Observer Booking</a> 
- <br>  
-&rarr; <a href="/facility/bioimaging/doku.php?id=zeiss_axio_observer_quality"><img src="/facility/bioimaging/lib/exe/fetch.php?media=list-icon.png" width=18> Zeiss Axio Observer Quality Control</a> 
- <br> 
-&rarr; <a href="/facility/bioimaging/doku.php?id=zeiss_axio_observer_usage"><img src="/facility/bioimaging/lib/exe/fetch.php?media=chart_line.png">  Zeiss Axio Observer Usage Statistics</a> 
- </p> 
-</td> 
-</tr> 
-</table> 
-</html> 
  
-===== Microscope overview ===== 
-The Zeiss Axio Observer is a fully motorized inverted //widefield fluorescence microscope// ideal for live-cell imaging applications. It is equipped with a large cage incubator and a small stage incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN 2 software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. Its sensitive cooled Axiocam 506m camera allows you to capture weak fluorescent signals and minimize photobleaching/photodamage in light sensitive samples. You can also perform Z-stack acquisition and use our [[http://micro.magnet.fsu.edu/primer/digitalimaging/deconvolution/deconvolutionhome.html|deconvolution]] server [[brainstorm|Brainstorm]] to significantly improve image resolution even in thick samples. If don't want to use deconvolution, check out one of the confocal systems such as the [[zeiss_lsm_710|Zeiss LSM 710]], the [[zeiss_lsm_880|Zeiss LSM 880]] or the [[3i_marianas_sdc|3i Marianas SDC]] spinning disk. If your personal computer cannot handle all the data you collected, check out the [[big_guy|Big Guy]] or [[colossus|Colossus]]. If you have FISH or other fixed fluorescence slides try the [[leica_dm5000b|Leica DM5000B]] instead. 
- 
-===== Booking Rules ===== 
-The Zeiss Axio Observer booking is divided in three daily slots: 
-|  9:00 to 13:00  |  13:00 to 17:00  |  17:00 to 21:00  | 
- 
-  - A **user** can book at maximum **2 sessions per week** 
-  - Each **session must fit inside one of the three daily slots** (i.e. a session booked from 11:00 to 14:00 counts as 2 sessions) 
-  - The above rules do not apply for **weekends** and for work days **before 9:00** and **after 21:00** 
-  - The above rules do not apply for sessions booked on the very same day or **24 hours ahead** 
-  - Exceptions to these rules require **approval from [[joserino@medicina.ulisboa.pt|José Rino]]**. 
-  - Users must indicate if they will use the incubator in the booking Description field (write down 37C INCUBATOR) 
-===== System components ===== 
- 
-==== Filtersets ==== 
- 
-^  Position  ^  Filterset  ^  Reference  ^  Excitation  ^  Emission  ^ 
-|  1  |  HE GFP  |  [[https://www.micro-shop.zeiss.com/?s=23108437692794b&l=en&p=us&f=f&a=v&b=f&id=489038-9901-000&o=|FS38HE]]  |  450-490 nm  |  500-550 nm  | 
-|  2  |  HE DsRed  |  [[https://www.micro-shop.zeiss.com/?s=23108437692794b&l=en&p=us&f=f&a=v&b=f&id=489043-9901-000&o=|FS43HE]]  |  538-562 nm  |  570-640 nm  | 
-|  3  |  DAPI  |  [[https://www.micro-shop.zeiss.com/?s=23108437692794b&l=en&p=us&f=f&a=v&b=f&id=488049-9901-000&o=|FS49]]  |  335-383 nm  |  420-470 nm  | 
-|  4  |  Cy5  |  [[https://www.micro-shop.zeiss.com/?s=23108437692794b&l=en&p=us&f=f&a=v&b=f&id=488050-9901-000&o=|FS50]]  |  625-655 nm  |  665-715 nm  | 
-|  5  |  none  |  none  |  none  |  none  | 
-|  6  |  none  |  none  |  none  |  none  | 
- 
-==== Objectives ==== 
-^  Magnification  ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^ 
-|  10x  |  [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=420340-9901-000|EC Plan-Neofluar]]  |  Dry  |  0.30  |  5.2  | 
-|  20x  |  [[https://www.micro-shop.zeiss.com/?s=2310860526ae9cb&l=en&p=uk&f=o&a=v&m=s&id=420650-9901-000|Plan-Apochromat]]  |  Dry  |  0.80  |  0.55  | 
-|  40x  |  [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440350-9903-000|EC Plan-NeoFluar]]  |  Dry  |  0.75  |  0.71  | 
-|  63x  |  [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=420782-9900-000|Plan-Apochromat]]  |  Oil  |  1.40  |  0.19  | 
- 
-**Upon request:** 
-^  Magnification  ^  Model  ^  Type  ^  NA  ^  WD (mm)  ^ 
-|  1.25x  |  [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=422310-9900-000|EC Epiplan-Neofluar]]  |  Dry  |  0.035  |  4  | 
-|  5x  |  [[https://www.micro-shop.zeiss.com/?s=571974962233f6&l=en&p=uk&f=o&a=v&m=s&id=420330-9901-000|EC Plan-NeoFluar]]  |  Dry  |  0.16  |  18.5  | 
-|  20x  |  [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440341-9904-000|EC Plan-Neofluar Ph 2]]  |  Dry  |  0.50  |  2  | 
-|  40x  |  [[https://www.micro-shop.zeiss.com/?s=129353259d52f12&l=en&p=uk&f=o&a=v&m=s&id=420660-9970-000|Plan-Apochromat]]  |  Dry  |  0.95  |  0.25  | 
-|  40x  |  [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440451-9903-000|Plan-Neofluar Ph3]]  |  Oil  |  1.30  |  0.20  | 
-|  63x  |  [[https://www.micro-shop.zeiss.com/?s=571858182d6d9d&l=en&p=uk&f=o&a=v&m=s&id=420781-9910-000|Plan-Apochromat Ph3]]  |  Oil  |  1.4  |  0.19  | 
-|  100x  |  [[https://www.micro-shop.zeiss.com/?s=3407786617d462&l=en&p=uk&f=o&a=v&m=s&id=440782-9902-000|Plan-Apochromat]]  |  Oil  |  1.40  |  0.17  | 
- 
-===== System Turn On Procedures ===== 
-  * Turn on the HXP 120 fluorescence light. 
-{{zeiss_axio_observer_hxp.jpg?120|}} 
-  * Turn on the Temperature and CO2 controller (if you need them). 
-{{zeiss_axio_observer_temp.jpg?80|}} 
-  * If you need CO2, open the valve 
-{{zeiss_axio_observer_co2.jpg?80|}} 
-  * Turn on the Motorized Stage controller (A) 
-{{zeiss_axio_observer_a.jpg?height=150|}} 
-  * Turn on the Definite Focus controller (if you are going to use it) 
-{{zeiss_axio_observer_df.jpg?height=150|}} 
-  * Turn on the Microscope power supply (B) 
-{{zeiss_axio_observer_b.jpg?height=150|}} 
-  * Turn on the computer 
-  * Log in Windows with your lab user account (each lab has it's own area and login). 
-  * Start the **ZEN 2** software 
- 
-===== Microscope Turn Off procedures ===== 
-  * Exit the **ZEN 2** software 
-  * Turn off the computer 
-  * If you used any __immersion oil in the objectives, clean them up__. 
-  * Turn off the microscope power supply (B) 
-  * Turn off the Definite Focus controller (if used) 
-  * Turn off the Motorized Stage controller (A) 
-  * Turn off the Temperature and CO2 controller (if used) 
-  * If there's __another user__ for this microscope in the __next hour__ leave the mercury __lamp power source on, else turn it off__.  
-  * Be extra careful in weekends and at the end of the day to make sure that the mercury lamp is not going to be turned on for an excessive time.  
- 
----- 
-[[resources|Back to the Resources page]] 
zeiss_axio_observer.1474983032.txt.gz · Last modified: by bioimaging