Line 64: Line 64:
 |  Ch2  (GaAsP) |  Green  |  570-620 nm  |  mCherry, Alexa568, Cy3  | |  Ch2  (GaAsP) |  Green  |  570-620 nm  |  mCherry, Alexa568, Cy3  |
 |  Ch3  (GaAsP) ​ |  Far Red  |  500-550 nm  |  GFP, Alexa488, FITC  | |  Ch3  (GaAsP) ​ |  Far Red  |  500-550 nm  |  GFP, Alexa488, FITC  |
-|  Ch4 (PMT)  |  Blue |  435-485 nm  |  DAPI, CFP or BS 2nd Harmonic ​ |+|  Ch4 (PMT) ​| ​ Blue  |  435-485 nm  |  DAPI*, CFP or SHG  | 
 + 
 +*Ch4 can be used either in fluorescence mode, or alternatively as a BF ("​DODT"​) channel or for SHG - ask staff 
 \\ \\
 **Upon request:** **Upon request:**
 \\ (requires changing filters and the dichroic beamsplitter) \\ (requires changing filters and the dichroic beamsplitter)
- 
-{{::​alternative_filtersetDiagram.png ​ |}} 
-\\ 
-^  Detector ​ ^  Filter ​ ^  Transmission ​ ^  Fluorochromes ​ ^ 
-|  Ch1  |  -  |  - nm  |  Cy5  | 
-|  Ch2  |  -  |  - nm  |  Alexa568 ​ | 
-|  Ch3  |  -  |  - nm  |  Alexa488 ​ | 
-|  Ch4  |  -  |  - nm  |  DAPI  | 
-|  DODT  |  -  |  - nm  |  BF  | 
-\\ 
  
 UNDER CONSTRUCTION!!! UNDER CONSTRUCTION!!!
Line 91: Line 84:
  
 ===== System turn Off procedures ===== ===== System turn Off procedures =====
 +
 +  * Transfer your data to the institutional server (data is deleted every 3 months)
 +  * Clean up immersion objective(s)
 +  * Remove all your samples and accessories and leave the working area ready for the next user
  
 If there is another user for this microscope in the __next hour__: If there is another user for this microscope in the __next hour__:
-  * Leave the fluorescent lamp and lasers on +  * Leave the fluorescent lamp and LASER "​ON"​ 
-  * Clean up immersion objectives+  * Inform staff you are leaving the system "​ON"​ 
 + 
 Else: Else:
-  * Clean up objective(s+  * Set the LASER to "​Standby" ​(LASER key to the left
-  * Set the laser to ''​standby''​ +  * Turn "​OFF"​ all pre-amps (make sure to protect 1st for Ch1&2! 
-  * ...+  * Turn "​OFF"​ the fluorescence lamp 
 +  * Turn "​OFF"​ monitor, lights, and close the microscope curtains 
 +  * Make sure you turn "​OFF"​ any life support unit used (heating, CO2, O2...)
  
 ---- ----