deltavision
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| deltavision [2026/08/11 01:56] – bioimaging | deltavision [2026/11/17 10:36] (current) – bioimaging | ||
|---|---|---|---|
| Line 33: | Line 33: | ||
| ==== Lasers ==== | ==== Lasers ==== | ||
| - | ^ Excitation | + | |
| - | | | + | < |
| - | | | + | |
| - | | | + | < |
| - | | | + | table.centered th, |
| + | table.centered td { text-align: center; vertical-align: | ||
| + | </ | ||
| + | |||
| + | <table class=" | ||
| + | < | ||
| + | < | ||
| + | < | ||
| + | <th>Wavelength</ | ||
| + | <th>Power</ | ||
| + | </ | ||
| + | </ | ||
| + | | ||
| + | < | ||
| + | <td>Violet</td> | ||
| + | < | ||
| + | <td>100mW</td> | ||
| + | </ | ||
| + | < | ||
| + | <td>Blue</td> | ||
| + | < | ||
| + | <td>100mW</td> | ||
| + | </ | ||
| + | < | ||
| + | <td>Yellow-Green< | ||
| + | < | ||
| + | <td>100mW</td> | ||
| + | </ | ||
| + | < | ||
| + | <td>Red</td> | ||
| + | < | ||
| + | <td>100mW</ | ||
| + | </ | ||
| + | </ | ||
| + | </ | ||
| + | </ | ||
| ==== Objectives ==== | ==== Objectives ==== | ||
| - | ^ | + | |
| - | | <fc # | + | < |
| - | | | + | <table class=" |
| + | < | ||
| + | < | ||
| + | <th>Magnification</ | ||
| + | <th>Model</ | ||
| + | <th>Immersion</ | ||
| + | <th>NA</ | ||
| + | <th>WD (mm)</ | ||
| + | <th>Image Pixel Size</ | ||
| + | </ | ||
| + | </ | ||
| + | <tbody> | ||
| + | < | ||
| + | < | ||
| + | <td>UPlan SAPO</ | ||
| + | <td>-</ | ||
| + | <td>0.75</ | ||
| + | <td>0.6</ | ||
| + | <td>0.240</td> | ||
| + | </tr> | ||
| + | < | ||
| + | < | ||
| + | <td>Plan APO N</ | ||
| + | <td>Oil</ | ||
| + | <td>1.42</ | ||
| + | <td>0.15</ | ||
| + | <td>0.080*</ | ||
| + | </ | ||
| + | </ | ||
| + | </ | ||
| + | </ | ||
| * after SIM reconstruction this system is capable of achieving resolutions of 100-150nm! | * after SIM reconstruction this system is capable of achieving resolutions of 100-150nm! | ||
| Line 48: | Line 113: | ||
| ==== Emission filters ==== | ==== Emission filters ==== | ||
| - | ^ | + | < |
| - | | | + | <table class=" |
| - | | | + | < |
| - | | | + | < |
| - | | | + | <th>Channel</ |
| - | | | + | <th>Wavelength</ |
| + | <th>Camera</ | ||
| + | </ | ||
| + | </ | ||
| + | | ||
| + | < | ||
| + | <td>DAPI</td> | ||
| + | < | ||
| + | <td>1</td> | ||
| + | </ | ||
| + | < | ||
| + | <td>GFP</td> | ||
| + | < | ||
| + | <td>1</ | ||
| + | </tr> | ||
| + | < | ||
| + | <td>RFP</td> | ||
| + | < | ||
| + | <td>2</td> | ||
| + | </ | ||
| + | < | ||
| + | <td>Cy5</td> | ||
| + | < | ||
| + | <td>2</td> | ||
| + | </ | ||
| + | < | ||
| + | <td>Brightfield / DIC*</ | ||
| + | <td>-</ | ||
| + | <td>1/2</ | ||
| + | </ | ||
| + | </ | ||
| + | </ | ||
| + | </ | ||
| * though possible, DIC imaging is not recommended as it may introduce artifacts in the fluorescence reconstructions | * though possible, DIC imaging is not recommended as it may introduce artifacts in the fluorescence reconstructions | ||
deltavision.txt · Last modified: by bioimaging