User Tools

Site Tools


blaze

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
blaze [2026/02/17 17:09]
bioimaging [Fluorescence filters]
blaze [2026/05/26 11:47] (current)
bioimaging [Microscope Turn On Procedure]
Line 55: Line 55:
 ===== Objectives ===== ===== Objectives =====
 ^  Magnification ​ ^  Dipping caps RI range ^  NA  ^  WD per dipping cap (mm)  ^  Maximum Theoretical Resolution (um)  ^ ^  Magnification ​ ^  Dipping caps RI range ^  NA  ^  WD per dipping cap (mm)  ^  Maximum Theoretical Resolution (um)  ^
-|  1.1x  |  1.33-1.49 / 1.50-1.57 ​ |  0.1  |  16 / 17.6  |  4.8  | +|  ​<fc #88888a>1.1x</​fc> ​ ​| ​ 1.33-1.49 / 1.50-1.57 ​ |  0.1  |  16 / 17.6  |  4.8  | 
-|  4x  |  1.33-1.41 / 1.42-1.48 / 1.49-1.57 ​ |  0.35  |  >=15 / >=15 / >​=15 ​ |  1.3  | +|  ​<fc #df2b37>4x</​fc> ​ ​| ​ 1.33-1.41 / 1.42-1.48 / 1.49-1.57 ​ |  0.35  |  >=15 / >=15 / >​=15 ​ |  1.3  | 
-|  12x  |  1.33-1.41 / 1.42-1.48 / 1.49-1.57 ​ |  0.55  |  8.5 / 10.9 / 10  |  0.5  |+|  ​<fc #fef042>12x</​fc> ​ ​| ​ 1.33-1.41 / 1.42-1.48 / 1.49-1.57 ​ |  0.55  |  8.5 / 10.9 / 10  |  0.5  |
  
 ===== Objectives + Zoom ===== ===== Objectives + Zoom =====
-^  Objective ​ ^  Zoom  ^  Final Magnification ​ ​^ ​ Field of view (mm)  ^ +^  Objective ​ ^  Zoom  ^  Final Magnification ​ ^ 
-|  1.1x  |  0.6x  |  0.66x  ​|    ​+|  ​<fc #88888a>1.1x</​fc> ​ ​| ​ 0.6x  |  0.66x  | 
-|  1.1x  |  1x  |  1.1x  ​|    ​+|  ​<fc #88888a>1.1x</​fc> ​ ​| ​ 1x  |  1.1x  | 
-|  1.1x  |  1.66x  |  ~1.83x  ​|    ​+|  ​<fc #88888a>1.1x</​fc> ​ ​| ​ 1.66x  |  ~1.83x ​ | 
-|  1.1x  |  2.5x  |  2.75x  ​|    ​+|  ​<fc #88888a>1.1x</​fc> ​ ​| ​ 2.5x  |  2.75x  | 
-|  4x  |  0.6x  |  2.4x  ​|    ​+|  ​<fc #df2b37>4x</​fc> ​ ​| ​ 0.6x  |  2.4x  | 
-|  4x  |  1x  |  4x  ​|    ​+|  ​<fc #df2b37>4x</​fc> ​ ​| ​ 1x  |  4x  | 
-|  4x  |  1.66x  |  6.64x  ​|    ​+|  ​<fc #df2b37>4x</​fc> ​ ​| ​ 1.66x  |  6.64x  | 
-|  4x  |  2.5x  |  10x  ​|    ​+|  ​<fc #df2b37>4x</​fc> ​ ​| ​ 2.5x  |  10x  | 
-|  12x  |  0.6x  |  7.2x  ​|    ​+|  ​<fc #fef042>12x</​fc> ​ ​| ​ 0.6x  |  7.2x  | 
-|  12x  |  1x  |  12x  ​|    ​+|  ​<fc #fef042>12x</​fc> ​ ​| ​ 1x  |  12x  | 
-|  12x  |  1.66x  |  19.92x  ​|    ​+|  ​<fc #fef042>12x</​fc> ​ ​| ​ 1.66x  |  19.92x ​ | 
-|  12x  |  2.5x  |  30x  ​|    ​|+|  ​<fc #fef042>12x</​fc> ​ ​| ​ 2.5x  |  30x  |
  
 ===== Camera ===== ===== Camera =====
Line 82: Line 82:
 ===== Microscope Turn On Procedure ===== ===== Microscope Turn On Procedure =====
   * Turn on the power bar on **top of the microscope'​s computer**, under the table.   * Turn on the power bar on **top of the microscope'​s computer**, under the table.
 +  * 
 +  * Start the workstation. Booting will take a long time, and will only beep and turn the "​ON"​ light after 2-3min - be patient! ​
  
 ===== Microscope Turn Off Procedure ===== ===== Microscope Turn Off Procedure =====
blaze.1771344579.txt.gz · Last modified: 2026/02/17 17:09 by bioimaging