User Tools

Site Tools


agilent_cytation_5

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
agilent_cytation_5 [2026/03/02 13:48]
bioimaging
agilent_cytation_5 [2026/08/05 15:41] (current)
bioimaging [Filtersets available]
Line 33: Line 33:
  
 It is also equipped with an atmosphere control unit for regulating CO2 concentration (for live cell imaging), and capable of setting up for hypoxia conditions also. The multimode detection modules include filter- and monochromator-based fluorescence detection, luminescence,​ and UV-Vis absorbance detection. It is also equipped with an atmosphere control unit for regulating CO2 concentration (for live cell imaging), and capable of setting up for hypoxia conditions also. The multimode detection modules include filter- and monochromator-based fluorescence detection, luminescence,​ and UV-Vis absorbance detection.
- 
-===== System Calendar ===== 
- 
-Go to Agendo for the most up to date information! 
- 
-<​html>​ 
-<iframe src="​https://​calendar.google.com/​calendar/​embed?​height=600&​wkst=2&​ctz=Europe%2FDublin&​showNav=0&​showPrint=0&​showTabs=0&​mode=WEEK&​showTz=0&​showCalendars=0&​title=%5BOeiras%5D%20Agilent%20Cytation%205&​src=YTduazR0djVmNTVkaWRhbGo1dGxxMXI2MzQ3dmU5ajhAaW1wb3J0LmNhbGVuZGFyLmdvb2dsZS5jb20&​color=%238e24aa"​ style="​border-width:​0"​ width="​1000"​ height="​550"​ frameborder="​0"​ scrolling="​no"></​iframe>​ 
-</​html>​ 
  
 ===== System Components ===== ===== System Components =====
Line 60: Line 52:
 |  -  |  GFP  |  453-488 nm  |  497 nm  |  <fc #​4aff00>​505-545 nm</​fc> ​ |[[https://​www.agilent.com/​store/​en_US/​Prod-1225101/​1225101|1225101]] ​ | |  -  |  GFP  |  453-488 nm  |  497 nm  |  <fc #​4aff00>​505-545 nm</​fc> ​ |[[https://​www.agilent.com/​store/​en_US/​Prod-1225101/​1225101|1225101]] ​ |
 |  3  |  Propidium Iodide ​ |  511-551 nm  |  605  nm  |  <fc #​ff0000>​619-676 nm</​fc> ​ |[[https://​www.agilent.com/​store/​en_US/​Prod-1225111/​1225111|1225111]] ​ | |  3  |  Propidium Iodide ​ |  511-551 nm  |  605  nm  |  <fc #​ff0000>​619-676 nm</​fc> ​ |[[https://​www.agilent.com/​store/​en_US/​Prod-1225111/​1225111|1225111]] ​ |
-|  ​ ​| ​ Texas Red  |  579-594 nm  |  605 nm  |  <fc #​ff0000>​619-676 nm</​fc> ​ |  [[https://​www.agilent.com/​store/​en_US/​Prod-1225102/​1225102|1225102]] ​ | +|  ​ ​| ​ Texas Red  |  579-594 nm  |  605 nm  |  <fc #​ff0000>​619-676 nm</​fc> ​ |  [[https://​www.agilent.com/​store/​en_US/​Prod-1225102/​1225102|1225102]] ​ | 
-|  ​ ​| ​ Cy5  |  608-648 nm  |  660 nm  |  <fc #​ff0000>​665-705 nm</​fc> ​ |  [[https://​www.agilent.com/​store/​en_US/​Prod-1225105/​|1225105]] ​ |+|  ​ ​| ​ Cy5  |  608-648 nm  |  660 nm  |  <fc #​ff0000>​665-705 nm</​fc> ​ |  [[https://​www.agilent.com/​store/​en_US/​Prod-1225105/​|1225105]] ​ |
  
 ==== Objectives ==== ==== Objectives ====
agilent_cytation_5.1772455720.txt.gz · Last modified: 2026/03/02 13:48 by bioimaging