 <​b>​Software</​b>:​ Gen 5 Image Prime <br> <​b>​Software</​b>:​ Gen 5 Image Prime <br>
 <​b>​Year</​b>:​ 2024 <br> <​b>​Year</​b>:​ 2024 <br>
-<​b>​SN</​b>: ​ <br>+<​b>​SN</​b>: ​JDGD GHWD HGWM KH<br>
 &nbsp <br> &nbsp <br>
 Data will be deleted after: <b>1 month</​b>​ Data will be deleted after: <b>1 month</​b>​
Line 37: Line 37:
 ===== Filtersets available ===== ===== Filtersets available =====
  
-^  Default Config ​ ^  Filterset ​ ^  Filterset Reference ​ ^  LED wavelength (nm)  ^  LED reference ​ ^  Excitation (nm)  ^  Dichroic (nm)  ^  Emission (nm)  ​^ ​ Default Config ​ ^+^  Default Config ​ ^  Filterset ​ ^  Filterset Reference ​ ^  LED wavelength (nm)  ^  LED reference ​ ^  Excitation (nm)  ^  Dichroic (nm)  ^  Emission (nm)  ^
 |  Pos 1  |  Laser Autofocus ​ |  [[https://​www.agilent.com/​store/​productDetail.jsp?​catalogId=1225010&​catId=SubCat2ECS_2041516|1225010]] ​ |  -  |  -  |  -  |  -  |  -  | |  Pos 1  |  Laser Autofocus ​ |  [[https://​www.agilent.com/​store/​productDetail.jsp?​catalogId=1225010&​catId=SubCat2ECS_2041516|1225010]] ​ |  -  |  -  |  -  |  -  |  -  |
 |  Pos 2  |  DAPI  |  [[https://​www.agilent.com/​store/​en_US/​Prod-1225100/​1225100|1225100]] ​ |  365  |  1225007 ​ |  377/​50 ​ |  409  |  447/​60 ​ | |  Pos 2  |  DAPI  |  [[https://​www.agilent.com/​store/​en_US/​Prod-1225100/​1225100|1225100]] ​ |  365  |  1225007 ​ |  377/​50 ​ |  409  |  447/​60 ​ |
Line 59: Line 59:
  
  
-===== CO2/O2 Control Procedure  ​=====+===== Pixel Size =====
  
-  ​* **If you require CO2/O2 control**, turn the **atmosphere controller ON**.+Images coming from the Cytation 5 are not calibrated, even though the system has that information available. In the images'​ metadata you can find the PixelWidth and the ImageWidthMicrons,​ and by dividing the latter for the first, you get the Pixel Size to calibrate your images. 
 +You can find this information below, per objective and Field Of View (FOV): 
 + 
 +^  Objective ​ ^  FOV  ^  Image Size (pixels) ​ ^  Image Size (microns) ​ ^  Pixel Size (microns) ​ ^ 
 +|  4x  |  Full  |  1992 x 1992  |  3474 x 3474  |  ~1.7440 x ~1.7440 ​ | 
 +|  4x  |  75%  |  1496 x 1496  |  2609 x 2609  |  ~1.7440 x ~1.7440 ​ | 
 +|  4x  |  Standard ​ |  1224 x 904  |  2135 x 1576  |  ~1.7443 x ~1.7434 ​ | 
 +|  20x  |  Full  |  1992 x 1992  |  694 x 694  |  ~0.3484 x ~0.3484 ​ | 
 +|  20x  |  75%  |  1496 x 1496  |  521 x 521  |  ~0.3483 x ~0.3483 ​ | 
 +|  20x  |  Standard ​ |  1224 x 904  |  427 x 315  |  ~0.3489 x ~0.3485 ​ | 
 +|  40x  |  Full  |  1992 x 1992  |  347 x 347  |  ~0.1742 x ~0.1742 ​ | 
 +|  40x  |  75%  |  1496 x 1496  |  260 x 260  |  ~0.1738 x ~0.1738 ​ | 
 +|  40x  |  Standard ​ |  1224 x 904  |  213 x 157  |  ~0.1740 x ~0.1737 ​ | 
 + 
 + 
 +===== CO2 and/or O2 Control Procedure ​ ===== 
 + 
 +  ​* **If you require CO2 and/or O2 control**, turn the **atmosphere controller ON**.
 {{cytation_gas_1.png?​200|}} {{cytation_gas_1.png?​200|}}
-  * Confirm the **CO2/O2 switch is ON**, and set to the desired percentage. +  * Confirm the **CO2 and/or O2 switch is ON**, and set to the desired percentage. 
-{{cytation_gas_2.png?​200|}} +{{cytation_gas_2.png?​600|}} 
-  * **Open the CO2/N2 tap** on the wall.+  * **Open the CO2 and/or N2 tap** on the wall.
 {{cytation_gas_3.png?​200|}} {{cytation_gas_3.png?​200|}}
  