agilent_cytation_5 [2025/01/08 16:14]
bioimaging [Camera]
agilent_cytation_5 [2025/03/10 16:45] (current)
bioimaging
Line 12: Line 12:
 <​b>​Software</​b>:​ Gen 5 Image Prime <br> <​b>​Software</​b>:​ Gen 5 Image Prime <br>
 <​b>​Year</​b>:​ 2024 <br> <​b>​Year</​b>:​ 2024 <br>
-<​b>​SN</​b>: ​ <br>+<​b>​SN</​b>: ​JDGD GHWD HGWM KH<br>
 &nbsp <br> &nbsp <br>
 Data will be deleted after: <b>1 month</​b>​ Data will be deleted after: <b>1 month</​b>​
Line 37: Line 37:
 ===== Filtersets available ===== ===== Filtersets available =====
  
-^  Default Config ​ ^  Filterset ​ ^  Filterset Reference ​ ^  LED wavelength (nm)  ^  LED reference ​ ^  Excitation (nm)  ^  Dichroic (nm)  ^  Emission (nm)  ​^ ​ Default Config ​ ^+^  Default Config ​ ^  Filterset ​ ^  Filterset Reference ​ ^  LED wavelength (nm)  ^  LED reference ​ ^  Excitation (nm)  ^  Dichroic (nm)  ^  Emission (nm)  ^
 |  Pos 1  |  Laser Autofocus ​ |  [[https://​www.agilent.com/​store/​productDetail.jsp?​catalogId=1225010&​catId=SubCat2ECS_2041516|1225010]] ​ |  -  |  -  |  -  |  -  |  -  | |  Pos 1  |  Laser Autofocus ​ |  [[https://​www.agilent.com/​store/​productDetail.jsp?​catalogId=1225010&​catId=SubCat2ECS_2041516|1225010]] ​ |  -  |  -  |  -  |  -  |  -  |
 |  Pos 2  |  DAPI  |  [[https://​www.agilent.com/​store/​en_US/​Prod-1225100/​1225100|1225100]] ​ |  365  |  1225007 ​ |  377/​50 ​ |  409  |  447/​60 ​ | |  Pos 2  |  DAPI  |  [[https://​www.agilent.com/​store/​en_US/​Prod-1225100/​1225100|1225100]] ​ |  365  |  1225007 ​ |  377/​50 ​ |  409  |  447/​60 ​ |
Line 59: Line 59:
  
  
 +===== Pixel Size =====
  
 +Images coming from the Cytation 5 are not calibrated, even though the system has that information available. In the images'​ metadata you can find the PixelWidth and the ImageWidthMicrons,​ and by dividing the latter for the first, you get the Pixel Size to calibrate your images.
 +You can find this information below, per objective and Field Of View (FOV):
  
 +^  Objective ​ ^  FOV  ^  Image Size (pixels) ​ ^  Image Size (microns) ​ ^  Pixel Size (microns) ​ ^
 +|  4x  |  Full  |  1992 x 1992  |  3474 x 3474  |  ~1.7440 x ~1.7440 ​ |
 +|  4x  |  75%  |  1496 x 1496  |  2609 x 2609  |  ~1.7440 x ~1.7440 ​ |
 +|  4x  |  Standard ​ |  1224 x 904  |  2135 x 1576  |  ~1.7443 x ~1.7434 ​ |
 +|  20x  |  Full  |  1992 x 1992  |  694 x 694  |  ~0.3484 x ~0.3484 ​ |
 +|  20x  |  75%  |  1496 x 1496  |  521 x 521  |  ~0.3483 x ~0.3483 ​ |
 +|  20x  |  Standard ​ |  1224 x 904  |  427 x 315  |  ~0.3489 x ~0.3485 ​ |
 +|  40x  |  Full  |  1992 x 1992  |  347 x 347  |  ~0.1742 x ~0.1742 ​ |
 +|  40x  |  75%  |  1496 x 1496  |  260 x 260  |  ~0.1738 x ~0.1738 ​ |
 +|  40x  |  Standard ​ |  1224 x 904  |  213 x 157  |  ~0.1740 x ~0.1737 ​ |
  
  
-===== CO2/O2 Control Procedure ​ =====+===== CO2 and/or O2 Control Procedure ​ =====
  
-  * **If you require CO2/O2 control**, turn the **atmosphere controller ON**. +  * **If you require CO2 and/or O2 control**, turn the **atmosphere controller ON**. 
-{{cytation_gas_1.png?​|}} +{{cytation_gas_1.png?​200|}} 
-  * Confirm the **CO2/O2 switch is ON**, and set to the desired percentage. +  * Confirm the **CO2 and/or O2 switch is ON**, and set to the desired percentage. 
-{{cytation_gas_2.png?​|}} +{{cytation_gas_2.png?​600|}} 
-  * **Open the CO2/N2 tap** on the wall. +  * **Open the CO2 and/or N2 tap** on the wall. 
-{{cytation_gas_3.png?​|}}+{{cytation_gas_3.png?​200|}}
  
  
Line 76: Line 89:
  
   * Turn on the microscope using the **switch** at the **front of the system**.   * Turn on the microscope using the **switch** at the **front of the system**.
-{{cytation_turnon_1.png?​|}}+{{cytation_turnon_1.png?​200|}}
   * Turn the **computer** on.   * Turn the **computer** on.
-{{cytation_turnon_2.png?​|}}+{{cytation_turnon_2.png?​200|}}
   * **Login** to Windows with your **GIMM Agendo credentials**.   * **Login** to Windows with your **GIMM Agendo credentials**.
  
   * Wait for the **button light** in the front to **turn green** (the system will pop out the plate drawer as well).   * Wait for the **button light** in the front to **turn green** (the system will pop out the plate drawer as well).
-{{cytation_turnon_3.png?​|}}+{{cytation_turnon_3.png?​200|}}
   * Open the **Gen 5** software.   * Open the **Gen 5** software.
  
Line 89: Line 102:
  
   * Turn off the microscope using the **switch** at the **front of the system**.   * Turn off the microscope using the **switch** at the **front of the system**.
-{{cytation_turnon_1.png?​|}}+{{cytation_turnon_1.png?​200|}}
   * **Sign out** of the computer.   * **Sign out** of the computer.
  
   * **If you used the gas controller** ​   * **If you used the gas controller** ​
     * Turn gas controller OFF     * Turn gas controller OFF
-{{cytation_gas_1.png?​|}}+{{cytation_gas_1.png?​200|}}
     * Close all wall taps.     * Close all wall taps.
-{{cytation_gas_3.png?​|}}+{{cytation_gas_3.png?​200|}}
  
 ---- ----
 [[resources|Back to the Equipment page]] [[resources|Back to the Equipment page]]
agilent_cytation_5.1736349293.txt.gz · Last modified: 2025/01/08 16:14 by bioimaging