zeiss_cell_observer [2022/09/01 15:03]
bioimaging
zeiss_cell_observer [2024/01/28 12:13]
bioimaging [Microscope overview]
Line 14: Line 14:
 <​b>​SN</​b>:​ 3851002396<​br>​ <​b>​SN</​b>:​ 3851002396<​br>​
 &nbsp <br> &nbsp <br>
 +Data will be deleted after: <b>15 days</​b>​
 &nbsp <br> &nbsp <br>
 &nbsp <br> &nbsp <br>
Line 27: Line 28:
  
 ===== Microscope overview ===== ===== Microscope overview =====
-{{  :​widefield_lightpath.png?​0x300}}The Zeiss Cell Observer is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging with fast acquisition speeds. It is equipped with a large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. The stage is furthermore equipped with a piezo for fast Z displacement. You can choose between a HXP metal halide lamp or fast-switching LEDs for illumination. Its sensitive cooled Axiocam 506m camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples. You can also perform Z-stack acquisition and use [[https://​huygens.i3s.up.pt/​login.php|PPBI Huygens RM]] [[http://​micro.magnet.fsu.edu/​primer/​digitalimaging/​deconvolution/​deconvolutionhome.html|deconvolution]] server to significantly improve image resolution even in thick samples. If don't want to use deconvolution,​ check out one of the confocal systems such as the point scanners [[zeiss_lsm_710|Zeiss LSM 710]] and [[zeiss_lsm_880|Zeiss LSM 880]] or spinning disks [[3i_marianas_sdc|3i Marianas SDC]] and [[zeiss_cell_observer_sd|Zeiss Cell Observer SD]]. If your personal computer cannot handle all the data you collected, check out the [[colossus|Colossus]].+{{  :​widefield_lightpath.png?​0x300}}The Zeiss Cell Observer is a fully motorized inverted //widefield fluorescence microscope//​ ideal for live-cell imaging with fast acquisition speeds. It is equipped with a large cage incubator and a stage top incubator for temperature control and CO2 supply and with Definite Focus for hardware focus control during long time-lapse acquisitions. Using the ZEN software you can control the motorized filters, shutters and stage to simultaneously set up multi-color time-lapse imaging experiments in multiple stage positions. The stage is furthermore equipped with a piezo for fast Z displacement. You can choose between a HXP metal halide lamp or fast-switching LEDs for illumination. Its sensitive cooled Axiocam 506m camera allows you to capture weak fluorescent signals and minimize photobleaching/​photodamage in light sensitive samples.
  
-  * **Microscope**: ​[[http://​www.zeiss.com/​microscopy/​en_de/​products/​light-microscopes/​axio-observer-for-biology.html|Zeiss Axio Observer]]+  * **Microscope**:​ Zeiss Axio Observer
   * **LED Illumination**:​ [[https://​www.zeiss.com/​microscopy/​int/​products/​microscope-components/​lightsources/​colibri-7.html?​vaURL=www.zeiss.de/​colibri|Zeiss Colibri 7]]   * **LED Illumination**:​ [[https://​www.zeiss.com/​microscopy/​int/​products/​microscope-components/​lightsources/​colibri-7.html?​vaURL=www.zeiss.de/​colibri|Zeiss Colibri 7]]
   * **Camera**: [[https://​www.zeiss.com/​microscopy/​int/​products/​microscope-cameras/​axiocam-506-mono.html|Axiocam 506 mono CCD]]   * **Camera**: [[https://​www.zeiss.com/​microscopy/​int/​products/​microscope-cameras/​axiocam-506-mono.html|Axiocam 506 mono CCD]]
Line 41: Line 42:
  
 ===== System components ===== ===== System components =====
 +
 +==== LEDs  ====
 +^  Line  ^  Wavelength ​ ^
 +|  UV  |  385 nm  |
 +|  B  |  475 nm  |
 +|  G  |  555 nm  |
 +|  Y  |  590 nm  |
 +|  R  |  630 nm  |
  
 ==== Filtersets ==== ==== Filtersets ====
Line 59: Line 68:
 |  10x  |  EC Plan-Neofluar Ph1  |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420341-9911-000/​Objective-EC-Plan-Neofluar-10x-0.30-Ph1-M27|420341-9911-000]] ​ | |  10x  |  EC Plan-Neofluar Ph1  |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420341-9911-000/​Objective-EC-Plan-Neofluar-10x-0.30-Ph1-M27|420341-9911-000]] ​ |
 |  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]] ​ | |  20x  |  Plan-Apochromat ​ |  Air  |  0.80  |  0.55  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420650-9901-000/​Objective-Plan-Apochromat-20x-0.8-M27|420650-9901-000]] ​ |
-|  20x  |  EC Plan-Neofluar Ph 2  |  Air  |  0.50  |  2.00  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440341-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5-Ph2|440341-9904-000]] ​ |+|  20x  |  EC Plan-Neofluar Ph 2  |  Air  |  0.50  |  2.00  |  [[https://​www.micro shop.zeiss.com/​en/​de/​shop/​objectives/​440341-9904-000/​Objective-EC-Plan-Neofluar-20x-0.5-Ph2|440341-9904-000]] ​ |
 |  40x  |  EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420360-9900-000/​Objective-EC-Plan-Neofluar-40x-0.75-M27|420360-9900-000]] ​ | |  40x  |  EC Plan-NeoFluar ​ |  Air  |  0.75  |  0.71  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420360-9900-000/​Objective-EC-Plan-Neofluar-40x-0.75-M27|420360-9900-000]] ​ |
 |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ | |  63x  |  Plan-Apochromat DIC  |  Oil  |  1.40  |  0.19  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420782-9900-000/​Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27|420782-9900-000]] ​ |
Line 69: Line 78:
 |  5x  |  EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.50  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ | |  5x  |  EC Plan-NeoFluar ​ |  Air  |  0.16  |  18.50  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420330-9901-000/​Objective-EC-Plan-Neofluar-5x-0.16-M27|420330-9901-000]] ​ |
 |  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ | |  10x  |  EC Plan-Neofluar ​ |  Air  |  0.30  |  5.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420340-9901-000/​Objective-EC-Plan-Neofluar-10x-0.30-M27|420340-9901-000]] ​ |
 +|  25x  |  LCI Plan-Neofluar Corr DIC  |  Oil/​Glyc/​W ​ |  0.80  |  0.21  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420852-9973-000/​Objective-LCI-Plan-Neofluar-25x-0.8-Imm-Corr-DIC-M27|420852-9972-000]] ​ |
 |  40x  |  Plan-Apochromat Corr  |  Air  |  0.95  |  0.25  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/​Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]] ​ | |  40x  |  Plan-Apochromat Corr  |  Air  |  0.95  |  0.25  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​420660-9970-000/​Objective-Plan-Apochromat-40x-0.95-Corr-M27|420660-9970-000]] ​ |
 |  40x  |  Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ | |  40x  |  Plan-Neofluar Ph3  |  Oil  |  1.30  |  0.20  |  [[https://​www.micro-shop.zeiss.com/​en/​de/​shop/​objectives/​440451-9903-000/​Objective-EC-Plan-Neofluar-40x-1.30-Oil-Ph3|440451-9903-000]] ​ |
Line 88: Line 98:
 {{zeiss_axio_observer_b.jpg?​height=150|}} {{zeiss_axio_observer_b.jpg?​height=150|}}
   * Turn on the computer   * Turn on the computer
-  * Log in to Windows ​(Biomaging User).+  * Login in to Windows ​with your Agendo credentials
   * Start the **ZEN** software   * Start the **ZEN** software
   * Select HXP or LED Workspace in ZEN (top left)   * Select HXP or LED Workspace in ZEN (top left)